Honeywell

Honeywell 10310/3/1CC Earth Leakage Detector 20.008.211

SKU 10310/3/1CC

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Honeywell
  • Product No.: 10310/3/1CC
  • Origin United States
  • Product Type: Earth Leakage Detectors
  • Payment: T/T, Western Union
  • Weight: 0.35 kg
  • Dimensions: 75 x 55 x 110 mm
  • Shipping port: Xiamen
  • Warranty: 12 months

Tags

Quantity

Product Description

Description

The Honeywell 10310/3/1CC (Part Number 20.008.211) is a compact DIN-rail mounted Earth Leakage Detector designed for real-time monitoring and detection of ground faults in industrial electrical control systems. Engineered under the Haussener Electronic product line for Honeywell safety and control environments, this specialized monitoring relay continuously tracks system insulation resistance and detects leakage current threshold violations (CL > 25 mA) to prevent unexpected operational downtime, equipment damage, and electrical hazards.

Featuring an operating voltage rating of +24V DC, the device includes front-panel diagnostic indicators (LEDs for Fault and Mode status) alongside integrated toggle switches for frequency configuration (1/4 Hz and 1 Hz) and manual Test/Reset operations. Standard screw terminal block connections ensure reliable field wiring for power inputs, earth ground reference points, and dry contact alarm relay outputs.

Features

  • Specialized earth leakage detection for industrial control circuits with a trip threshold rating of CL > 25 mA
  • Front-panel status LEDs providing visual indication for Fault (Red) and Mode (Green) operational status
  • Integrated toggle switch for selectable detection frequency modes (1/4 Hz and 1 Hz)
  • Built-in front-panel toggle switch for manual Test and Reset operations
  • Integrated volt-free contact output for remote alarm signalling and supervisory system integration
  • Screw terminal block interface supporting clear terminal identification (+24V, 0V, Earth connections, and relay contacts)
  • Standard DIN-rail mountable compact enclosure for installation inside industrial control panels

Applications

  • Ground fault monitoring in 24V DC power distribution circuits
  • Protection of industrial control systems, PLC cabinets, and DCS I/O field power lines
  • Continuous insulation monitoring in ungrounded or high-resistance grounded control networks
  • Integration into safety systems where early leakage detection prevents nuisance trips and equipment damage

Technical Specifications

Parameter Specification
Manufacturer Honeywell / Haussener Electronic
Model Number 10310/3/1CC
Part Number 20.008.211
Revision Rev 1.0
Product Type Earth Leakage Detector
Nominal Operating Voltage +24V DC
Leakage Detection Threshold CL > 25 mA
Selectable Frequency Modes 1/4 Hz, 1 Hz
Visual Status Indicators Fault (Red LED), Mode (Green LED)
Local Controls Toggle switch (1/4 Hz / 1 Hz), Toggle switch (Test / Reset)
Output Contact Type Dry Contact Relay Output (Volt-Free Contact)
Mounting Type DIN Rail Mount
Connection Type Screw Terminal Block

Connections / Interfaces

Terminal Marking Function
+24V Power Supply Input (+24V DC)
0V Power Supply Common (0V DC)
Earth1 Primary Earth Reference Connection
Earth. Intermediate Earth Ground Connection
Earth2 Secondary Earth Reference Connection
Relay Terminals Dry Contact Output Terminals for Remote Alarm / Interlock

Installation Guidelines

  1. Verify that the incoming power supply matches the rated +24V DC input specification before energizing the module.
  2. Ensure mains power and field voltages are completely isolated prior to mounting or wiring the unit inside the control cabinet.
  3. Snap the module securely onto a standard DIN rail within a clean, dry, and adequately ventilated enclosure.
  4. Wire the +24V DC supply, earth ground reference connections (Earth1, Earth., Earth2), and dry contact alarm wiring according to system schematics.
  5. Verify tight terminal screw connections to ensure low contact resistance and stable ground monitoring reference.

Configuration / Commissioning / Maintenance

  1. Mode Selection: Set the front-panel toggle switch to the required frequency setting (1/4 Hz or 1 Hz) based on system response requirements.
  2. Functional Testing: Toggle the Test switch to manually simulate a fault condition, confirming that the Fault LED illuminates and the output contact changes state.
  3. System Reset: Toggle the Reset switch following a test or cleared earth fault to restore the detector to normal monitoring mode (indicated by the Mode LED status).
  4. Periodic Inspection: Visually inspect wire terminations and verify diagnostic status LEDs as part of routine preventive maintenance.
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
FAQ
What is the primary function of the Honeywell 10310/3/1CC Earth Leakage Detector?
The Honeywell 10310/3/1CC Earth Leakage Detector is designed to monitor continuous ground insulation and detect leakage currents exceeding 25 mA in 24V DC industrial control circuits, triggering an internal relay contact to alert operators before critical hardware damage or system outages occur.
How do you manually test and reset the Honeywell 10310/3/1CC detector?
The Honeywell 10310/3/1CC features a front-panel toggle switch marked Test/Reset. Moving the switch to the Test position simulates a ground fault condition to test the relay output and Fault LED, while switching to Reset restores normal monitoring status after clearing a fault.
What power supply voltage is required for operating the Honeywell 10310/3/1CC?
The Honeywell 10310/3/1CC operates on a nominal +24V DC power supply connected across the marked +24V and 0V screw terminals on the front connection block.
What do the selectable 1/4 Hz and 1 Hz settings on the Honeywell 10310/3/1CC control?
The front toggle switch on the Honeywell 10310/3/1CC selects the operational measurement cycle frequency between 1/4 Hz and 1 Hz, allowing engineers to adapt the leakage detection sampling rate to specific control loop and grounding system requirements.
Reviews

