Description

The BECKHOFF IP3312-B200 is a modular Fieldbus Box designed for decentralized industrial automation tasks. This device integrates directly into harsh industrial environments without requiring a control cabinet, utilizing a high protection rating to ensure reliable operation close to the machine level. As part of the BECKHOFF decentralized I/O product range, it processes peripheral signals and communicates over a specific fieldbus interface, providing flexible signal collection and distribution for automated manufacturing and process systems.

Engineered for decentralized machine architectures, the unit connects local digital or analog peripheral signals and interfaces directly with higher-level control systems via fiber-optic communication lines. The IP3312-B200 supports configuration via the KS2000 software tool or directly through the connected controller, allowing efficient setup and diagnostic management in distributed topologies.

Features

  • Decentralized Fieldbus Box architecture designed for machine-level installation without control cabinets
  • Bus interface featuring two fiber-optic sockets for robust data transmission
  • Data transfer rate of 2.5 Mbaud
  • Configurable via the KS2000 software configuration tool or the master controller
  • Control voltage supply rated at 24 V DC with reverse polarity protection tolerances
  • M8 connector layout for power supply feed and downstream power connections
  • High environmental protection rating suitable for demanding industrial conditions

Applications

  • Decentralized signal acquisition and control in automated manufacturing lines
  • Machine-mounted industrial automation systems requiring cabinet-free I/O distribution
  • Conveyor and material handling systems utilizing fiber-optic network topologies
  • Special-purpose machinery requiring high dust and moisture resistance

Technical Specifications

General

Parameter Specification
Manufacturer BECKHOFF
Exact Model IP3312-B200
Product Type Fieldbus Box
Extension Modules Not applicable
Country of Origin Germany

Communication and Data

Parameter Specification
Bus Interface 2 x fiber-optic socket for plug ZS1020-0010
Data Transfer Rates 2.5 Mbaud
Configuration Possibility Via KS2000 or the controller

Electrical Characteristics

Parameter Specification
Control Voltage Power Supply 24 V DC (-15 percent / +20 percent)
Load Voltage Power Supply According to I/O type
Power Supply Connection (Feed) 1 x M8 male socket, 4-pin
Power Supply Connection (Downstream) 1 x M8 female socket, 4-pin
Auxiliary Power Current According to I/O type
Electrical Isolation Control voltage/fieldbus: yes; control voltage/inputs or outputs: according to I/O type

Mechanical and Environmental

Parameter Specification
Protection Rating IP65, IP66, IP67 (conforms to EN 60529)
Installation Position Variable
Operating Temperature Range 0 to +55 degC
Storage Temperature Range -25 to +85 degC
Vibration Resistance Conforms to EN 60068-2-6
Shock Resistance Conforms to EN 60068-2-27
EMC Immunity Conforms to EN 61000-6-2
EMC Emission Conforms to EN 61000-6-4
Weight Approx. 250 g
Approvals and Markings CE, UL

Installation Guidelines

  1. Verify that the exact model IP3312-B200 matches your system requirements and physical mounting layout.
  2. Ensure all power supplies and connected circuits are fully de-energized before mounting or wiring the device.
  3. Inspect the module, M8 connectors, and fiber-optic sockets for any physical damage or contamination.
  4. Mount the Fieldbus Box securely onto a flat machine surface in a variable installation position appropriate for the application.
  5. Connect the 24 V DC control voltage supply to the M8 male feed socket and link downstream devices using the M8 female socket as needed.
  6. Attach the fiber-optic communication lines using compatible ZS1020-0010 plugs to establish the network connection.
  7. Check all potential relationships, signal wiring, and grounding integrity before restoring power to the system.
  8. Power on the control system and configure the device parameters via the KS2000 software or master controller.
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
FAQ
What is the primary function of the BECKHOFF IP3312-B200?
The BECKHOFF IP3312-B200 is a modular Fieldbus Box engineered for decentralized industrial automation and signal acquisition. It allows peripheral signals to be processed directly on the machine level without the need for a control cabinet. This setup significantly reduces wiring complexity in distributed manufacturing and process environments.
How does the BECKHOFF IP3312-B200 communicate with control systems?
The BECKHOFF IP3312-B200 utilizes a bus interface featuring two fiber-optic sockets designed for ZS1020-0010 plugs. It supports a reliable data transfer rate of 2.5 Mbaud over these fiber-optic lines. This ensures robust communication immune to typical industrial electromagnetic interference.
What power supply requirements does the BECKHOFF IP3312-B200 have?
The BECKHOFF IP3312-B200 operates on a control voltage power supply rated at 24 V DC, with tolerances ranging from -15 percent to +20 percent. Power is fed into the unit via a 4-pin M8 male socket, while downstream power connections are facilitated through an M8 female socket. Electrical isolation is provided between the control voltage and the fieldbus interface to enhance operational safety.
What environmental conditions can the BECKHOFF IP3312-B200 withstand?
The BECKHOFF IP3312-B200 features a high environmental protection rating of IP65, IP66, and IP67 conforming to EN 60529 standards. This makes it highly resistant to dust and moisture, allowing direct mounting in harsh factory environments. Additionally, it operates reliably within a temperature range of 0 to +55 degrees Celsius.
How is the BECKHOFF IP3312-B200 configured and set up?
The BECKHOFF IP3312-B200 can be easily configured using the KS2000 software configuration tool or directly through the connected master controller. Setup involves securing the unit to a machine surface, connecting the M8 power and fiber-optic communication lines, and verifying signal integrity. Proper configuration ensures seamless integration into automated material handling and production lines.
Reviews

