Bently Nevada

Bently Nevada 330703-000-040-50-11-00 3300 XL 11 mm Proximity Probe

SKU 330703-000-040-50-11-00

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Bently Nevada

  • Product No.: 330703-000-040-50-11-00

  • Country of origin:United States

  • Product Type: 3300 XL 11 mm Proximity Probe

  • Barcode: 8537101190

  • Payment: T/T, Western Union

  • Weight: 180g

  • Dimensions: 50 mm x 100 mm x 100 mm (H x W x D)

  • Shipping port: Xiamen

  • Warranty: 12 months

Description

Unarmored M14 x 1.5 threaded probe body (Option 000) with a 40 mm case length (Option 040) and a 5.0 m total cable length (Option 50) specifies the 330703-000-040-50-11-00 3300 XL 11 mm Proximity Probe. This non-contacting eddy-current sensor is utilized within 3300 XL 11 mm monitoring chains to measure shaft displacement, dynamic vibration, or static axial position relative to fluid film bearings.

This metric-threaded configuration differs from common imperial-threaded models (such as the 330701 series) and armored variations (such as the 330704 series) by featuring a bare, unarmored FEP-insulated coaxial cable. Equipped with Option 11, it incorporates a specialized FluidLoc cable to block process fluid leakage migration along the internal conductor spacing, paired with an integrated coaxial connector protector designed for wet or high-humidity installations. The 5.0 m total system length matches the electrical calibration requirements of a 5.0 m Proximitor Sensor, allowing direct termination without an intermediary extension cable.

Features

  • Metric M14 x 1.5 threaded steel probe body without external protective armor
  • Option 000 fully threaded design providing 0 mm unthreaded length
  • Option 040 providing 40 mm total case length for shallow thread engagement
  • Option 50 providing a 5.0 m (16.4 feet) integrated triaxial cable length
  • Option 11 FluidLoc cable style to prevent oil and fluid migration through the cable interior
  • Gold-plated brass ClickLoc coaxial connector with pre-installed fluorosilicone connector protector
  • Calibrated for standard AISI 4140 steel target surfaces

Applications

  • Axial (thrust) position measurements on large steam and gas turbines
  • Ramp differential expansion measurements on industrial power generation turbines
  • Rod position or rod drop monitoring on reciprocating compressors
  • Radial vibration and shaft positioning on heavy rotating machinery
  • Keyphasor phase reference and zero-speed tachometer signals

Ordering Information

Option / Segment Position Code on This SKU Meaning / Configuration Detail
Orderable Part Number 330703-000-040-50-11-00 3300 XL 11 mm Proximity Probe, M14 x 1.5 metric thread, without armor
AAA - Unthreaded Length Option 000 0 mm unthreaded length (fully threaded)
BBB - Overall Case Length Option 040 40 mm overall case length
CC - Total Length Option 50 5.0 meters (16.4 feet) total length
DD - Connector & Cable Option 11 Miniature coaxial ClickLoc connector with connector protector, FluidLoc cable
EE - Agency Approval Option 00 Approvals not required

Technical Specifications

Parameter Group Specification / Metric Value
Manufacturer Bently Nevada (Baker Hughes)
Base Model 330703 (M14 x 1.5 Thread, Unarmored)
Probe Tip Diameter 11 mm
Probe Case Material AISI 304 stainless steel (SST)
Probe Tip Material Polyphenylene sulfide (PPS)
Cable Construction 75 ohm triaxial, FEP insulated, FluidLoc style
Connector Material Gold-plated brass ClickLoc miniature coaxial (male)
Connector Protector Fluorosilicone material (pre-installed on cable end)
Linear Range 4.0 mm (160 mils), beginning at approximately 0.5 mm (20 mils) from the target
Output Range Approximately -1 to -17 Vdc over linear range
Incremental Scale Factor (ISF) 3.94 V/mm (100 mV/mil) +/-10% (measured in 0.5 mm increments)
System Frequency Response 0 to 8 kHz: +0, -3 dB typical (with up to 305 meters of field wiring)
Recommended Gap Setting 2.5 mm (100 mils)
Probe dc Resistance 7.2 +/-0.8 ohms (center to outer conductor for 5.0 m probe)
Operating and Storage Temperature -52 degC to +177 degC (-62 degF to +351 degF)
Pressure Seal Rating Viton O-ring sealed (exposure below -34 degC / -30 degF can affect seal integrity)
Relative Humidity 100% condensing, non-submersible when connectors are protected
Maximum Installation Torque 63.3 N-m (560 in-lb)
Recommended Installation Torque 21.1 N-m (187 in-lb)
Maximum Thread Engagement Limit 21 mm
Minimum Cable Bend Radius 25.4 mm (1.0 in)
Maximum Tensile Rating 330 N (75 lb) probe case to probe lead connection

