B&R X20AO4632 X20 Analog Output Module

B&R X20AO4632 X20 Analog Output Module

Only 10 item(s) left in stock
  • Manufacturer: B&R

  • Product No.: X20AO4632

  • Country of origin:United States

  • Product Type: Analog Outputs

  • Payment: T/T, Western Union

  • Weight: 1000g

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantity
View full details

Process Control Overview

The B&R X20AO4632 (X20AO4632) is a high-density 4-channel analog output module engineered for the modular B&R X20 automation architecture. Deployed extensively across precision process industries such as chemical dosing, paper manufacturing, and variable speed ventilation systems, this module drives proportional field actuators. By converting internal digital control variables into stable, low-noise analog signals, the unit ensures responsive control over control valves, motorized dampers, and variable frequency drive (VFD) speed references, minimizing process overshoot and maximizing factory output quality.

Signaling Architecture and Electrical Precision

This analog card features four independently configurable outputs that provide standard 0 to 10 VDC voltage signals or 4 to 20 mA current loops based on software parameters in B&R Automation Studio. Operating with high digital resolution, the module uses specialized internal balancing circuits to maintain signal stability despite fluctuations in backplane voltage or shifting ambient temperatures. The hardware includes comprehensive galvanic isolation between the internal logic bus and the field output channels, protecting sensitive CPU components from external inductive surges and common-mode voltage spikes.

Technical Performance Matrix

Core Parameter Functional Specification
Model X20AO4632
Brand B&R Automation
Origin Austria
Module Classification Analog Signal Output Card
Channel Density 4 analog outputs
Signal Ranges 0 to 10 VDC or 4 to 20 mA (Software selectable)
Galvanic Isolation Field channels isolated from the X20 backplane
Output Data Representation 16-bit standard Integer (INT)
Operating Temperature 0 to 55 deg C (Standard horizontal mounting)
Storage Temperature -25 to 85 deg C
Relative Humidity Range 5 to 95% (Non-condensing)
Net Weight 0.09 kg
Shipping Gross Weight 1.0 kg (Including rigid anti-static packaging)

Industrial Maintenance and FAQs

How do you configure a channel to switch from a 0-10 V voltage signal to a 4-20 mA current signal?

Physical jumpers are not required. Open the physical hardware topology configuration tree inside B&R Automation Studio, select the specific slot containing the X20AO4632 module, and navigate to its channel parameter tab. Modify the channel mode dropdown to the desired signaling standard and download the updated configuration to the target controller.

What are the primary troubleshooting steps if an actuator fails to respond to a current loop command?

First, check the physical diagnostics LED on the front faceplate of the module. If a current loop channel detects an open circuit (broken wire or disconnected actuator terminal), a fault indicator will activate. Verify line continuity using a digital multimeter, check the external loop resistance to ensure it falls within permissible limits, and verify that the auxiliary 24 VDC potential feed module is active.

Can this module output negative voltage signals for bidirectional servo drive control?

No. The X20AO4632 is calibrated specifically for unipolar industrial signaling standards, providing 0 to 10 VDC or 4 to 20 mA. For application loops requiring bipolar voltage ranges (such as -10 V to +10 V) for hydraulic valves or bidirectional servo controllers, utilize a dedicated B&R bipolar analog output module.


Field Commissioning and Wiring Guidelines

  • Shield Termination and Noise Suppression: Always utilize high-quality shielded twisted-pair cables for all analog signal runs. Terminate the cable braid directly at the module base using the official X20 low-impedance ground clip assembly. Grounding the shield correctly prevents electromagnetic interference from high-voltage AC motor lines from corrupting the precise voltage or current waveforms.

  • Loop Impedance Tracking: When operating in 4 to 20 mA current mode, calculate the total loop resistance, including the internal resistance of the actuator and the total length of the field wire run. Exceeding the maximum permissible load impedance will prevent the module from driving the full 20 mA target signal, resulting in clamped output values and process errors.

  • Module Seating and Terminal Engagement: Prior to sliding the X20AO4632 electronics module onto its pre-installed bus base, ensure that the mechanical coding pins are properly aligned. Press the module firmly into place until the top and bottom latch mechanisms click, establishing a low-resistance connection to the logic bus and avoiding intermittent data transmission faults.

 

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Greyish White
Country of origin
United States
Power source
DC Power

Recently Viewed Products

Technical knowledge

Guide to Robotic Grippers: From Delicate Handling to Heavy-Duty Automation

Modern robotic grippers are evolving beyond traditional mechanical jaws. From gecko-inspired adhesive systems and soft food-grade grippers to AI-powered warehouse tools, advanced gripping...

Throwback: How Early Electric Motors Changed Underground Mining

From rope-driven DC compressors to battery-powered mine carts, early mining operations marked a turning point in industrial electrification. This article explores how electric motors transformed...

Factory I/O: A Modern PLC Simulation Tool for Industrial Automation Training

Factory I/O is transforming PLC education by delivering immersive 3D industrial simulations for students, engineers, and maintenance teams. The platform bridges the gap between theory and real-world...

Programming Single-Axis Motion Cycles on a CMZ Servo Drive

This tutorial examines how onboard PLC functionality inside a CMZ SBD servo drive can execute standalone motion programs, including homing logic, position control, and cyclic axis movement without an...

Single-Axis Motion Control Setup with CMZ Servo Drives

This tutorial explores the commissioning of a single-axis servo motion system using a CMZ SBD drive, covering hardware setup, axis scaling, homing configuration, and safe motion verification for...

Mitsubishi FX PLC Integration With FR-D700 VFD and HMI Control

This tutorial explains how Mitsubishi FX PLCs integrate with FR-D700 VFDs and HMI panels for forward/reverse motor control. It covers wiring logic, parameter configuration, ladder programming, and...