Honeywell

Honeywell CC-TFB412 51308311-275 Experion Series C Fieldbus Interface IOTA Module

SKU CC-TFB412 51308311-275

Disponibile
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Honeywell
  • Product No.: CC-TFB412 51308311-275
  • Origin United States
  • Product Type: Fieldbus Interface IOTA Module
  • Barcode: 8537101190
  • Payment: T/T, Western Union
  • Weight: 0.45 kg
  • Dimensions: 130 mm x 130 mm x 85 mm (H x W x D)
  • Shipping port: Xiamen
  • Warranty: 12 months

Tags

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

Honeywell CC-TFB412 51308311-275 Experion Series C Fieldbus Interface IOTA Module

Quantità

Product Description

Description

The Honeywell CC-TFB412 (Part Number:51308311-275 ) is a redundant Fieldbus Interface Input Output Termination Assembly (IOTA) module designed for the Experion Series C system. It provides physical termination and connection points for field-level network gateways and I/O modules when used in conjunction with the C300 Controller. The CC-TFB412 features a chassis-less mounting design, allowing electronic modules to plug directly onto the termination assembly to combine electronics and field wiring in a single area. The module is conformally coated for enhanced environmental protection.

Features

  • Support for redundant Fieldbus interface configurations
  • Chassis-less mounting structure for direct module integration
  • Conformally coated printed wiring boards for environmental protection
  • Integrated Ethernet interface connections

Applications

  • Distributed process control systems
  • Industrial automation fieldbus communication networks
  • Experion Series C and C300 Controller system deployments

Technical Specifications

Parameter Specification
Manufacturer Honeywell
Model CC-TFB412
Part Number 51308311-275
Voltage 12 VDC
Current 100 mA
Load Voltage 24 VDC
Load Current 0.196 A
Operating Temperature -40 to 185 degF (-40 to 85 degC)
Storage Temperature -40 to 185 degF (-40 to 85 degC)
Redundancy Redundant
Ethernet Connections 4 RJ-45 Connections
FF Wiring 24 VDC (external) / 350 mA total

Installation Guidelines

  • Mount the module to compatible Experion Series C termination assembly locations.
  • Ensure proper field wiring connection for 24 VDC external power and fieldbus communication links.
  • Route Ethernet lines via the dedicated RJ-45 redundant network connectors.
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
FAQ
What is the Honeywell CC-TFB412 used for?
The Honeywell CC-TFB412 is a redundant Fieldbus Interface Input Output Termination Assembly (IOTA) module used in the Experion Series C system to provide termination and connection points for fieldbus networks and C300 Controllers.
Which system does the CC-TFB412 module belong to?
The module belongs to the Honeywell Experion Series C process control system and operates alongside C300 Controllers.
Does the CC-TFB412 support redundant communication connections?
Yes. The module supports redundant Fieldbus interface configurations and includes 4 RJ-45 Ethernet connections for network routing.
What power parameters are specified for the Honeywell CC-TFB412?
The module operates at 12 VDC at 100 mA, with load specifications of 24 VDC and 0.196 A, plus support for external 24 VDC FF wiring at 350 mA total.
Reviews

CC-TFB412 51308311-275

Stock & lead time on request

Call
1 su 3

Honeywell CC-TFB412 51308311-275 Experion Series C Fieldbus Interface IOTA Module

Only 3 item(s) left in stock
  • Manufacturer: Honeywell

  • Product No.: CC-TFB412 51308311-275

  • Country of origin:United States

  • Product Type: Fieldbus Interface IOTA Module

  • Barcode: 8537101190

  • Payment: T/T, Western Union

  • Weight: 450g

  • Dimensions: 130 mm x 130 mm x 85 mm (H x W x D)

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantità
Visualizza dettagli completi

Product Description

Description

The Honeywell CC-TFB412 (Part Number:51308311-275 ) is a redundant Fieldbus Interface Input Output Termination Assembly (IOTA) module designed for the Experion Series C system. It provides physical termination and connection points for field-level network gateways and I/O modules when used in conjunction with the C300 Controller. The CC-TFB412 features a chassis-less mounting design, allowing electronic modules to plug directly onto the termination assembly to combine electronics and field wiring in a single area. The module is conformally coated for enhanced environmental protection.

