Implementing 3-Switch XOR Ladder Logic with Internal Bit
Implement a 3-SPST switch XOR light circuit in LogixPro or RSLogix 500 using an internal relay bit. Includes truth tables, boolean equations, and verified.
The Bently Nevada 177230-02-02-05 is a loop-powered Seismic Transmitter designed for continuous overall machinery vibration monitoring. It integrates a piezoceramic shear sensing element with internal signal conditioning circuitry to process machine surface vibration into two distinct output formats: a primary 4 to 20 mA current loop proportional to velocity vibration and a secondary unbuffered dynamic acceleration voltage signal.
Configured with specific performance parameters, the Bently Nevada 177230-02-02-05 Seismic Transmitter features a full-scale velocity measurement range of 0 to 50.8 mm/s (0 to 2.0 in/s). Its primary current loop operates over a frequency bandpass of 3 Hz to 1 kHz (180 to 60 kcps) peak, providing reliable detection of low-to-mid frequency rotational flaws. The secondary dynamic signal provides raw acceleration data with a sensitivity of 10.2 mV/m/s² (100 mV/g) ±20% across a wider 2.5 Hz to 10 kHz frequency range for detailed diagnostic analysis.
The unit carries the 05 agency approval option, certifying it for deployment in hazardous areas with multiple North American and European approvals, including CSA/cNRTLus Class I Div 1/Div 2 and ATEX/IECEx Zone 0/1/2 ratings. Housed in a hermetically sealed 316L stainless steel enclosure with a top-mounted 3-pin MIL-C-5015 electrical connector, it connects directly to Programmable Logic Controllers (PLCs), Distributed Control Systems (DCS), and Supervisory Control and Data Acquisition (SCADA) platforms.
| Option Code | Description |
|---|---|
| 177230 | Seismic Transmitter Base Model |
| A: Measurement Range | 02 = 0 to 50.8 mm/s (0 to 2.0 in/s) |
| B: Frequency | 02 = 3 Hz to 1 kHz (180 to 60 kcps) pk |
| C: Approvals | 05 = Multiple Approvals (CSA/NRTL/C, ATEX/IECEx) |
| Parameter | Specification |
|---|---|
| Manufacturer | Bently Nevada |
| Part Number | 177230-02-02-05 |
| Product Type | Seismic Transmitter |
| Sensing Element Type | Ceramic / Shear |
| Case Material | 316L stainless steel |
| Electrical Connector | 3-pin MIL-C-5015, 316L stainless steel |
| Weight | 131 g (4.62 oz) typical |
| Height | 66.0 mm (2.60 in) |
| Diameter | 25.4 mm (1.00 in) |
| Shipping Weight | 1.0 kg (Estimated) |
| Parameter | Specification |
|---|---|
| Main Loop Output (Pin A ref Pin B) | 4 to 20 mA current loop, Velocity vibration |
| Excitation Voltage | 12 to 30 Vdc (current limited to 40 mA) |
| Settling Time | Less than 15 seconds within 2% of final value |
| Dynamic Output Sensitivity (Pin C ref Pin B) | 10.2 mV/m/s² (100 mV/g) ±20% |
| Dynamic Output Format | Voltage, Acceleration vibration, unbuffered |
| Dynamic Output Bias Voltage | 2.5 V ±0.1 V |
| Dynamic Full Scale Range | 147 m/s² (15 g's) peak |
| Electrical Isolation | Greater than 10^8 ohms |
| Isolation Breakdown Voltage | 600 Vrms with less than 1 mA leakage current |
| Parameter | Specification |
|---|---|
| Velocity Measurement Range | 0 to 50.8 mm/s (0 to 2.0 in/s) |
| Main Loop Frequency Response | 3 Hz to 1 kHz (180 to 60 kcps) ±10% |
| Main Loop Linearity | ±1% |
| Dynamic Output Frequency Response | 2.5 Hz to 10 kHz (150 cpm to 600 kcps) ±10% |
| Mounted Resonant Frequency | Greater than 12 kHz |
| Transverse Sensitivity | Less than 5% of sensitivity |
| Parameter | Specification |
|---|---|
| Operating Temperature Range | -40 degC to +85 degC (-40 degF to +185 degF) |
| Relative Humidity | To 100% non-submerged |
| Sensor Seal | Hermetically sealed |
| Shock Survivability | 9,810 m/s² (1,000 g peak) maximum drop test |
| Magnetic Field Sensitivity (Velocity) | Less than 20 um/s/gauss (790 uin/s/gauss) peak |
| Magnetic Field Sensitivity (Acceleration) | Less than 14.7 mm/s²/gauss (150 ug/gauss) peak |
| Connector Pin | Signal Description |
|---|---|
| Pin A | 4-20 mA Positive Loop (12 to 30 Vdc Loop Power) |
| Pin B | 4-20 mA Negative Loop / Common return for Dynamic Signal |
| Pin C | Dynamic Signal Output (Unbuffered acceleration voltage, referenced to Pin B) |
Wiring Precaution: The Dynamic Signal Negative (Pin B) requires complete isolation from earth ground. If Pin B is inadvertently grounded, the 4 to 20 mA loop will short-circuit, resulting in zero current output.