IP3312-B200

Stock & lead time on request

Call
1 su 1

BECKHOFF IP3312-B200 Fieldbus Box

Only 10 item(s) left in stock
  • Manufacturer: BECKHOFF

  • Product No.: IP3312-B200

  • Country of origin:Germany

  • Product Type: Fieldbus Box

  • Payment: T/T, Western Union

  • Weight: 500g

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantità
Visualizza dettagli completi

Product Description

Description

The BECKHOFF IP3312-B200 is a modular Fieldbus Box designed for decentralized industrial automation tasks. This device integrates directly into harsh industrial environments without requiring a control cabinet, utilizing a high protection rating to ensure reliable operation close to the machine level. As part of the BECKHOFF decentralized I/O product range, it processes peripheral signals and communicates over a specific fieldbus interface, providing flexible signal collection and distribution for automated manufacturing and process systems.

Engineered for decentralized machine architectures, the unit connects local digital or analog peripheral signals and interfaces directly with higher-level control systems via fiber-optic communication lines. The IP3312-B200 supports configuration via the KS2000 software tool or directly through the connected controller, allowing efficient setup and diagnostic management in distributed topologies.

Features

  • Decentralized Fieldbus Box architecture designed for machine-level installation without control cabinets
  • Bus interface featuring two fiber-optic sockets for robust data transmission
  • Data transfer rate of 2.5 Mbaud
  • Configurable via the KS2000 software configuration tool or the master controller
  • Control voltage supply rated at 24 V DC with reverse polarity protection tolerances
  • M8 connector layout for power supply feed and downstream power connections
  • High environmental protection rating suitable for demanding industrial conditions

Applications

  • Decentralized signal acquisition and control in automated manufacturing lines
  • Machine-mounted industrial automation systems requiring cabinet-free I/O distribution
  • Conveyor and material handling systems utilizing fiber-optic network topologies
  • Special-purpose machinery requiring high dust and moisture resistance

Technical Specifications

General

Parameter Specification
Manufacturer BECKHOFF
Exact Model IP3312-B200
Product Type Fieldbus Box
Extension Modules Not applicable
Country of Origin Germany

Communication and Data

Parameter Specification
Bus Interface 2 x fiber-optic socket for plug ZS1020-0010
Data Transfer Rates 2.5 Mbaud
Configuration Possibility Via KS2000 or the controller

Electrical Characteristics

Parameter Specification
Control Voltage Power Supply 24 V DC (-15 percent / +20 percent)
Load Voltage Power Supply According to I/O type
Power Supply Connection (Feed) 1 x M8 male socket, 4-pin
Power Supply Connection (Downstream) 1 x M8 female socket, 4-pin
Auxiliary Power Current According to I/O type
Electrical Isolation Control voltage/fieldbus: yes; control voltage/inputs or outputs: according to I/O type

Mechanical and Environmental

Parameter Specification
Protection Rating IP65, IP66, IP67 (conforms to EN 60529)
Installation Position Variable
Operating Temperature Range 0 to +55 degC
Storage Temperature Range -25 to +85 degC
Vibration Resistance Conforms to EN 60068-2-6
Shock Resistance Conforms to EN 60068-2-27
EMC Immunity Conforms to EN 61000-6-2
EMC Emission Conforms to EN 61000-6-4
Weight Approx. 250 g
Approvals and Markings CE, UL

