Bently Nevada

Bently Nevada 330103-00-14-10-02-05 3300 XL 8 mm Proximity Probe

SKU 330103-00-14-10-02-05

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Bently Nevada

  • Product No.: 330103-00-14-10-02-05

  • Country of origin:United States

  • Product Type: 3300 XL 8 mm Proximity Probe

  • Barcode: 8537101190

  • Payment: T/T, Western Union

  • Weight: 150g

  • Dimensions: 17 mm x 17 mm x 140 mm (H x W x D)

  • Shipping port: Xiamen

  • Warranty: 12 months

Description

330103-00-14-10-02-05 specifies this 3300 XL 8 mm proximity probe configuration featuring an M10 x 1 metric thread, 0 mm unthreaded length, 140 mm overall case length, and a 1.0 meter total length. This specific configuration uses a standard miniature coaxial ClickLoc connector (Option 02) without a connector protector and is certified under Option 05 for CSA, ATEX, and IECEx hazardous area operations. As an unarmored metric probe, it mounts directly into threaded ports on rotating machinery to measure shaft vibration, axial position, and oil film thickness.

Operating as a non-contact eddy-current transducer, the probe pairs with a 3300 XL Proximitor sensor and a matching extension cable to form a complete transducer system. The total length of 1.0 meter is specifically configured to combine with a 4.0 meter or 8.0 meter extension cable, establishing a calibrated 5.0 meter or 9.0 meter overall system length. By monitoring physical gap variations between the 8.0 mm probe tip and the target shaft, the system outputs an analog voltage directly proportional to the physical displacement.

Features

  • M10 x 1 metric threads with a fully threaded 140 mm case length (Option 14) and 0 mm unthreaded section (Option 00) for deep-reach machinery ports.
  • Unarmored 75 ohm coaxial cable configuration (Option 02) equipped with a miniature coaxial ClickLoc male connector.
  • Calibrated 1.0 meter (3.3 feet) overall probe length (Option 10) intended for integration into 5.0 meter or 9.0 meter system configurations.
  • Hazardous area certification (Option 05) covering ATEX, IECEx, and CSA standards for zone-rated industrial environments.
  • Interchangeable design allowing direct field replacement without recalibration when paired with standard 3300 XL components.

Applications

Typical applications include radial vibration and axial thrust position monitoring on high-speed rotating equipment in petrochemical, power generation, and natural gas industries. It is commonly installed in steam turbines, gas turbines, centrifugal compressors, gearboxes, and large industrial pumps to monitor shaft movement and prevent catastrophic machinery damage.

Ordering Information

Option / Segment Code Value Meaning / Configuration
Base Model 330103 3300 XL 8 mm Proximity Probe, M10 x 1 thread, without armor
A - Unthreaded Length 00 0 mm unthreaded length (fully threaded body)
B - Overall Case Length 14 140 mm overall case length (ordered in 10 mm increments)
C - Total Length 10 1.0 meter (3.3 feet) total length
D - Connector/Cable Option 02 Miniature coaxial ClickLoc connector, standard cable
E - Agency Approval 05 CSA, ATEX, IECEx hazardous area approvals

Technical Specifications

Manufacturer Bently Nevada (Baker Hughes)
Part Number 330103-00-14-10-02-05
Product Series 3300 XL 8 mm Proximity Transducer System
Thread Type Metric M10 x 1 (fully threaded)
Case Length 140 mm
Unthreaded Length 0 mm
Cable Type 75 ohm coaxial, standard, unarmored
Cable Length 1.0 meter (3.3 feet)
Connector Type Miniature coaxial ClickLoc male connector
Scale Factor 7.87 V/mm (200 mV/mil) when paired with 3300 XL Proximitor sensor
Linear Range 2.0 mm (80 mils), starting at 0.25 mm (10 mils) from the probe tip
Operating Temperature -52 degC to +177 degC
Excitation Voltage Requires -17.5 Vdc to -26 Vdc (supplied by Proximitor sensor)
Max Thread Torque 15 N-m (11 ft-lb)
Weight 0.15 kg
Dimensions 17 mm x 17 mm x 140 mm (H x W x D)

Installation Guidelines

To establish successful installation, maintain a minimum spacing of at least 40 mm between adjacent proximity probe tips to prevent electromagnetic cross-talk. When threading the M10 x 1 probe body into the machine casing, do not exceed the maximum tightening torque of 15 N-m. Hand-tighten the ClickLoc coaxial connection first, then slide the connector sleeve to lock. Ensure that the coaxial cable bend radius is at least 25 mm to prevent mechanical fatigue or conductor breakages under machine casing vibration.

Compliance and Certifications

  • CSA: Class I, Division 1, Groups A, B, C, D; Class II, Groups E, F, G; Class III
  • ATEX: II 1 G Ex ia IIC T4/T5 Ga
  • IECEx: Ex ia IIC T4/T5 Ga
  • CE Mark: Compliant with European electromagnetic compatibility (EMC) directives
  • RoHS: Compliant with restriction of hazardous substances

FAQ

What does the 14 case length option represent on this 330103 probe?

The 14 overall case length option designates a metric length of 140 mm, calculated in 10 mm increments. This allows the probe tip to extend through deep machinery casings to establish the correct target shaft gap.

Is the coaxial cable on this probe armored?

No, this probe features a standard unarmored coaxial cable (Option 02) with a miniature ClickLoc connector. If you require stainless steel armor shielding, you must specify the 330104 base model instead.

What agency approvals are included with the 330103-00-14-10-02-05 configuration?

This probe configuration is specified with Option 05 approvals, providing compliance certifications for CSA, ATEX, and IECEx hazardous area installations.

View all FAQs →

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

Bently Nevada 330103-00-14-10-02-05 3300 XL 8 mm Proximity Probe

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 3
Only 7 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
United States

Technical knowledge

Replacing ABB DSQC 351: Controller and Network Checks

Checks to record before replacing ABB 3HNE 00006-1 DSQC 351: controller generation, X3/X5/X20/X21 wiring, DeviceNet settings, INTERBUS mapping, and LED states.

IC693CPU360 vs IC693CPU364: Ethernet and Power Budget

Compare the IC693CPU360 and IC693CPU364 by Ethernet interface, +5 VDC load, memory, rack limits, and replacement checks.

1756-OF4 Output Wrong? Check Mode, RTB, and Scaling First

A field-first diagnostic sequence for 1756-OF4 analog output problems: channel mode, removable terminal block, scaling, and controlled electrical checks.

1746-OA8 vs 1746-OA16: Output Count and Current Limits

A direct comparison of 1746-OA8 and 1746-OA16 output count, common grouping, backplane current and temperature-derated load limits.

Replacing a 1761-NET-DNI: Capture These Settings First

A field checklist for recording the 1761-NET-DNI hardware series, firmware, EDS file, DF1 settings, DeviceNet address and messaging configuration before replacement.

EL3062 vs EL3062-0030: The Input Range Changes

The EL3062 is a 0–10 V EtherCAT terminal. The EL3062-0030 is a 0–30 V variant. This checklist covers identification, scaling and commissioning.