| Certification / Standard | Scope & Rating |
|---|---|
| FCC | Complies with Part 15 of FCC Rules |
| EMC | European Directive 2014/30/EU |
| RoHS | European Directive 2011/65/EU |
| Maritime | DNV rules for classification (Ships, High speed & light craft, Offshore standards) |
| cNRTLus |
Ex nL IIC T4; AEx nA IIC T4 (Class I, Div 2, Groups A, B, C, D) Ex ia IIC T4; AEx ia IIC T4 (Class I, Div 1, Groups A, B, C, D; Class II, Div 1, Groups E, F, G; Class III, Div 1) |
| ATEX / IECEx |
II 1G Ex ia IIC T4 Ga (Zone 0/1) II 3G Ex nA IIC T4 Gc (Zone 2) Operating Temperature: Ta = -40 degC to +80 degC |
Global Express Shipping
Returns & Warranty



The Bently Nevada 177230-02-02-05 is a loop-powered Seismic Transmitter designed for continuous overall machinery vibration monitoring. It integrates a piezoceramic shear sensing element with internal signal conditioning circuitry to process machine surface vibration into two distinct output formats: a primary 4 to 20 mA current loop proportional to velocity vibration and a secondary unbuffered dynamic acceleration voltage signal.
Configured with specific performance parameters, the Bently Nevada 177230-02-02-05 Seismic Transmitter features a full-scale velocity measurement range of 0 to 50.8 mm/s (0 to 2.0 in/s). Its primary current loop operates over a frequency bandpass of 3 Hz to 1 kHz (180 to 60 kcps) peak, providing reliable detection of low-to-mid frequency rotational flaws. The secondary dynamic signal provides raw acceleration data with a sensitivity of 10.2 mV/m/s² (100 mV/g) ±20% across a wider 2.5 Hz to 10 kHz frequency range for detailed diagnostic analysis.
The unit carries the 05 agency approval option, certifying it for deployment in hazardous areas with multiple North American and European approvals, including CSA/cNRTLus Class I Div 1/Div 2 and ATEX/IECEx Zone 0/1/2 ratings. Housed in a hermetically sealed 316L stainless steel enclosure with a top-mounted 3-pin MIL-C-5015 electrical connector, it connects directly to Programmable Logic Controllers (PLCs), Distributed Control Systems (DCS), and Supervisory Control and Data Acquisition (SCADA) platforms.
