Delta Electronics

DELTA DVP60ES200RE | DVP-ES2 Series Standard PLC with Ethernet

SKU DVP60ES200RE

Disponibile
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Delta Electronics
  • Product No.: DVP60ES200RE
  • Origin United States
  • Product Type: DVP-ES2 Series Standard PLC with Ethernet Communication
  • Payment: T/T, Western Union
  • Weight: 3.0 kg
  • Shipping port: Xiamen
  • Warranty: 12 months

Tags

Quantità

Product Description

Product Overview

The DVP60ES200RE (DVP60ES200RE) represents the pinnacle of Delta's DVP-ES2 Series, engineered for high-performance sequential control in demanding industrial environments. This modular PLC integrates 36 digital inputs and 24 digital outputs (totaling 60 I/O points), providing a robust control backbone for large-scale automation projects. Specifically designed for high-speed data exchange via its built-in Ethernet communication port, it is a critical component in smart manufacturing, water treatment facilities, and automated packaging lines. By facilitating seamless integration into Industrial Internet of Things (IIoT) architectures, the DVP60ES200RE minimizes system latency and ensures maximum uptime for mission-critical operations.

Technical Configuration

The DVP60ES200RE is built on the advanced ES2 logic platform, optimized for both discrete and process control. The "E" suffix designates its enhanced Ethernet capabilities, supporting Modbus TCP and EtherNet/IP protocols for real-time monitoring and remote diagnostics.

  • Processing Power: High-speed execution of basic instructions at 0.35 microseconds.

  • I/O Density: Features a high-density 60-point configuration, reducing the need for multiple expansion modules and saving valuable DIN-rail space.

  • Communication Interface: Integrated RJ-45 Ethernet port alongside RS-232 and RS-485 ports, allowing simultaneous connection to HMI, SCADA, and downstream frequency drives.

  • Output Reliability: Utilizes robust relay outputs capable of handling diverse load types, offering superior isolation and higher current capacity compared to transistor outputs.

Technical Specifications

Feature Specification
Model DVP60ES200RE
Brand DELTA
Series DVP-ES2
Power Supply 100 to 240 VAC (50/60 Hz)
Input Type 36 Digital Inputs (DC Sink/Source)
Output Type 24 Relay Outputs
Execution Speed 0.35 microseconds (Basic Instruction)
Communication Ethernet, RS-232, RS-485
Operating Temp 0 to 55 deg C
Storage Temp -25 to 70 deg C
Weight 3.0 kg
Origin China / Taiwan

Technical FAQs

How many expansion modules can be connected to the DVP60ES200RE?

The DVP-ES2 series supports up to 8 special expansion modules (including Analog I/O, temperature measurement, and motion control) and a maximum of 256 total I/O points, ensuring scalability for future system upgrades.

What is the primary benefit of the Relay output in this model?

The relay output provides dry contact switching, which allows the PLC to control different voltage levels (both AC and DC) and offers higher resistance to electrical noise and voltage surges compared to solid-state outputs.

Does this PLC support remote programming via Ethernet?

Yes, the built-in Ethernet port allows for remote program upload/download, online monitoring, and firmware updates through Delta's WPLSoft or ISPSoft software suites across a local network or VPN.

What should be checked if the 'ERROR' LED is flashing?

A flashing ERROR LED typically indicates a program syntax error, an I/O configuration mismatch, or a hardware watchdog timer timeout. Check the error code via the peripheral communication port using Delta's diagnostic software.


Engineering & Installation Guide

  • Ethernet Shielding and Routing: For stable communication in high-EMI environments (near VFDs or large motors), utilize shielded Cat5e or Cat6 cables. Ensure the shield is grounded at the switch end to prevent ground loops that can corrupt data packets.

  • Thermal Management: To ensure a long service life, maintain a minimum clearance of 50 mm above and below the unit for natural convection. If the ambient temperature inside the enclosure exceeds 50 deg C, forced air cooling is mandatory.

  • Relay Protection: When switching inductive loads (such as solenoid valves or contactors), always install a snubber circuit (RC for AC loads, flyback diode for DC loads) across the load to prevent back-EMF from prematurely wearing out the internal relay contacts.

 

Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews

DVP60ES200RE

Stock & lead time on request

Call
1 su 1

DELTA DVP60ES200RE | DVP-ES2 Series Standard PLC with Ethernet

Only 10 item(s) left in stock
  • Manufacturer: Delta Electronics

  • Product No.: DVP60ES200RE

  • Country of origin:United States

  • Product Type: DVP-ES2 Series Standard PLC with Ethernet Communication

  • Payment: T/T, Western Union

  • Weight: 3000g

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantità
Visualizza dettagli completi

Product Description

Product Overview

The DVP60ES200RE (DVP60ES200RE) represents the pinnacle of Delta's DVP-ES2 Series, engineered for high-performance sequential control in demanding industrial environments. This modular PLC integrates 36 digital inputs and 24 digital outputs (totaling 60 I/O points), providing a robust control backbone for large-scale automation projects. Specifically designed for high-speed data exchange via its built-in Ethernet communication port, it is a critical component in smart manufacturing, water treatment facilities, and automated packaging lines. By facilitating seamless integration into Industrial Internet of Things (IIoT) architectures, the DVP60ES200RE minimizes system latency and ensures maximum uptime for mission-critical operations.

