Description

The General Electric IC200MDL330 is a 16-point discrete isolated output module designed for use within the VersaMax I/O system family. This high-density output module provides reliable switching capabilities for industrial automation applications, requiring an external 120VAC power supply to energize connected loads. Intelligent processing and communication functions are handled directly by the system CPU or Network Interface Unit (NIU).

Engineered for safety and operational reliability, the IC200MDL330 features robust optical isolation between field outputs and internal logic, as well as group-to-group and point-to-point isolation barriers. Built-in LED indicators provide clear visual feedback, displaying individual point ON/OFF states alongside a dedicated backplane power status indicator.

Features

  • 16 isolated discrete output channels
  • External power supply rating of 85 to 132VAC (47 to 63Hz) at 120VAC nominal
  • Robust isolation: 250VAC continuous and 1500VAC for 1 minute (user input to logic, group-to-group, and point-to-point)
  • Individual green logic-driven LED indicators for each output point
  • Dedicated OK LED for backplane power status monitoring
  • Built-in snubber circuits and MOVs for output protection against transient overvoltages
  • DIN rail mounting compatibility within the VersaMax modular architecture

Applications

  • Discrete actuator control (solenoids, contactors, and indicator lamps)
  • AC motor starter interfacing
  • Industrial manufacturing assembly lines
  • Process control and packaging machinery
  • Distributed I/O drops in hazardous location environments (Class I, Division 2)

Technical Specifications

Parameter Specification
Manufacturer General Electric
Catalog Number / Model IC200MDL330
Product Family VersaMax I/O
Number of Outputs 16 isolated outputs
Output Voltage Range 85 to 132 VAC (47 to 63Hz)
Load Current per Point 10mA minimum to 0.5A maximum
Inrush Current 5.0A maximum for one cycle (20ms)
Output Voltage Drop 2.0V maximum
Output Leakage Current Less than 2mA at 132VAC
Response Time Less than 1/2 cycle maximum (on and off)
Backplane Current Consumption 140mA maximum (5V output)
Isolation Rating 250VAC continuous; 1500VAC for 1 min (optical logic, group-to-group, point-to-point)
Module ID Code 88408840
Country of Origin United States

Connections / Interfaces

  • Field wiring terminals accommodate two-row or three-row terminal carriers
  • Terminals A1 through A16 handle Outputs 1 through 8 and their respective returns
  • Terminals B1 through B16 handle Outputs 9 through 16 and their respective returns

Installation Guidelines

  • Ensure all external power is disconnected before installing, wiring, or replacing modules in hazardous or non-hazardous locations.
  • When connecting output channels to inductive loads, use external suppression circuits (such as MOV or RC networks) to prolong relay and switch contact life.
  • Observe thermal derating guidelines regarding ambient temperature and the number of points active simultaneously to prevent module overheating.
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
FAQ
What is the output voltage rating for the IC200MDL330?
The module operates with an external power supply of 85 to 132VAC (47 to 63Hz) at 120VAC nominal, supporting load currents up to 0.5A maximum per point.
How many output points does the IC200MDL330 provide?
The IC200MDL330 provides 16 isolated discrete output points.
What kind of isolation does this VersaMax module feature?
It features 250VAC continuous and 1500VAC for 1 minute isolation across user input to logic, group-to-group, and point-to-point barriers.
How much backplane current does the IC200MDL330 consume?
The module consumes a maximum of 140mA from the 5V backplane output.
Reviews

IC200MDL330

Stock & lead time on request

Call
1 of 1

General Electric IC200MDL330 VersaMax Discrete Isolated Output Module

Only 14 item(s) left in stock
  • Manufacturer: General Electric

  • Product No.: IC200MDL330

  • Country of origin:United States

  • Product Type: Output Module

  • Payment: T/T, Western Union

  • Weight: 200g

  • Dimensions: 11.5 x 7.0 x 5.0 cm

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantity
View full details

Product Description

Description

The General Electric IC200MDL330 is a 16-point discrete isolated output module designed for use within the VersaMax I/O system family. This high-density output module provides reliable switching capabilities for industrial automation applications, requiring an external 120VAC power supply to energize connected loads. Intelligent processing and communication functions are handled directly by the system CPU or Network Interface Unit (NIU).

Engineered for safety and operational reliability, the IC200MDL330 features robust optical isolation between field outputs and internal logic, as well as group-to-group and point-to-point isolation barriers. Built-in LED indicators provide clear visual feedback, displaying individual point ON/OFF states alongside a dedicated backplane power status indicator.