Features

  • Support for redundant Fieldbus interface configurations
  • Chassis-less mounting structure for direct module integration
  • Conformally coated printed wiring boards for environmental protection
  • Integrated Ethernet interface connections

Applications

  • Distributed process control systems
  • Industrial automation fieldbus communication networks
  • Experion Series C and C300 Controller system deployments

Technical Specifications

Parameter Specification
Manufacturer Honeywell
Model CC-TFB412
Part Number 51308311-275
Voltage 12 VDC
Current 100 mA
Load Voltage 24 VDC
Load Current 0.196 A
Operating Temperature -40 to 185 degF (-40 to 85 degC)
Storage Temperature -40 to 185 degF (-40 to 85 degC)
Redundancy Redundant
Ethernet Connections 4 RJ-45 Connections
FF Wiring 24 VDC (external) / 350 mA total

Installation Guidelines

  • Mount the module to compatible Experion Series C termination assembly locations.
  • Ensure proper field wiring connection for 24 VDC external power and fieldbus communication links.
  • Route Ethernet lines via the dedicated RJ-45 redundant network connectors.

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

Honeywell CC-TFB412 51308311-275 Experion Series C Fieldbus Interface IOTA Module

What is the Honeywell CC-TFB412 used for?

The Honeywell CC-TFB412 is a redundant Fieldbus Interface Input Output Termination Assembly (IOTA) module used in the Experion Series C system to provide termination and connection points for fieldbus networks and C300 Controllers.

Which system does the CC-TFB412 module belong to?

The module belongs to the Honeywell Experion Series C process control system and operates alongside C300 Controllers.

Does the CC-TFB412 support redundant communication connections?

Yes. The module supports redundant Fieldbus interface configurations and includes 4 RJ-45 Ethernet connections for network routing.

What power parameters are specified for the Honeywell CC-TFB412?

The module operates at 12 VDC at 100 mA, with load specifications of 24 VDC and 0.196 A, plus support for external 24 VDC FF wiring at 350 mA total.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Silver
Country of origin
United States
Power source
DC Power

Technical knowledge

Tutto sui PLC: la CPU

A practical engineering guide to PLC CPU operation, from deterministic scan cycles and I/O image tables to memory, communications, diagnostics, redundancy, processor sizing, and reliable system...

1756-L73 Firmware Upgrade Guide: v19 vs v21/v31 Decision

Replacing a 1756-L73 does not automatically mean upgrading its firmware. This guide compares v19.013, v21.011 and v31.011, focusing on project compatibility, HMI communications, legacy networks and...

Implementazione della logica a scala XOR con 3 interruttori e bit interno

Implementa un circuito luminoso XOR con 3 interruttori SPST in LogixPro o RSLogix 500 utilizzando un bit di relè interno. Include tabelle della verità, equazioni booleane e verifica.

Creazione di una rete Modbus RTU con CompactLogix e DeltaV

Integra Allen-Bradley CompactLogix, Caterpillar ATS e generatori nel DCS DeltaV tramite Modbus RTU. Include i gateway ProSoft MVI69-MCM e Miille DIN266.

Istruzione ONS che non attiva l’OTE nella logica ladder di Studio 5000

L’istruzione ONS si attiva, ma la bobina OTE non rimane mai eccitata in Studio 5000 perché il one-shot è vero solo per una scansione. Usa OTL/OTU oppure una logica di autoritenuta.

Requisiti e topologia dello switch di rete EtherNet/IP Kinetix 5500

Configura i servoazionamenti Allen-Bradley Kinetix 5500 su EtherNet/IP. Include CIP Sync, la temporizzazione IEEE 1588 V2, la selezione degli switch Stratix, la topologia DLR e l’HMI.