Description

The Honeywell 10208/2/1 is a plug-and-play Relay Output Module designed for discrete switching, interposing control, and signal isolation within the Honeywell Fail Safe Control (FSC) system architecture. Operating as a dedicated I/O component, it bridges the controller's internal logic and field-level actuators, interposing relays, solenoid valves, or alarm circuits requiring dry contact switching.

The module features 10 output channels utilizing physical relay contacts. Built in a standard Eurocard form factor with space requirements of 4 TE, 3 HE (4 HP, 3U), the unit plugs directly into compatible FSC I/O backplanes via its rear card edge interface. Utilizing the 10xxx/2/x series plug-and-play architecture, the Honeywell 10208/2/1 features factory-defined mechanical key coding (Holes A9 and C17) to prevent incorrect module insertion and protect system wiring integrity.

Features

  • 10 Isolated Output Channels: Provides 10 independent relay contact outputs for discrete switching and interposing control applications.
  • Plug-and-Play Architecture: Belongs to the 10xxx/2/x hardware release series, supporting keyed insertion into system backplanes without hardwired rack-connector I/O loops.
  • Mechanical Key Coding: Factory-assigned coding holes at positions A9 and C17 match corresponding rack pins (A9, C17) to prevent accidental insertion of incorrect module types.
  • Compact Eurocard Form Factor: Requires 4 TE horizontal pitch (4 HP) and 3 HE vertical height (3U) within standard 19-inch FSC I/O racks.
  • Reliable Contact Switching: Ideal for interposing loads, alarm horn/lamp signaling, and galvanic isolation between system logic and external control circuits.

Applications

  • Interposing relay control for solenoid valves, motor starters, and contactors.
  • Field signal isolation and potential-free dry contact switching.
  • Annunciator, alarm horn, and status lamp drive circuits.
  • Emergency shutdown (ESD) auxiliary switching and process interlocking interface.

Technical Specifications

Parameter Specification
Manufacturer Honeywell
Model 10208/2/1
Product Type Relay Output Module
Architecture / Series FSC 10xxx/2/x (Plug-and-Play)
Output Channels 10
Output Type Relay Contact
Form Factor / Space Requirements 4 TE, 3 HE (4 HP, 3U)
Module Key Coding (Holes) A9, C17
Matching Rack Key Coding (Pins) A9, C17
Storage Temperature -25 degC to +80 degC
Operating Temperature 0 degC to 60 degC
Relative Humidity 95% non-condensing
Vibration (Sinusoidal) 10-57 Hz: 0.075 mm displacement; 57-150 Hz: 1 G (3 axes)
Shock Resistance 15 G (11 ms duration, 3 axes)

Installation Guidelines

  1. Pre-Installation Inspection: Visually inspect the module for physical damage. Ensure the SOURIAU 5159 coding holes at positions A9 and C17 are clean and undamaged.
  2. Rack Verification: Confirm that the targeted slot on the I/O backplane (such as 10314/1/1 or 10315/1/1) is prepared with matching mechanical guide pins at A9 and C17. Never force a module into a slot if resistance is encountered, as this indicates a keying mismatch.
  3. Power Down & ESD Precautions: Before inserting or removing modules, observe ESD safe handling practices. Ensure rack power supply conditions adhere to system maintenance procedures.
  4. Insertion: Align the card edge guides carefully into the top and bottom rails of the 3U rack slot. Slide the module firmly inward until the rear connector seats fully into the backplane receptacle. Secure top and bottom retaining screws to ensure proper grounding and mechanical locking against vibration.
  5. Field Termination: Ensure that interconnecting cables and Field Termination Assemblies (FTAs) or terminal blocks matched to the relay output channels are wired per project schematics before energizing load circuits.
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
FAQ
What is the primary function of the Honeywell 10208/2/1 module?
The module provides 10 independent relay contact output channels for switching, interposing, and potential-free signal isolation between the FSC system logic and external field devices.
How does the 10208/2/1 differ from non plug-and-play FSC relay modules?
As a 10xxx/2/x series module, the 10208/2/1 features plug-and-play functionality with factory-defined mechanical key coding (holes at A9 and C17), simplifying installation compared to hardwired 10xxx/1/x series modules.
What physical space is required to install the Honeywell 10208/2/1 module?
The module requires 4 TE horizontal width (4 HP) and 3 HE vertical height (3U) within a standard Honeywell FSC 19-inch I/O rack or backplane assembly.
What key coding configuration is required on the backplane slot for this module?
The module connector is factory-coded with holes at positions A9 and C17. The corresponding rack connector slot must be equipped with large coding pins at positions A9 and C17 to allow proper insertion.
Reviews

10208/2/1

Stock & lead time on request

Call
1 of 3

Honeywell 10208/2/1 Fail Safe Control Relay Output Module

Only 8 item(s) left in stock
  • Manufacturer: Honeywell

  • Product No.: 10208/2/1

  • Country of origin:United States

  • Product Type: Relay Output Module

  • Payment: T/T, Western Union

  • Weight: 3000g

  • Dimensions: 20 x 130 x 262 mm

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantity
View full details

Description

The Honeywell 10208/2/1 is a plug-and-play Relay Output Module designed for discrete switching, interposing control, and signal isolation within the Honeywell Fail Safe Control (FSC) system architecture. Operating as a dedicated I/O component, it bridges the controller's internal logic and field-level actuators, interposing relays, solenoid valves, or alarm circuits requiring dry contact switching.

