BECKHOFF

CX5130-N031 BECKHOFF Intel Atom Embedded PC with Terminated RS485 Interface

SKU CX5130-N031

Disponibile
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: BECKHOFF
  • Product No.: CX5130-N031
  • Origin Germany
  • Product Type: Embedded PC with Intel Atom® processor
  • Payment: T/T, Western Union
  • Weight: 0.5 kg
  • Shipping port: Xiamen
  • Warranty: 12 months

Tags

Quantità

Product Description

Product Overview

The CX5130-N031 (CX5130N031) is a high-performance, fanless Embedded PC designed for DIN rail mounting, powered by a robust Intel Atom® multi-core processor with a 1.75 GHz clock frequency. This specific model features a factory-integrated RS485 interface via a 9-pin D-sub socket, pre-configured as an end point with internal termination ON.

As a middle-tier powerhouse in the CX5100 series, the CX5130-N031 is engineered for B2B industrial automation applications requiring significant computational power, such as multi-axis motion control, complex gateway functions, and high-level communication tasks. By consolidating high-speed EtherCAT I/O control with a hardware-terminated serial port, it provides a specialized solution for connecting legacy serial networks (Modbus RTU, etc.) to modern Industry 4.0 environments.

Technical Configuration (Deep Dive)

The CX5130-N031 is technically optimized for RS485 bus integrity at the physical layer. The termination on configuration means the internal 120-ohm resistor is engaged, effectively suppressing signal reflections. Configured without echo (half-duplex), it is ready for high-speed, 2-wire serial communication.

The device architecture supports the automatic recognition of both E-bus (EtherCAT) and K-bus (Bus Terminals), allowing users to switch between I/O technologies without changing the CPU. With its multi-core Intel Atom® CPU, the CX5130 provides a substantial performance boost over the CX5120 series, enabling more complex TwinCAT 3 PLC tasks and larger process images while maintaining a fanless, maintenance-free design.

Technical Specifications

Attribute Specification Details
Model CX5130-N031
Brand BECKHOFF
Processor Intel Atom® (1.75 GHz, Multi-core)
Interface Type 1 x RS485
Connection Port 9-pin D-sub socket
RS485 Config End point, without echo, Termination ON
Expansion Bus Automatic E-bus / K-bus recognition
Cooling Fanless (Passive Convection)
Operating Temp -25 to +60 Celsius
Storage Temp -40 to +85 Celsius
Dimensions (W x H x D) 142 mm x 100 mm x 92 mm
Weight Approx. 960 g
Protection Rating IP20
Power Supply 24 VDC (-15 % / +20 %)

Technical FAQs

When should I choose the CX5130-N031 over a non-terminated model?

The CX5130-N031 is designed for use at the physical end of an RS485 daisy chain. If your controller is the final node in a serial network, the internal 120-ohm termination is required to prevent data corruption. If the controller is in the middle of a bus, you should use a model with termination OFF.

What TwinCAT 3 platform level does this unit support?

The CX5130 typically operates at the Performance (40) platform level. This provides sufficient power for demanding PLC, HMI, and basic Motion Control applications within the TwinCAT 3 environment.

Is the RS485 port suitable for Modbus RTU?

Yes. The RS485 interface is a standard physical layer for Modbus RTU. Using the TwinCAT PLC Serial Communication library, the CX5130-N031 can act as a Modbus Master or Slave to communicate with drives, power meters, or third-party controllers.


Engineering & Installation Guide

  • Network Topology Placement: Ensure this unit is positioned at either the start or the end of the RS485 run. Incorrect placement of a terminated node in the middle of a segment will cause impedance mismatch and communication errors.

  • Thermal Clearances: For optimal fanless cooling, the unit must be mounted horizontally on the DIN rail. Maintain at least 30 mm of clearance above and below the cooling fins to allow for natural convection, especially when the ambient temperature approaches 60 Celsius.

  • Bus Integration: The CX5130-N031 automatically detects the I/O bus type. When expanding the system, ensure the total current consumption from the E-bus/K-bus does not exceed the controller's supply limit (typically 2 A). If exceeded, a power feed terminal (EL9410 or similar) must be added.

Engineering Advantages

The CX5130-N031 offers a superior performance-to-size ratio. Its 1.75 GHz multi-core processor allows it to handle significantly higher data throughput and faster cycle times than entry-level embedded PCs. Built with high vibration and shock resistance (conforming to EN 60068-2-6/27), it is designed for continuous operation in the most demanding B2B industrial environments. The combination of pre-configured RS485 termination and automatic bus detection reduces commissioning complexity, making it a highly reliable and flexible solution for modern machine control and industrial networking.

 

Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews

CX5130-N031

Stock & lead time on request

Call
1 su 1

CX5130-N031 BECKHOFF Intel Atom Embedded PC with Terminated RS485 Interface

Only 10 item(s) left in stock
  • Manufacturer: BECKHOFF

  • Product No.: CX5130-N031

  • Country of origin:Germany

  • Product Type: Embedded PC with Intel Atom® processor

  • Payment: T/T, Western Union

  • Weight: 500g

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantità
Visualizza dettagli completi

Product Description

Product Overview

The CX5130-N031 (CX5130N031) is a high-performance, fanless Embedded PC designed for DIN rail mounting, powered by a robust Intel Atom® multi-core processor with a 1.75 GHz clock frequency. This specific model features a factory-integrated RS485 interface via a 9-pin D-sub socket, pre-configured as an end point with internal termination ON.