Installation Guidelines

  1. Verify that the exact model IP3312-B200 matches your system requirements and physical mounting layout.
  2. Ensure all power supplies and connected circuits are fully de-energized before mounting or wiring the device.
  3. Inspect the module, M8 connectors, and fiber-optic sockets for any physical damage or contamination.
  4. Mount the Fieldbus Box securely onto a flat machine surface in a variable installation position appropriate for the application.
  5. Connect the 24 V DC control voltage supply to the M8 male feed socket and link downstream devices using the M8 female socket as needed.
  6. Attach the fiber-optic communication lines using compatible ZS1020-0010 plugs to establish the network connection.
  7. Check all potential relationships, signal wiring, and grounding integrity before restoring power to the system.
  8. Power on the control system and configure the device parameters via the KS2000 software or master controller.
Loading product navigation…

What is the primary function of the BECKHOFF IP3312-B200?

The BECKHOFF IP3312-B200 is a modular Fieldbus Box engineered for decentralized industrial automation and signal acquisition. It allows peripheral signals to be processed directly on the machine level without the need for a control cabinet. This setup significantly reduces wiring complexity in distributed manufacturing and process environments.

How does the BECKHOFF IP3312-B200 communicate with control systems?

The BECKHOFF IP3312-B200 utilizes a bus interface featuring two fiber-optic sockets designed for ZS1020-0010 plugs. It supports a reliable data transfer rate of 2.5 Mbaud over these fiber-optic lines. This ensures robust communication immune to typical industrial electromagnetic interference.

What power supply requirements does the BECKHOFF IP3312-B200 have?

The BECKHOFF IP3312-B200 operates on a control voltage power supply rated at 24 V DC, with tolerances ranging from -15 percent to +20 percent. Power is fed into the unit via a 4-pin M8 male socket, while downstream power connections are facilitated through an M8 female socket. Electrical isolation is provided between the control voltage and the fieldbus interface to enhance operational safety.

What environmental conditions can the BECKHOFF IP3312-B200 withstand?

The BECKHOFF IP3312-B200 features a high environmental protection rating of IP65, IP66, and IP67 conforming to EN 60529 standards. This makes it highly resistant to dust and moisture, allowing direct mounting in harsh factory environments. Additionally, it operates reliably within a temperature range of 0 to +55 degrees Celsius.

How is the BECKHOFF IP3312-B200 configured and set up?

The BECKHOFF IP3312-B200 can be easily configured using the KS2000 software configuration tool or directly through the connected master controller. Setup involves securing the unit to a machine surface, connecting the M8 power and fiber-optic communication lines, and verifying signal integrity. Proper configuration ensures seamless integration into automated material handling and production lines.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Technical knowledge

Diagnosi degli alimentatori da 24 V CC senza inseguire guasti fantasma

Un quadro di controllo inattivo non significa automaticamente che l’alimentatore sia guasto. Questa guida sul campo utilizza controlli dell’ingresso, a vuoto, sotto carico, dell’ondulazione, del...

Una catena di segnali pratica per la misurazione e il controllo industriali

Un controllo affidabile inizia prima che il PLC esegua un ciclo. Questa guida di ingegneria segue la catena del segnale dal rilevamento e dal condizionamento fino alla trasmissione, all’azione di...

Modbus sulle reti di impianto: frame, registri e limiti di progettazione

Modbus è ancora ampiamente utilizzato perché il suo modello dati è semplice, non perché ogni implementazione lo sia. Questa guida spiega i frame, la mappatura dei registri, la temporizzazione, la...

All'interno della CPU del PLC: cicli di scansione, memoria e selezione

Una guida pratica di ingegneria al funzionamento della CPU di un PLC, dai cicli di scansione deterministici e dalle tabelle delle immagini degli I/O fino a memoria, comunicazioni, diagnostica,...

Guida all’aggiornamento del firmware 1756-L73: scelta tra v19 e v21/v31

Sostituire un 1756-L73 non significa automaticamente aggiornare il firmware. Questa guida confronta le versioni 19.013, 21.011 e 31.011, concentrandosi sulla compatibilità dei progetti, sulle...

Implementazione della logica a scala XOR con 3 interruttori e bit interno

Implementa un circuito luminoso XOR con 3 interruttori SPST in LogixPro o RSLogix 500 utilizzando un bit di relè interno. Include tabelle della verità, equazioni booleane e verifica.