BECKHOFF

BECKHOFF ELX3152-0090 EtherCAT Terminal

SKU ELX3152-0090

Disponibile
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: BECKHOFF
  • Product No.: ELX3152-0090
  • Origin Germany
  • Product Type: EtherCAT Terminals
  • Payment: T/T, Western Union
  • Weight: 0.06 kg
  • Dimensions: 12 mm x 100 mm x 68 mm
  • Shipping port: Xiamen
  • Warranty: 12 months

Tags

Quantità

Product Description

Description

Directing high-precision analog measurements in hazardous environments, the ELX3152-0090 is an intrinsically safe analog input terminal designed for the direct integration of field devices from Zone 0/20 explosion-hazard areas. This 2-channel single-ended interface processes standard 0/4 to 20 mA current signals with 16-bit resolution. Integrated with TwinSAFE SC (Single Channel) technology, the terminal enables safety-supporting signals to be analyzed and utilized within standard industrial control systems, expanding diagnostic depth and process safety across complex control architectures.

Features

  • Direct connection of intrinsically safe field devices from Zone 0/20 and Zone 1/21.
  • Two independent single-ended analog input channels supporting 0 to 20 mA and 4 to 20 mA signals.
  • TwinSAFE SC capability for integrating safety-assisting monitoring functions.
  • High-resolution 16-bit representation for highly accurate field instrument monitoring.
  • Supports Distributed Clocks (DC) for highly synchronized and precise EtherCAT process data acquisition.
  • Advanced internal processing options including activatable digital FIR/IIR filters.
  • Diagnostic compliance with NE43 NAMUR sensor limit specifications.

Applications

  • Oil and gas extraction, processing, and refining facilities.
  • Chemical and petrochemical process plants requiring intrinsic safety (Ex i).
  • Industrial wastewater treatment facilities with explosive gas atmospheres.
  • Pharmaceutical processing lines managing volatile substances.

Technical Specifications

Manufacturer BECKHOFF
Part Number / Model ELX3152-0090
Product Type EtherCAT Terminal (Ex i, TwinSAFE SC)
Number of Inputs 2 (single-ended)
Signal Current Range 0/4...20 mA
Connection Technology 2- or 3-wire (default: 3-wire)
Resolution 16 bit (including sign)
Measuring Error < +/-0.3% (relative to full scale value)
Internal Measuring Resistance typ. 100 Ohm
Input Filter Limit Frequency 5 kHz
Conversion Time typ. 1 ms
Electronics Supply Voltage 24 V DC (via power contacts, powered by ELX9560)
Current Consumption (Power Contacts) typ. 10 mA + load
Current Consumption (E-bus) typ. 85 mA
Distributed Clocks (DC) Yes
Operating Temperature -25 to +60 degC
Storage Temperature -40 to +85 degC
Relative Humidity 95%, non-condensing
Weight approx. 60 g
Dimensions (W x H x D) 12 mm x 100 mm x 68 mm
Housing Material Polycarbonate

Connections and Interfaces

Connection Property Specification / Wire Size
Wiring Type Solid wire, stranded wire, or wire with ferrule (spring-actuated)
Solid Conductor (s) 0.08 to 2.5 mm² (AWG 28...14)
Stranded Conductor (st) 0.08 to 2.5 mm² (AWG 28...14)
Flexible Conductor with Ferrule (f) 0.14 to 1.5 mm² (AWG 26...16)
Stripping Length 8 to 9 mm
Power Contacts 2 blade/spring contacts

Installation Guidelines

  • Mount securely on a standard 35 mm DIN rail conforming to EN 60715 using the locking mechanism.
  • Ensure adjacent terminal modules are locked using the integrated double-slot and key housing connections.
  • Power the terminal exclusively through a certified ELX9560 power supply module to satisfy all intrinsically safe electrical isolation standards.
  • Ensure appropriate spacing and ventilation within the terminal cluster as defined by the hazardous zone class regulations.

