BECKHOFF

Beckhoff CX1500-M200 CX Series Lightbus Master Connection Module

SKU CX1500-M200

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: BECKHOFF

  • Product No.: CX1500-M200

  • Country of origin:Germany

  • Product Type: PLC Communication Modules

  • Payment: T/T, Western Union

  • Weight: 500g

  • Dimensions: 38 mm x 100 mm x 91 mm

  • Shipping port: Xiamen

  • Warranty: 12 months

Description

Designed for seamless integration within modular industrial control environments, the Beckhoff CX1500-M200 fieldbus master connection establishes high-speed Lightbus communications directly from a compatible CX-series CPU. By utilizing fiber optic physical layers, this interface module guarantees complete electrical isolation and exceptional noise immunity across distributed field systems. The integration with the host controller is achieved through a high-bandwidth 2 kbytes DPRAM interface over an ISA plug-and-play architecture, ensuring rapid cyclic data exchanges. Perfect for synchronized motion and distributed I/O systems, the device supports both free-running and synchronized process data communication modes depending on the application requirements.

Features

  • High-Speed Transmission: Supports a fixed 2.5 Mbaud data transfer rate, capable of cycling 32 bits of process data in 25 microseconds.
  • Fiber Optic Physical Layer: Equipped with dual fiber optic interfaces to prevent electromagnetic interference and ground loops.
  • Large Network Capacity: Manages up to 254 distinct nodes with an aggregate capacity of up to 65,280 industrial I/O points.
  • TwinCAT Integration: Direct hardware driver compatibility with the TwinCAT 2 software platform for simplified system configuration.
  • Industrial Durability: Robust IP20 enclosure rated to withstand harsh mechanical vibration and thermal environments.

Applications

  • High-speed multi-axis motion synchronization over fiber optic rings.
  • Industrial manufacturing plants with severe electromagnetic noise and interference.
  • Distributed telemetry systems and high-density I/O networking over extended distances.
  • Legacy machine retrofits and maintenance of TwinCAT 2 control architectures.

Technical Specifications

Parameter Specification Value
Manufacturer Beckhoff
Model / Article Number CX1500-M200
Fieldbus System Lightbus
Data Transfer Rate 2.5 Mbaud
Process Data Cycle Time 32 bits in 25 microseconds
Bus Interface 2 x fiber optic ports
Maximum Nodes 254 nodes (max. 65,280 I/O points)
CPU Interface ISA plug and play, 2 kbytes DPRAM
Max. Power Loss 2 W
Operating Temperature 0 to +55 degC
Storage Temperature -25 to +85 degC
Relative Humidity 95%, non-condensing
Protection Rating IP20
Driver Support Compatible only with TwinCAT 2
Vibration/Shock Resistance Conforms to EN 60068-2-6 / EN 60068-2-27
EMC Immunity/Emission Conforms to EN 61000-6-2 / EN 61000-6-4
Approvals CE, UL
Dimensions (W x H x D) 38 mm x 100 mm x 91 mm
Net Weight 190 g
Shipping Weight (Calculated) 2.0 kg

Connections and Interfaces

Port / Interface Type Function / Assignment
Optical Port 1 (Tx) Lightbus optical transmitter connection to the ring network.
Optical Port 2 (Rx) Lightbus optical receiver connection completing the ring loop.
Backplane Interface Integrated PC104/ISA Bus for physical connection and power distribution from the CX CPU.

Empirical Engineering Insights

Alternative Models & Compatibility

The CX1500-M200 is designed exclusively for CX-series hardware configurations operating under TwinCAT 2 runtimes. It cannot be mapped or configured under TwinCAT 3 due to the hardware-level dependencies of the legacy ISA DPRAM address space. Ensure your system CPU supports PC104 expansion channels before engineering replacements.

Application Pitfalls & Engineering Notes

When laying optical fiber cables for the Lightbus loop, strictly adhere to the manufacturer's specified minimum bending radius. Kinking or over-bending the optical fibers causes critical light signal attenuation, leading to intermittent cyclic redundancy check (CRC) errors or complete bus synchronization failures.

Commissioning & Wiring Tips

Always power down the control stack before cleaning or inserting optical fiber connectors. Dust ingress within the active physical transceivers can permanently degrade light output. Prior to initial startup, verify the mechanical alignment of the CPU extension connector to avoid bent pins on the backplane.

Installation Guidelines

CRITICAL WARNING:

Isolate and lock out all power sources feeding the host controller and connected field devices before initiating module insertion or removal. Failing to perform total system de-energization may damage the sensitive DPRAM physical layer of the host CPU and invalidate your warranty.

1
Power down the main control cabinet and verify that no residual energy remains in any auxiliary supply lines.
2
Mount the module directly onto the standard DIN rail (TS35), sliding it towards the host CX controller stack until the backplane contacts engage firmly.
3
Secure the stack by snapping end brackets on both sides of the assembled system to prevent side-to-side drift or mechanical disconnection.
4
Connect the incoming and outgoing fiber optic cables, confirming that the Tx (transmit) line connects to the corresponding Rx (receive) port of the adjacent field node.

FAQ

Is this Lightbus module compatible with TwinCAT 3?

No, this connection module is strictly compatible with TwinCAT 2 and does not support TwinCAT 3 environments due to legacy driver structures.

What is the maximum node capacity of the system?

The master interface can control up to 254 nodes, supporting a maximum of 65,280 physical I/O points.

What are the interface cycle times for process data?

The module transfers 32 bits of process data in 25 microseconds at a physical baud rate of 2.5 Mbaud.

What type of cabling is required for the bus interface?

It requires standard fiber-optic cables (2x interface ports) supporting the Lightbus ring configuration.

View all FAQs →

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 10 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Technical knowledge

IC693CPU360 vs IC693CPU364: Ethernet and Power Budget

Compare the IC693CPU360 and IC693CPU364 by Ethernet interface, +5 VDC load, memory, rack limits, and replacement checks.

1756-OF4 Output Wrong? Check Mode, RTB, and Scaling First

A field-first diagnostic sequence for 1756-OF4 analog output problems: channel mode, removable terminal block, scaling, and controlled electrical checks.

1746-OA8 vs 1746-OA16: Output Count and Current Limits

A direct comparison of 1746-OA8 and 1746-OA16 output count, common grouping, backplane current and temperature-derated load limits.

Replacing a 1761-NET-DNI: Capture These Settings First

A field checklist for recording the 1761-NET-DNI hardware series, firmware, EDS file, DF1 settings, DeviceNet address and messaging configuration before replacement.

EL3062 vs EL3062-0030: The Input Range Changes

The EL3062 is a 0–10 V EtherCAT terminal. The EL3062-0030 is a 0–30 V variant. This checklist covers identification, scaling and commissioning.

Replacing a 1769-OW8: Checks Before Moving Relay Loads

A field checklist for replacing Allen-Bradley 1769-OW8 relay output modules without losing load-group, wiring, and commissioning details.