Features

  • 16 isolated discrete output channels
  • External power supply rating of 85 to 132VAC (47 to 63Hz) at 120VAC nominal
  • Robust isolation: 250VAC continuous and 1500VAC for 1 minute (user input to logic, group-to-group, and point-to-point)
  • Individual green logic-driven LED indicators for each output point
  • Dedicated OK LED for backplane power status monitoring
  • Built-in snubber circuits and MOVs for output protection against transient overvoltages
  • DIN rail mounting compatibility within the VersaMax modular architecture

Applications

  • Discrete actuator control (solenoids, contactors, and indicator lamps)
  • AC motor starter interfacing
  • Industrial manufacturing assembly lines
  • Process control and packaging machinery
  • Distributed I/O drops in hazardous location environments (Class I, Division 2)

Technical Specifications

Parameter Specification
Manufacturer General Electric
Catalog Number / Model IC200MDL330
Product Family VersaMax I/O
Number of Outputs 16 isolated outputs
Output Voltage Range 85 to 132 VAC (47 to 63Hz)
Load Current per Point 10mA minimum to 0.5A maximum
Inrush Current 5.0A maximum for one cycle (20ms)
Output Voltage Drop 2.0V maximum
Output Leakage Current Less than 2mA at 132VAC
Response Time Less than 1/2 cycle maximum (on and off)
Backplane Current Consumption 140mA maximum (5V output)
Isolation Rating 250VAC continuous; 1500VAC for 1 min (optical logic, group-to-group, point-to-point)
Module ID Code 88408840
Country of Origin United States

Connections / Interfaces

  • Field wiring terminals accommodate two-row or three-row terminal carriers
  • Terminals A1 through A16 handle Outputs 1 through 8 and their respective returns
  • Terminals B1 through B16 handle Outputs 9 through 16 and their respective returns

Installation Guidelines

  • Ensure all external power is disconnected before installing, wiring, or replacing modules in hazardous or non-hazardous locations.
  • When connecting output channels to inductive loads, use external suppression circuits (such as MOV or RC networks) to prolong relay and switch contact life.
  • Observe thermal derating guidelines regarding ambient temperature and the number of points active simultaneously to prevent module overheating.
Loading product navigation…

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

General Electric IC200MDL330 VersaMax Discrete Isolated Output Module

What is the output voltage rating for the IC200MDL330?

The module operates with an external power supply of 85 to 132VAC (47 to 63Hz) at 120VAC nominal, supporting load currents up to 0.5A maximum per point.

How many output points does the IC200MDL330 provide?

The IC200MDL330 provides 16 isolated discrete output points.

What kind of isolation does this VersaMax module feature?

It features 250VAC continuous and 1500VAC for 1 minute isolation across user input to logic, group-to-group, and point-to-point barriers.

How much backplane current does the IC200MDL330 consume?

The module consumes a maximum of 140mA from the 5V backplane output.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
United States

Technical knowledge

Filtering Noisy PLC Signals Without Hiding Real Faults

Input filtering can stabilize PLC data, but excessive smoothing delays alarms and masks process changes. Learn how to diagnose noise, select hardware or software filters, and validate response time.

SCR or PWM? Choosing a Drive for Brushed DC Motors

SCR and PWM drives regulate brushed DC motors in different ways. This comparison covers torque quality, speed range, reversal, braking, electrical noise, thermal behavior, feedback, and retrofit...

How Industrial Inverters Build AC From a DC Bus

Industrial inverters synthesize controllable AC from a DC bus through semiconductor switching and filtering. This guide explains H-bridges, PWM, harmonics, motor loads, protection, thermal limits,...

Robot Force Control: From Contact Detection to Stable Process

Force control lets a robot adapt to contact instead of following position alone. This guide compares sensing approaches, control modes, process limits, safety boundaries, commissioning tests, and...

When Sensor-Level Logic Helps—and When It Hides Risk

Configurable sensors can perform window, latch, delay, and Boolean decisions before data reaches a PLC. The benefit is faster local behavior; the risk is hidden logic, weak diagnostics, and...

Connecting GX Simulator to Factory I/O Through OPC

A stable Mitsubishi virtual commissioning setup requires more than matching addresses. This guide explains the GX Simulator–OPC–Factory I/O data path, namespace design, scan timing, validation, and...