Technical Configuration

The DVP60ES200RE is built on the advanced ES2 logic platform, optimized for both discrete and process control. The "E" suffix designates its enhanced Ethernet capabilities, supporting Modbus TCP and EtherNet/IP protocols for real-time monitoring and remote diagnostics.

  • Processing Power: High-speed execution of basic instructions at 0.35 microseconds.

  • I/O Density: Features a high-density 60-point configuration, reducing the need for multiple expansion modules and saving valuable DIN-rail space.

  • Communication Interface: Integrated RJ-45 Ethernet port alongside RS-232 and RS-485 ports, allowing simultaneous connection to HMI, SCADA, and downstream frequency drives.

  • Output Reliability: Utilizes robust relay outputs capable of handling diverse load types, offering superior isolation and higher current capacity compared to transistor outputs.

Technical Specifications

Feature Specification
Model DVP60ES200RE
Brand DELTA
Series DVP-ES2
Power Supply 100 to 240 VAC (50/60 Hz)
Input Type 36 Digital Inputs (DC Sink/Source)
Output Type 24 Relay Outputs
Execution Speed 0.35 microseconds (Basic Instruction)
Communication Ethernet, RS-232, RS-485
Operating Temp 0 to 55 deg C
Storage Temp -25 to 70 deg C
Weight 3.0 kg
Origin China / Taiwan

Technical FAQs

How many expansion modules can be connected to the DVP60ES200RE?

The DVP-ES2 series supports up to 8 special expansion modules (including Analog I/O, temperature measurement, and motion control) and a maximum of 256 total I/O points, ensuring scalability for future system upgrades.

What is the primary benefit of the Relay output in this model?

The relay output provides dry contact switching, which allows the PLC to control different voltage levels (both AC and DC) and offers higher resistance to electrical noise and voltage surges compared to solid-state outputs.

Does this PLC support remote programming via Ethernet?

Yes, the built-in Ethernet port allows for remote program upload/download, online monitoring, and firmware updates through Delta's WPLSoft or ISPSoft software suites across a local network or VPN.

What should be checked if the 'ERROR' LED is flashing?

A flashing ERROR LED typically indicates a program syntax error, an I/O configuration mismatch, or a hardware watchdog timer timeout. Check the error code via the peripheral communication port using Delta's diagnostic software.


Engineering & Installation Guide

  • Ethernet Shielding and Routing: For stable communication in high-EMI environments (near VFDs or large motors), utilize shielded Cat5e or Cat6 cables. Ensure the shield is grounded at the switch end to prevent ground loops that can corrupt data packets.

  • Thermal Management: To ensure a long service life, maintain a minimum clearance of 50 mm above and below the unit for natural convection. If the ambient temperature inside the enclosure exceeds 50 deg C, forced air cooling is mandatory.

  • Relay Protection: When switching inductive loads (such as solenoid valves or contactors), always install a snubber circuit (RC for AC loads, flyback diode for DC loads) across the load to prevent back-EMF from prematurely wearing out the internal relay contacts.

 

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Black
Country of origin
United States
Power source
AC-powered

Technical knowledge

Tutto sui PLC: la CPU

A practical engineering guide to PLC CPU operation, from deterministic scan cycles and I/O image tables to memory, communications, diagnostics, redundancy, processor sizing, and reliable system...

Guida all’aggiornamento del firmware 1756-L73: scelta tra v19 e v21/v31

Sostituire un 1756-L73 non significa automaticamente aggiornare il firmware. Questa guida confronta le versioni 19.013, 21.011 e 31.011, concentrandosi sulla compatibilità dei progetti, sulle...

Implementazione della logica a scala XOR con 3 interruttori e bit interno

Implementa un circuito luminoso XOR con 3 interruttori SPST in LogixPro o RSLogix 500 utilizzando un bit di relè interno. Include tabelle della verità, equazioni booleane e verifica.

Creazione di una rete Modbus RTU con CompactLogix e DeltaV

Integra Allen-Bradley CompactLogix, Caterpillar ATS e generatori nel DCS DeltaV tramite Modbus RTU. Include i gateway ProSoft MVI69-MCM e Miille DIN266.

Istruzione ONS che non attiva l’OTE nella logica ladder di Studio 5000

L’istruzione ONS si attiva, ma la bobina OTE non rimane mai eccitata in Studio 5000 perché il one-shot è vero solo per una scansione. Usa OTL/OTU oppure una logica di autoritenuta.

Requisiti e topologia dello switch di rete EtherNet/IP Kinetix 5500

Configura i servoazionamenti Allen-Bradley Kinetix 5500 su EtherNet/IP. Include CIP Sync, la temporizzazione IEEE 1588 V2, la selezione degli switch Stratix, la topologia DLR e l’HMI.