Installation Guidelines

  • Position the probe to the nominal gap of 2.5 mm (100 mils) from the target surface, corresponding to the electrical midpoint of the linear range.
  • Tighten the M14 x 1.5 thread body utilizing the integrated wrench flats. Torque to the recommended 21.1 N-m (187 in-lb) and do not exceed the maximum limit of 63.3 N-m (560 in-lb).
  • Maintain a minimum cable routing bend radius of 25.4 mm (1.0 in) to prevent internal coaxial conductor degradation.
  • Avoid installing with thread engagement lengths exceeding 21 mm to prevent binding during mounting.
  • Ensure the pre-installed connector protector is fully seated and dry before completing the coaxial interface.

Compliance and Certifications

  • Electromagnetic Compatibility (EMC): European Community Directive 2014/30/EU
  • EMC Standards: EN 61000-6-2 (Immunity), EN 61000-6-4 (Emissions)
  • Restriction of Hazardous Substances (RoHS): European Community Directive 2011/65/EU
  • Damp Heat Resistance: Tested in accordance with IEC 68-2-3 standards

FAQ

What does the FluidLoc cable option (Option 11) provide on this probe?

The FluidLoc cable option prevents oil, water, or other process liquids from leaking out of the machine housing through the interior of the probe cable, which is critical in wet, humid, or pressurized environments.

Does this 5.0-meter probe require an extension cable?

No. When using a 5.0-meter probe (Option 50), it connects directly to a 5.0-meter 3300 XL Proximitor Sensor. Adding an extension cable is not required and would cause calibration errors.

What is the recommended installation torque for this M14 x 1.5 threaded probe?

The recommended installation torque is 21.1 N-m (187 in-lb). Do not exceed the maximum rated torque of 63.3 N-m (560 in-lb) to avoid stripping or body deformation.

What are the physical dimensions of the 330703-000-040-50-11-00 probe body?

This probe features a metric M14 x 1.5 threaded body that is fully threaded (0 mm unthreaded length, Option 000) with an overall case length of 40 mm (Option 040).

View all FAQs →

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

Bently Nevada 330703-000-040-50-11-00 3300 XL 11 mm Proximity Probe

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 3
Only 7 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
United States

Technical knowledge

Moving TwinCAT 3 Licenses with C9900-L100: Build and Device Checks

Before moving a TwinCAT 3 license with a Beckhoff C9900-L100, verify the TwinCAT build, XML device description, exact order code and cabinet limits.

Replacing a Beckhoff EL4032: Wiring and Output Checks

A field checklist for replacing a Beckhoff EL4032, covering the ±10 V load, terminal map, power contacts, EtherCAT state, and watchdog behavior.

Replacing Yokogawa AAI835: Wiring and Barrier Checks Before Swap

Before replacing a Yokogawa AAI835, verify the 4-in/4-out channel map, power-loss loop behavior, barrier type, output load, cable, and redundancy.

ABB PM891K01 Replacement: Check Redundancy Before Ordering

ABB PM891K01 article 3BSE053241R1 is the non-redundant AC 800M processor kit. Use this field checklist before replacement.

ABB TP853 Replacement Checks for CI853/CI855/CI857/CI861

Replacement checks for ABB TP853 3BSE018126R1: identify the installed CI853, CI855, CI857, or CI861 interface, record wiring, and verify communication after installation.

5069-L330ERMS2 Startup Checks: RTBs, I/O, and Motion Limits

Engineering checks for the Allen-Bradley 5069-L330ERMS2: controller capacity, separate RTB kits, local I/O limits, network-node limits, and motion-axis count.