| Option Code | Description |
|---|---|
| 177230 | Seismic Transmitter Base Model |
| A: Measurement Range | 02 = 0 to 50.8 mm/s (0 to 2.0 in/s) |
| B: Frequency | 02 = 3 Hz to 1 kHz (180 to 60 kcps) pk |
| C: Approvals | 05 = Multiple Approvals (CSA/NRTL/C, ATEX/IECEx) |
| Parameter | Specification |
|---|---|
| Manufacturer | Bently Nevada |
| Part Number | 177230-02-02-05 |
| Product Type | Seismic Transmitter |
| Sensing Element Type | Ceramic / Shear |
| Case Material | 316L stainless steel |
| Electrical Connector | 3-pin MIL-C-5015, 316L stainless steel |
| Weight | 131 g (4.62 oz) typical |
| Height | 66.0 mm (2.60 in) |
| Diameter | 25.4 mm (1.00 in) |
| Shipping Weight | 1.0 kg (Estimated) |
| Parameter | Specification |
|---|---|
| Main Loop Output (Pin A ref Pin B) | 4 to 20 mA current loop, Velocity vibration |
| Excitation Voltage | 12 to 30 Vdc (current limited to 40 mA) |
| Settling Time | Less than 15 seconds within 2% of final value |
| Dynamic Output Sensitivity (Pin C ref Pin B) | 10.2 mV/m/s² (100 mV/g) ±20% |
| Dynamic Output Format | Voltage, Acceleration vibration, unbuffered |
| Dynamic Output Bias Voltage | 2.5 V ±0.1 V |
| Dynamic Full Scale Range | 147 m/s² (15 g's) peak |
| Electrical Isolation | Greater than 10^8 ohms |
| Isolation Breakdown Voltage | 600 Vrms with less than 1 mA leakage current |
| Parameter | Specification |
|---|---|
| Velocity Measurement Range | 0 to 50.8 mm/s (0 to 2.0 in/s) |
| Main Loop Frequency Response | 3 Hz to 1 kHz (180 to 60 kcps) ±10% |
| Main Loop Linearity | ±1% |
| Dynamic Output Frequency Response | 2.5 Hz to 10 kHz (150 cpm to 600 kcps) ±10% |
| Mounted Resonant Frequency | Greater than 12 kHz |
| Transverse Sensitivity | Less than 5% of sensitivity |
| Parameter | Specification |
|---|---|
| Operating Temperature Range | -40 degC to +85 degC (-40 degF to +185 degF) |
| Relative Humidity | To 100% non-submerged |
| Sensor Seal | Hermetically sealed |
| Shock Survivability | 9,810 m/s² (1,000 g peak) maximum drop test |
| Magnetic Field Sensitivity (Velocity) | Less than 20 um/s/gauss (790 uin/s/gauss) peak |
| Magnetic Field Sensitivity (Acceleration) | Less than 14.7 mm/s²/gauss (150 ug/gauss) peak |
| Connector Pin | Signal Description |
|---|---|
| Pin A | 4-20 mA Positive Loop (12 to 30 Vdc Loop Power) |
| Pin B | 4-20 mA Negative Loop / Common return for Dynamic Signal |
| Pin C | Dynamic Signal Output (Unbuffered acceleration voltage, referenced to Pin B) |
Wiring Precaution: The Dynamic Signal Negative (Pin B) requires complete isolation from earth ground. If Pin B is inadvertently grounded, the 4 to 20 mA loop will short-circuit, resulting in zero current output.
| Certification / Standard | Scope & Rating |
|---|---|
| FCC | Complies with Part 15 of FCC Rules |
| EMC | European Directive 2014/30/EU |
| RoHS | European Directive 2011/65/EU |
| Maritime | DNV rules for classification (Ships, High speed & light craft, Offshore standards) |
| cNRTLus |
Ex nL IIC T4; AEx nA IIC T4 (Class I, Div 2, Groups A, B, C, D) Ex ia IIC T4; AEx ia IIC T4 (Class I, Div 1, Groups A, B, C, D; Class II, Div 1, Groups E, F, G; Class III, Div 1) |
| ATEX / IECEx |
II 1G Ex ia IIC T4 Ga (Zone 0/1) II 3G Ex nA IIC T4 Gc (Zone 2) Operating Temperature: Ta = -40 degC to +80 degC |
Global Express Shipping
Returns & Warranty
Orders are processed and delivered Monday-Friday (excluding public holidays).
For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .
| Color pattern |
Silver
|
| Country of origin |
United States
|
| Power source |
DC Power
|