Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

Triconex 4200 / REM 4200 Primary Remote Extender Module

Quantità

Product Description

The Triconex 4200 is a primary remote extender module designed for extending the I/O bus interface between the main chassis and remote expansion chassis in Tricon v10 safety-critical systems. The module operates using multi-mode fiber optic links running at a communication rate of 375 Kbaud to provide galvanic and ground loop isolation between system chassis. Interfacing via unidirectional transmit and receive cabling ports, the 4200 maintains triple modular redundant (TMR) system architecture while serving as a Class 1E to non-1E isolator between safety-related main chassis and non-safety expansion units.

Features

  • Fiber optic multi-mode interface for remote chassis I/O expansion
  • Ground loop isolation between primary and remote chassis
  • Unidirectional transmit and receive cabling ports
  • High immunity against electrostatic and electromagnetic interference
  • Supports Class 1E to non-1E isolation applications

Applications

  • Nuclear power plant safety-related control and protection systems
  • High-availability emergency shutdown (ESD) systems
  • Remote I/O chassis extension across long physical distances

Technical Specifications

Parameter Specification
Manufacturer Triconex / Invensys
Model 4200 / REM4200 / REM 4200
Module Type Primary Remote Extender Module (RXM)
Cable Type Multi-mode Fiber Optic
Communication Rate 375 Kbaud
Primary System Compatibility Tricon v10 Main Chassis (Model 8110)
Remote Module Compatibility Triconex 4201 Remote Extender Module

Installation Guidelines

  • Fiber Optic Cabling: Connect two fiber optic cables between each primary RXM (4200) and remote RXM (4201) pair; one cable dedicated to transmitting data from the primary to the remote module, and the second cable dedicated to receiving data from the remote module.
  • Chassis Arrangement: Ensure three identical RXM modules are installed per chassis set to support the triplicated I/O bus structure.
  • Isolation Applications: Utilize fiber optic connections to maintain physical and electrical isolation when linking Class 1E safety-related chassis to non-1E expansion chassis.

Compliance and Certifications

  • EPRI TR-107330
  • IEEE Std 323
  • IEEE Std 384
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
FAQ
What cable type is required to connect the primary remote extender module?
The module requires multi-mode fiber optic cables with separate unidirectional lines for data transmit and receive functions.
What communication baud rate does the fiber optic link support?
The multi-mode fiber optic link operates at a fixed communication rate of 375 Kbaud.
Can the module isolate Class 1E safety equipment from non-1E equipment?
The fiber optic connection inherently provides ground loop isolation to function as a Class 1E to non-1E isolator.
Reviews

4200

Stock & lead time on request

Call
1 su 1

Triconex 4200 / REM 4200 Primary Remote Extender Module

Only 5 item(s) left in stock
  • Manufacturer: Triconex

  • Product No.: 4200

  • Country of origin:United States

  • Product Type: Remote Extender Module

  • Payment: T/T, Western Union

  • Weight: 1100g

  • Dimensions: 30.5 cm x 7.6 cm x 26.7 cm

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantità
Visualizza dettagli completi

Product Description

The Triconex 4200 is a primary remote extender module designed for extending the I/O bus interface between the main chassis and remote expansion chassis in Tricon v10 safety-critical systems. The module operates using multi-mode fiber optic links running at a communication rate of 375 Kbaud to provide galvanic and ground loop isolation between system chassis. Interfacing via unidirectional transmit and receive cabling ports, the 4200 maintains triple modular redundant (TMR) system architecture while serving as a Class 1E to non-1E isolator between safety-related main chassis and non-safety expansion units.

Features

  • Fiber optic multi-mode interface for remote chassis I/O expansion
  • Ground loop isolation between primary and remote chassis
  • Unidirectional transmit and receive cabling ports
  • High immunity against electrostatic and electromagnetic interference
  • Supports Class 1E to non-1E isolation applications

Applications

  • Nuclear power plant safety-related control and protection systems
  • High-availability emergency shutdown (ESD) systems
  • Remote I/O chassis extension across long physical distances

Technical Specifications

Parameter Specification
Manufacturer Triconex / Invensys
Model 4200 / REM4200 / REM 4200
Module Type Primary Remote Extender Module (RXM)
Cable Type Multi-mode Fiber Optic
Communication Rate 375 Kbaud
Primary System Compatibility Tricon v10 Main Chassis (Model 8110)
Remote Module Compatibility Triconex 4201 Remote Extender Module

Installation Guidelines

  • Fiber Optic Cabling: Connect two fiber optic cables between each primary RXM (4200) and remote RXM (4201) pair; one cable dedicated to transmitting data from the primary to the remote module, and the second cable dedicated to receiving data from the remote module.
  • Chassis Arrangement: Ensure three identical RXM modules are installed per chassis set to support the triplicated I/O bus structure.
  • Isolation Applications: Utilize fiber optic connections to maintain physical and electrical isolation when linking Class 1E safety-related chassis to non-1E expansion chassis.

Compliance and Certifications

  • EPRI TR-107330
  • IEEE Std 323
  • IEEE Std 384

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

Triconex 4200 / REM 4200 Primary Remote Extender Module

What cable type is required to connect the primary remote extender module?

The module requires multi-mode fiber optic cables with separate unidirectional lines for data transmit and receive functions.

What communication baud rate does the fiber optic link support?

The multi-mode fiber optic link operates at a fixed communication rate of 375 Kbaud.

Can the module isolate Class 1E safety equipment from non-1E equipment?

The fiber optic connection inherently provides ground loop isolation to function as a Class 1E to non-1E isolator.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
United States

Technical knowledge

Tutto sui PLC: la CPU

A practical engineering guide to PLC CPU operation, from deterministic scan cycles and I/O image tables to memory, communications, diagnostics, redundancy, processor sizing, and reliable system...

Guida all’aggiornamento del firmware 1756-L73: scelta tra v19 e v21/v31

Sostituire un 1756-L73 non significa automaticamente aggiornare il firmware. Questa guida confronta le versioni 19.013, 21.011 e 31.011, concentrandosi sulla compatibilità dei progetti, sulle...

Implementazione della logica a scala XOR con 3 interruttori e bit interno

Implementa un circuito luminoso XOR con 3 interruttori SPST in LogixPro o RSLogix 500 utilizzando un bit di relè interno. Include tabelle della verità, equazioni booleane e verifica.

Creazione di una rete Modbus RTU con CompactLogix e DeltaV

Integra Allen-Bradley CompactLogix, Caterpillar ATS e generatori nel DCS DeltaV tramite Modbus RTU. Include i gateway ProSoft MVI69-MCM e Miille DIN266.

Istruzione ONS che non attiva l’OTE nella logica ladder di Studio 5000

L’istruzione ONS si attiva, ma la bobina OTE non rimane mai eccitata in Studio 5000 perché il one-shot è vero solo per una scansione. Usa OTL/OTU oppure una logica di autoritenuta.

Requisiti e topologia dello switch di rete EtherNet/IP Kinetix 5500

Configura i servoazionamenti Allen-Bradley Kinetix 5500 su EtherNet/IP. Include CIP Sync, la temporizzazione IEEE 1588 V2, la selezione degli switch Stratix, la topologia DLR e l’HMI.