330105-02-12-05-12-05 specifies a 3300 XL 8 mm reverse mount proximity probe featuring a 0.2 in unthreaded length (Option 02), 1.2 in overall case length (Option 12), a 0.5 meter total length (Option 05), a specialized FluidLoc cable with ClickLoc coaxial connector (Option 12), and CSA/ATEX/IECEx hazardous area agency approvals (Option 05).
This specific configuration incorporates a FluidLoc cable (Option 12), which is designed to prevent liquid or oil leakage along the interior of the cable jacketing into surrounding areas. This is particularly critical in applications where standard cable configurations (such as Option 02) cannot prevent oil or fluid bypass. With its reverse mount form factor and 3/8-24 UNF-2A threads, this probe is installed from the rear of the machine housing, making it highly suitable for confined spaces and heavy industrial turbine or compressor casing assemblies.
| Option Segment | Selected Code | Specification Meaning |
|---|---|---|
| Orderable Part Number | 330105-02-12-05-12-05 | 3300 XL 8 mm Reverse Mount Proximity Probe, 3/8-24 UNF thread |
| Segment A - Unthreaded Length | 02 | 0.2 in (5.0 mm) unthreaded body length |
| Segment B - Case Length | 12 | 1.2 in (30 mm) overall case length |
| Segment C - Total Length | 05 | 0.5 meter (1.6 feet) cable length |
| Segment D - Connector/Cable | 12 | Miniature coaxial ClickLoc connector, FluidLoc cable |
| Segment E - Agency Approval | 05 | CSA, ATEX, and IECEx hazardous area approvals |
| Suffix Option | (None) | Standard international configuration (does not include -CN China hazardous area approval package) |
| Manufacturer | Bently Nevada |
| Part Number | 330105-02-12-05-12-05 |
| Product Type | 3300 XL 8 mm Reverse Mount Proximity Probe |
| Thread Size | 3/8-24 UNF-2A |
| Unthreaded Length | 0.2 in (5.0 mm) |
| Case Length | 1.2 in (30 mm) |
| Total Length | 0.5 m (1.6 ft) |
| Cable Type | FluidLoc coaxial cable (prevents internal fluid leakage) |
| Connector Type | Miniature ClickLoc coaxial connector (gold-plated) |
| Target Material | AISI 4140 steel (standard calibration target) |
| Nominal Resistance | 7.45 ohms +/- 0.50 ohms (center to outer conductor) |
| Operating Temperature | -52 degC to +177 degC (-62 degF to +350 degF) |
| Pressure Sealing | Seals differential pressure between probe tip and case using a Viton O-ring |
| Recommended Torque | Finger tight (for 3300 XL gold click type connectors) |
| Weight | 0.16 kg |
| Dimensions | 12 mm x 12 mm x 530 mm (H x W x D) |
When installing the reverse mount probe, thread engagement should be monitored carefully to prevent binding. Ensure the coaxial connectors are tightened finger-tight only (for gold ClickLoc type). Route the FluidLoc cable securely through the designated probe sleeve or conduit to prevent mechanical wear. Proper isolation and grounding of the shield are recommended to maintain signal integrity.
Agency Approvals: CSA, ATEX, and IECEx (Intrinsically Safe and Non-Incendive classifications for Class I, Division 1/2 and Zone 0/1/2 environments). Standard international package (does not include -CN NEPSI/CCC China hazardous area package).
Global Express Shipping
Returns & Warranty



330105-02-12-05-12-05 specifies a 3300 XL 8 mm reverse mount proximity probe featuring a 0.2 in unthreaded length (Option 02), 1.2 in overall case length (Option 12), a 0.5 meter total length (Option 05), a specialized FluidLoc cable with ClickLoc coaxial connector (Option 12), and CSA/ATEX/IECEx hazardous area agency approvals (Option 05).
This specific configuration incorporates a FluidLoc cable (Option 12), which is designed to prevent liquid or oil leakage along the interior of the cable jacketing into surrounding areas. This is particularly critical in applications where standard cable configurations (such as Option 02) cannot prevent oil or fluid bypass. With its reverse mount form factor and 3/8-24 UNF-2A threads, this probe is installed from the rear of the machine housing, making it highly suitable for confined spaces and heavy industrial turbine or compressor casing assemblies.
| Option Segment | Selected Code | Specification Meaning |
|---|---|---|
| Orderable Part Number | 330105-02-12-05-12-05 | 3300 XL 8 mm Reverse Mount Proximity Probe, 3/8-24 UNF thread |
| Segment A - Unthreaded Length | 02 | 0.2 in (5.0 mm) unthreaded body length |
| Segment B - Case Length | 12 | 1.2 in (30 mm) overall case length |
| Segment C - Total Length | 05 | 0.5 meter (1.6 feet) cable length |
| Segment D - Connector/Cable | 12 | Miniature coaxial ClickLoc connector, FluidLoc cable |
| Segment E - Agency Approval | 05 | CSA, ATEX, and IECEx hazardous area approvals |
| Suffix Option | (None) | Standard international configuration (does not include -CN China hazardous area approval package) |
| Manufacturer | Bently Nevada |
| Part Number | 330105-02-12-05-12-05 |
| Product Type | 3300 XL 8 mm Reverse Mount Proximity Probe |
| Thread Size | 3/8-24 UNF-2A |
| Unthreaded Length | 0.2 in (5.0 mm) |
| Case Length | 1.2 in (30 mm) |
| Total Length | 0.5 m (1.6 ft) |
| Cable Type | FluidLoc coaxial cable (prevents internal fluid leakage) |
| Connector Type | Miniature ClickLoc coaxial connector (gold-plated) |
| Target Material | AISI 4140 steel (standard calibration target) |
| Nominal Resistance | 7.45 ohms +/- 0.50 ohms (center to outer conductor) |
| Operating Temperature | -52 degC to +177 degC (-62 degF to +350 degF) |
| Pressure Sealing | Seals differential pressure between probe tip and case using a Viton O-ring |
| Recommended Torque | Finger tight (for 3300 XL gold click type connectors) |
| Weight | 0.16 kg |
| Dimensions | 12 mm x 12 mm x 530 mm (H x W x D) |
When installing the reverse mount probe, thread engagement should be monitored carefully to prevent binding. Ensure the coaxial connectors are tightened finger-tight only (for gold ClickLoc type). Route the FluidLoc cable securely through the designated probe sleeve or conduit to prevent mechanical wear. Proper isolation and grounding of the shield are recommended to maintain signal integrity.
Agency Approvals: CSA, ATEX, and IECEx (Intrinsically Safe and Non-Incendive classifications for Class I, Division 1/2 and Zone 0/1/2 environments). Standard international package (does not include -CN NEPSI/CCC China hazardous area package).