Compliance and Certifications

  • CE, UL
  • ATEX: II 3(1)G Ex ec [ia Ga] IIC T4 Gc, II (1)D [Ex ia Da] IIIC, I (M1) [Ex ia Ma] I
  • IECEx: Ex ec [ia Ga] IIC T4 Gc, [Ex ia Da] IIIC, [Ex ia Ma] I
  • cFMus: AIS Class I, II, III, Division 1, Groups A-G; Class I, Division 2, Groups A-D; Class I, Zone 2, AEx ec [ia Ga] IIC T4 Gc
Shipping &amp; Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
FAQ
What is the primary function of the Beckhoff ELX3152-0090?
The Beckhoff ELX3152-0090 is a 2-channel analog input EtherCAT Terminal that allows direct measurement of 0/4 to 20 mA current loops from intrinsically safe (Ex i) sensors located in Zone 0/20 and Zone 1/21 hazardous areas.
What is TwinSAFE SC technology and how is it used in this module?
TwinSAFE SC (Single Channel) technology allows analog process values from standard terminals like the ELX3152-0090 to be made available to safety-related networks (TwinSAFE) for auxiliary safety functions, without requiring dedicated, certified safety-only hardware.
What power supply is required for the ELX3152-0090 terminal?
The terminal requires 24 V DC power delivered via the power contacts from an ELX9560 power supply terminal. This ensures compliance with intrinsically safe barrier regulations and appropriate signal isolation.
Reviews

ELX3152-0090

Stock &amp; lead time on request

Call
1 su 1

BECKHOFF ELX3152-0090 EtherCAT Terminal

Only 10 item(s) left in stock
  • Manufacturer: BECKHOFF

  • Product No.: ELX3152-0090

  • Country of origin:Germany

  • Product Type: EtherCAT Terminals

  • Payment: T/T, Western Union

  • Weight: 60g

  • Dimensions: 12 mm x 100 mm x 68 mm

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantità
Visualizza dettagli completi

Product Description

Description

Directing high-precision analog measurements in hazardous environments, the ELX3152-0090 is an intrinsically safe analog input terminal designed for the direct integration of field devices from Zone 0/20 explosion-hazard areas. This 2-channel single-ended interface processes standard 0/4 to 20 mA current signals with 16-bit resolution. Integrated with TwinSAFE SC (Single Channel) technology, the terminal enables safety-supporting signals to be analyzed and utilized within standard industrial control systems, expanding diagnostic depth and process safety across complex control architectures.

Features

  • Direct connection of intrinsically safe field devices from Zone 0/20 and Zone 1/21.
  • Two independent single-ended analog input channels supporting 0 to 20 mA and 4 to 20 mA signals.
  • TwinSAFE SC capability for integrating safety-assisting monitoring functions.
  • High-resolution 16-bit representation for highly accurate field instrument monitoring.
  • Supports Distributed Clocks (DC) for highly synchronized and precise EtherCAT process data acquisition.
  • Advanced internal processing options including activatable digital FIR/IIR filters.
  • Diagnostic compliance with NE43 NAMUR sensor limit specifications.

Applications

  • Oil and gas extraction, processing, and refining facilities.
  • Chemical and petrochemical process plants requiring intrinsic safety (Ex i).
  • Industrial wastewater treatment facilities with explosive gas atmospheres.
  • Pharmaceutical processing lines managing volatile substances.

Technical Specifications

Manufacturer BECKHOFF
Part Number / Model ELX3152-0090
Product Type EtherCAT Terminal (Ex i, TwinSAFE SC)
Number of Inputs 2 (single-ended)
Signal Current Range 0/4...20 mA
Connection Technology 2- or 3-wire (default: 3-wire)
Resolution 16 bit (including sign)
Measuring Error < +/-0.3% (relative to full scale value)
Internal Measuring Resistance typ. 100 Ohm
Input Filter Limit Frequency 5 kHz
Conversion Time typ. 1 ms
Electronics Supply Voltage 24 V DC (via power contacts, powered by ELX9560)
Current Consumption (Power Contacts) typ. 10 mA + load
Current Consumption (E-bus) typ. 85 mA
Distributed Clocks (DC) Yes
Operating Temperature -25 to +60 degC
Storage Temperature -40 to +85 degC
Relative Humidity 95%, non-condensing
Weight approx. 60 g
Dimensions (W x H x D) 12 mm x 100 mm x 68 mm
Housing Material Polycarbonate