The module features 10 output channels utilizing physical relay contacts. Built in a standard Eurocard form factor with space requirements of 4 TE, 3 HE (4 HP, 3U), the unit plugs directly into compatible FSC I/O backplanes via its rear card edge interface. Utilizing the 10xxx/2/x series plug-and-play architecture, the Honeywell 10208/2/1 features factory-defined mechanical key coding (Holes A9 and C17) to prevent incorrect module insertion and protect system wiring integrity.

Features

  • 10 Isolated Output Channels: Provides 10 independent relay contact outputs for discrete switching and interposing control applications.
  • Plug-and-Play Architecture: Belongs to the 10xxx/2/x hardware release series, supporting keyed insertion into system backplanes without hardwired rack-connector I/O loops.
  • Mechanical Key Coding: Factory-assigned coding holes at positions A9 and C17 match corresponding rack pins (A9, C17) to prevent accidental insertion of incorrect module types.
  • Compact Eurocard Form Factor: Requires 4 TE horizontal pitch (4 HP) and 3 HE vertical height (3U) within standard 19-inch FSC I/O racks.
  • Reliable Contact Switching: Ideal for interposing loads, alarm horn/lamp signaling, and galvanic isolation between system logic and external control circuits.

Applications

  • Interposing relay control for solenoid valves, motor starters, and contactors.
  • Field signal isolation and potential-free dry contact switching.
  • Annunciator, alarm horn, and status lamp drive circuits.
  • Emergency shutdown (ESD) auxiliary switching and process interlocking interface.

Technical Specifications

Parameter Specification
Manufacturer Honeywell
Model 10208/2/1
Product Type Relay Output Module
Architecture / Series FSC 10xxx/2/x (Plug-and-Play)
Output Channels 10
Output Type Relay Contact
Form Factor / Space Requirements 4 TE, 3 HE (4 HP, 3U)
Module Key Coding (Holes) A9, C17
Matching Rack Key Coding (Pins) A9, C17
Storage Temperature -25 degC to +80 degC
Operating Temperature 0 degC to 60 degC
Relative Humidity 95% non-condensing
Vibration (Sinusoidal) 10-57 Hz: 0.075 mm displacement; 57-150 Hz: 1 G (3 axes)
Shock Resistance 15 G (11 ms duration, 3 axes)

Installation Guidelines

  1. Pre-Installation Inspection: Visually inspect the module for physical damage. Ensure the SOURIAU 5159 coding holes at positions A9 and C17 are clean and undamaged.
  2. Rack Verification: Confirm that the targeted slot on the I/O backplane (such as 10314/1/1 or 10315/1/1) is prepared with matching mechanical guide pins at A9 and C17. Never force a module into a slot if resistance is encountered, as this indicates a keying mismatch.
  3. Power Down & ESD Precautions: Before inserting or removing modules, observe ESD safe handling practices. Ensure rack power supply conditions adhere to system maintenance procedures.
  4. Insertion: Align the card edge guides carefully into the top and bottom rails of the 3U rack slot. Slide the module firmly inward until the rear connector seats fully into the backplane receptacle. Secure top and bottom retaining screws to ensure proper grounding and mechanical locking against vibration.
  5. Field Termination: Ensure that interconnecting cables and Field Termination Assemblies (FTAs) or terminal blocks matched to the relay output channels are wired per project schematics before energizing load circuits.
Loading product navigation…

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

Honeywell 10208/2/1 Fail Safe Control Relay Output Module

What is the primary function of the Honeywell 10208/2/1 module?

The module provides 10 independent relay contact output channels for switching, interposing, and potential-free signal isolation between the FSC system logic and external field devices.

How does the 10208/2/1 differ from non plug-and-play FSC relay modules?

As a 10xxx/2/x series module, the 10208/2/1 features plug-and-play functionality with factory-defined mechanical key coding (holes at A9 and C17), simplifying installation compared to hardwired 10xxx/1/x series modules.

What physical space is required to install the Honeywell 10208/2/1 module?

The module requires 4 TE horizontal width (4 HP) and 3 HE vertical height (3U) within a standard Honeywell FSC 19-inch I/O rack or backplane assembly.

What key coding configuration is required on the backplane slot for this module?

The module connector is factory-coded with holes at positions A9 and C17. The corresponding rack connector slot must be equipped with large coding pins at positions A9 and C17 to allow proper insertion.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Dots
Country of origin
United States
Power source
DC Power

Recently Viewed Products

Technical knowledge

Implementing 3-Switch XOR Ladder Logic with Internal Bit

Implement a 3-SPST switch XOR light circuit in LogixPro or RSLogix 500 using an internal relay bit. Includes truth tables, boolean equations, and verified.

Building a Modbus RTU Network with CompactLogix and DeltaV

Integrate Allen-Bradley CompactLogix, Caterpillar ATS, and generators into DeltaV DCS over Modbus RTU. Covers ProSoft MVI69-MCM, Miille DIN266 gateways.

ONS Instruction Not Energizing OTE in Studio 5000 Ladder Logic

ONS instruction fires but the OTE coil never latches in Studio 5000 because the one-shot is only true for one scan. Use OTL/OTU or seal-in logic instead.

Kinetix 5500 EtherNet/IP Network Switch Requirements and Topology

Configure Allen-Bradley Kinetix 5500 servo drives on EtherNet/IP. Covers CIP Sync, IEEE 1588 V2 timing, Stratix selection, DLR topology, and HMI.

Moving Average Filtering in DCS and PLC Analog Control

A moving-average filter is the sliding-window smoother most instrument engineers drop into DCS and PLC analog paths. Here is how the window works, how N and sample time set lag, and when a...

GE Mark VI Function Blocks for Gas Turbine Control Logic

On Frame 5–9 gas turbines, GE Mark VI and Mark VIe run control as function-block application software. This article maps process, protection, and sequencing functions—and what Toolbox ST access...