General Electric

General Electric IS200TRLYS1B Mark VIe Relay Output Terminal Board

SKU IS200TRLYS1B

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: General Electric

  • Product No.: IS200TRLYS1B

  • Country of origin:United States

  • Product Type: Relay Output Terminal Board

  • Barcode: 8537101190

  • Payment: T/T, Western Union

  • Weight: 2920g

  • Dimensions: 34 x 22.5 x 11.5 cm

  • Shipping port: Xiamen

  • Warranty: 12 months

Description

The General Electric IS200TRLYS1B is a dedicated Relay Output Terminal Board engineered specifically for the GE Mark VIe distributed control system (DCS) architecture. This terminal board functions as a critical interface module, providing reliable electromechanical relay switching for heavy-duty field devices, actuators, solenoids, and alarm circuits within complex industrial automation environments. Designed to operate seamlessly within the Mark VIe platform, it securely bridges the gap between high-level controller logic and high-current plant equipment.

Built for deployment in demanding turbine and industrial control cabinets, the IS200TRLYS1B features integrated terminal blocks for secure field wiring termination and robust galvanic isolation between control logic and field power supplies. The module facilitates precision switching and incorporates diagnostic tracking capabilities to monitor relay health, contact status, and connection integrity. By ensuring rapid execution of discrete output commands, this terminal board directly enhances overall loop reliability, system uptime, and operational safety in continuous-process facilities.

Features

  • Engineered specifically for the General Electric Mark VIe control system architecture
  • Provides multi-channel relay output switching for high-current field actuators and solenoids
  • Integrated terminal blocks for secure, high-density field-wiring termination
  • Robust electrical isolation separating low-voltage control circuitry from high-voltage field loads
  • Built-in diagnostic feedback loops for real-time relay health and contact status monitoring
  • Ruggedized industrial construction designed to withstand harsh operating conditions within control enclosures

Applications

  • Discrete output signal switching for industrial gas and steam turbine control systems
  • Direct actuation of high-current solenoids, valves, and pneumatic control devices
  • Interface management for plant safety alarms and emergency shutdown (ESD) networks
  • Remote rack discrete actuator command processing in distributed control architectures
  • High-load interlock execution in heavy industrial process automation loops

Technical Specifications

Parameter Specification
Brand General Electric
Product Series Mark VIe
Module Type Relay Output Terminal Board
Catalog Number IS200TRLYS1B
Mounting Type Standard Panel / Cabinet Mounting
Terminal Type Fixed Barrier / Plug-in Screw Terminals
Operating Temperature 0 to 60 Celsius
Country of Origin United States

Compliance and Certifications

  • CE Compliant for applicable European Union directives
  • Designed in accordance with industrial standards for DCS and turbine control hardware

FAQ

What control system is the IS200TRLYS1B designed for?

The IS200TRLYS1B is specifically designed for integration into the General Electric Mark VIe distributed control system (DCS) platform.

What is the primary function of the IS200TRLYS1B board?

It functions as a relay output terminal board, providing reliable electromechanical switching to control high-current field devices such as solenoids, actuators, and alarm circuits.

Does the IS200TRLYS1B include diagnostic features?

Yes, the module supports diagnostic feedback tracking to monitor relay health, contact status, and wiring integrity within the Mark VIe network.

How is the IS200TRLYS1B mounted in a control panel?

It is designed for standard cabinet or panel mounting within industrial control enclosures, utilizing integrated terminal blocks for secure field wiring connections.

View all FAQs →

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 3
Only 4 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
United States

Technical knowledge

Engineering Industrial Joystick Controls for Safe Motion

An industrial joystick is only the first element in a safe motion command chain. This guide covers sensing choices, wiring, signal validation, PLC logic, restart behavior, and commissioning for...

Seeing PID Behavior Before Tuning the Loop

PID tuning becomes safer when engineers can see how proportional, integral, and derivative actions reshape error, output, and response over time. This guide turns live trends into a disciplined...

Commissioning a Linear Axis Without Hiding Mechanical Faults

A linear axis should be proven mechanically before aggressive tuning begins. This commissioning workflow covers scaling, direction, limits, homing, STO, low-speed tests, and evidence-based tuning for...

Interposing Relays: Isolation, Load Matching, and Diagnostics

Interposing relays protect PLC and DCS interfaces by separating voltage domains, matching output capacity to field loads, and making faults easier to isolate. This guide explains selection,...

Filtering Noisy PLC Signals Without Hiding Real Faults

Input filtering can stabilize PLC data, but excessive smoothing delays alarms and masks process changes. Learn how to diagnose noise, select hardware or software filters, and validate response time.

SCR or PWM? Choosing a Drive for Brushed DC Motors