As a middle-tier powerhouse in the CX5100 series, the CX5130-N031 is engineered for B2B industrial automation applications requiring significant computational power, such as multi-axis motion control, complex gateway functions, and high-level communication tasks. By consolidating high-speed EtherCAT I/O control with a hardware-terminated serial port, it provides a specialized solution for connecting legacy serial networks (Modbus RTU, etc.) to modern Industry 4.0 environments.

Technical Configuration (Deep Dive)

The CX5130-N031 is technically optimized for RS485 bus integrity at the physical layer. The termination on configuration means the internal 120-ohm resistor is engaged, effectively suppressing signal reflections. Configured without echo (half-duplex), it is ready for high-speed, 2-wire serial communication.

The device architecture supports the automatic recognition of both E-bus (EtherCAT) and K-bus (Bus Terminals), allowing users to switch between I/O technologies without changing the CPU. With its multi-core Intel Atom® CPU, the CX5130 provides a substantial performance boost over the CX5120 series, enabling more complex TwinCAT 3 PLC tasks and larger process images while maintaining a fanless, maintenance-free design.

Technical Specifications

Attribute Specification Details
Model CX5130-N031
Brand BECKHOFF
Processor Intel Atom® (1.75 GHz, Multi-core)
Interface Type 1 x RS485
Connection Port 9-pin D-sub socket
RS485 Config End point, without echo, Termination ON
Expansion Bus Automatic E-bus / K-bus recognition
Cooling Fanless (Passive Convection)
Operating Temp -25 to +60 Celsius
Storage Temp -40 to +85 Celsius
Dimensions (W x H x D) 142 mm x 100 mm x 92 mm
Weight Approx. 960 g
Protection Rating IP20
Power Supply 24 VDC (-15 % / +20 %)

Technical FAQs

When should I choose the CX5130-N031 over a non-terminated model?

The CX5130-N031 is designed for use at the physical end of an RS485 daisy chain. If your controller is the final node in a serial network, the internal 120-ohm termination is required to prevent data corruption. If the controller is in the middle of a bus, you should use a model with termination OFF.

What TwinCAT 3 platform level does this unit support?

The CX5130 typically operates at the Performance (40) platform level. This provides sufficient power for demanding PLC, HMI, and basic Motion Control applications within the TwinCAT 3 environment.

Is the RS485 port suitable for Modbus RTU?

Yes. The RS485 interface is a standard physical layer for Modbus RTU. Using the TwinCAT PLC Serial Communication library, the CX5130-N031 can act as a Modbus Master or Slave to communicate with drives, power meters, or third-party controllers.


Engineering & Installation Guide

  • Network Topology Placement: Ensure this unit is positioned at either the start or the end of the RS485 run. Incorrect placement of a terminated node in the middle of a segment will cause impedance mismatch and communication errors.

  • Thermal Clearances: For optimal fanless cooling, the unit must be mounted horizontally on the DIN rail. Maintain at least 30 mm of clearance above and below the cooling fins to allow for natural convection, especially when the ambient temperature approaches 60 Celsius.

  • Bus Integration: The CX5130-N031 automatically detects the I/O bus type. When expanding the system, ensure the total current consumption from the E-bus/K-bus does not exceed the controller's supply limit (typically 2 A). If exceeded, a power feed terminal (EL9410 or similar) must be added.

Engineering Advantages

The CX5130-N031 offers a superior performance-to-size ratio. Its 1.75 GHz multi-core processor allows it to handle significantly higher data throughput and faster cycle times than entry-level embedded PCs. Built with high vibration and shock resistance (conforming to EN 60068-2-6/27), it is designed for continuous operation in the most demanding B2B industrial environments. The combination of pre-configured RS485 termination and automatic bus detection reduces commissioning complexity, making it a highly reliable and flexible solution for modern machine control and industrial networking.

 

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Silver
Country of origin
Germany

Technical knowledge

1756-L73 Firmware Upgrade Guide: v19 vs v21/v31 Decision

Replacing a 1756-L73 does not automatically mean upgrading its firmware. This guide compares v19.013, v21.011 and v31.011, focusing on project compatibility, HMI communications, legacy networks and...

Implementing 3-Switch XOR Ladder Logic with Internal Bit

Implement a 3-SPST switch XOR light circuit in LogixPro or RSLogix 500 using an internal relay bit. Includes truth tables, boolean equations, and verified.

Building a Modbus RTU Network with CompactLogix and DeltaV

Integrate Allen-Bradley CompactLogix, Caterpillar ATS, and generators into DeltaV DCS over Modbus RTU. Covers ProSoft MVI69-MCM, Miille DIN266 gateways.

ONS Instruction Not Energizing OTE in Studio 5000 Ladder Logic

ONS instruction fires but the OTE coil never latches in Studio 5000 because the one-shot is only true for one scan. Use OTL/OTU or seal-in logic instead.

Kinetix 5500 EtherNet/IP Network Switch Requirements and Topology

Configure Allen-Bradley Kinetix 5500 servo drives on EtherNet/IP. Covers CIP Sync, IEEE 1588 V2 timing, Stratix selection, DLR topology, and HMI.

Moving Average Filtering in DCS and PLC Analog Control

A moving-average filter is the sliding-window smoother most instrument engineers drop into DCS and PLC analog paths. Here is how the window works, how N and sample time set lag, and when a...