Connections and Interfaces

Connection Property Specification / Wire Size
Wiring Type Solid wire, stranded wire, or wire with ferrule (spring-actuated)
Solid Conductor (s) 0.08 to 2.5 mm² (AWG 28...14)
Stranded Conductor (st) 0.08 to 2.5 mm² (AWG 28...14)
Flexible Conductor with Ferrule (f) 0.14 to 1.5 mm² (AWG 26...16)
Stripping Length 8 to 9 mm
Power Contacts 2 blade/spring contacts

Installation Guidelines

  • Mount securely on a standard 35 mm DIN rail conforming to EN 60715 using the locking mechanism.
  • Ensure adjacent terminal modules are locked using the integrated double-slot and key housing connections.
  • Power the terminal exclusively through a certified ELX9560 power supply module to satisfy all intrinsically safe electrical isolation standards.
  • Ensure appropriate spacing and ventilation within the terminal cluster as defined by the hazardous zone class regulations.

Compliance and Certifications

  • CE, UL
  • ATEX: II 3(1)G Ex ec [ia Ga] IIC T4 Gc, II (1)D [Ex ia Da] IIIC, I (M1) [Ex ia Ma] I
  • IECEx: Ex ec [ia Ga] IIC T4 Gc, [Ex ia Da] IIIC, [Ex ia Ma] I
  • cFMus: AIS Class I, II, III, Division 1, Groups A-G; Class I, Division 2, Groups A-D; Class I, Zone 2, AEx ec [ia Ga] IIC T4 Gc

What is the primary function of the Beckhoff ELX3152-0090?

The Beckhoff ELX3152-0090 is a 2-channel analog input EtherCAT Terminal that allows direct measurement of 0/4 to 20 mA current loops from intrinsically safe (Ex i) sensors located in Zone 0/20 and Zone 1/21 hazardous areas.

What is TwinSAFE SC technology and how is it used in this module?

TwinSAFE SC (Single Channel) technology allows analog process values from standard terminals like the ELX3152-0090 to be made available to safety-related networks (TwinSAFE) for auxiliary safety functions, without requiring dedicated, certified safety-only hardware.

What power supply is required for the ELX3152-0090 terminal?

The terminal requires 24 V DC power delivered via the power contacts from an ELX9560 power supply terminal. This ensures compliance with intrinsically safe barrier regulations and appropriate signal isolation.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Technical knowledge

1756-L73 Firmware Upgrade Guide: v19 vs v21/v31 Decision

Replacing a 1756-L73 does not automatically mean upgrading its firmware. This guide compares v19.013, v21.011 and v31.011, focusing on project compatibility, HMI communications, legacy networks and...

Implementing 3-Switch XOR Ladder Logic with Internal Bit

Implement a 3-SPST switch XOR light circuit in LogixPro or RSLogix 500 using an internal relay bit. Includes truth tables, boolean equations, and verified.

Building a Modbus RTU Network with CompactLogix and DeltaV

Integrate Allen-Bradley CompactLogix, Caterpillar ATS, and generators into DeltaV DCS over Modbus RTU. Covers ProSoft MVI69-MCM, Miille DIN266 gateways.

ONS Instruction Not Energizing OTE in Studio 5000 Ladder Logic

ONS instruction fires but the OTE coil never latches in Studio 5000 because the one-shot is only true for one scan. Use OTL/OTU or seal-in logic instead.

Kinetix 5500 EtherNet/IP Network Switch Requirements and Topology

Configure Allen-Bradley Kinetix 5500 servo drives on EtherNet/IP. Covers CIP Sync, IEEE 1588 V2 timing, Stratix selection, DLR topology, and HMI.

Moving Average Filtering in DCS and PLC Analog Control

A moving-average filter is the sliding-window smoother most instrument engineers drop into DCS and PLC analog paths. Here is how the window works, how N and sample time set lag, and when a...