10310/3/1CC

Stock & lead time on request

Call
1 of 4

Honeywell 10310/3/1CC Earth Leakage Detector 20.008.211

Only 6 item(s) left in stock
  • Manufacturer: Honeywell

  • Product No.: 10310/3/1CC

  • Country of origin:United States

  • Product Type: Earth Leakage Detectors

  • Payment: T/T, Western Union

  • Weight: 350g

  • Dimensions: 75 x 55 x 110 mm

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantity
View full details

Product Description

Description

The Honeywell 10310/3/1CC (Part Number 20.008.211) is a compact DIN-rail mounted Earth Leakage Detector designed for real-time monitoring and detection of ground faults in industrial electrical control systems. Engineered under the Haussener Electronic product line for Honeywell safety and control environments, this specialized monitoring relay continuously tracks system insulation resistance and detects leakage current threshold violations (CL > 25 mA) to prevent unexpected operational downtime, equipment damage, and electrical hazards.

Featuring an operating voltage rating of +24V DC, the device includes front-panel diagnostic indicators (LEDs for Fault and Mode status) alongside integrated toggle switches for frequency configuration (1/4 Hz and 1 Hz) and manual Test/Reset operations. Standard screw terminal block connections ensure reliable field wiring for power inputs, earth ground reference points, and dry contact alarm relay outputs.

Features

  • Specialized earth leakage detection for industrial control circuits with a trip threshold rating of CL > 25 mA
  • Front-panel status LEDs providing visual indication for Fault (Red) and Mode (Green) operational status
  • Integrated toggle switch for selectable detection frequency modes (1/4 Hz and 1 Hz)
  • Built-in front-panel toggle switch for manual Test and Reset operations
  • Integrated volt-free contact output for remote alarm signalling and supervisory system integration
  • Screw terminal block interface supporting clear terminal identification (+24V, 0V, Earth connections, and relay contacts)
  • Standard DIN-rail mountable compact enclosure for installation inside industrial control panels

Applications

  • Ground fault monitoring in 24V DC power distribution circuits
  • Protection of industrial control systems, PLC cabinets, and DCS I/O field power lines
  • Continuous insulation monitoring in ungrounded or high-resistance grounded control networks
  • Integration into safety systems where early leakage detection prevents nuisance trips and equipment damage

Technical Specifications

Parameter Specification
Manufacturer Honeywell / Haussener Electronic
Model Number 10310/3/1CC
Part Number 20.008.211
Revision Rev 1.0
Product Type Earth Leakage Detector
Nominal Operating Voltage +24V DC
Leakage Detection Threshold CL > 25 mA
Selectable Frequency Modes 1/4 Hz, 1 Hz
Visual Status Indicators Fault (Red LED), Mode (Green LED)
Local Controls Toggle switch (1/4 Hz / 1 Hz), Toggle switch (Test / Reset)
Output Contact Type Dry Contact Relay Output (Volt-Free Contact)
Mounting Type DIN Rail Mount
Connection Type Screw Terminal Block

Connections / Interfaces

Terminal Marking Function
+24V Power Supply Input (+24V DC)
0V Power Supply Common (0V DC)
Earth1 Primary Earth Reference Connection
Earth. Intermediate Earth Ground Connection
Earth2 Secondary Earth Reference Connection
Relay Terminals Dry Contact Output Terminals for Remote Alarm / Interlock

Installation Guidelines

  1. Verify that the incoming power supply matches the rated +24V DC input specification before energizing the module.
  2. Ensure mains power and field voltages are completely isolated prior to mounting or wiring the unit inside the control cabinet.
  3. Snap the module securely onto a standard DIN rail within a clean, dry, and adequately ventilated enclosure.
  4. Wire the +24V DC supply, earth ground reference connections (Earth1, Earth., Earth2), and dry contact alarm wiring according to system schematics.
  5. Verify tight terminal screw connections to ensure low contact resistance and stable ground monitoring reference.

Configuration / Commissioning / Maintenance

  1. Mode Selection: Set the front-panel toggle switch to the required frequency setting (1/4 Hz or 1 Hz) based on system response requirements.
  2. Functional Testing: Toggle the Test switch to manually simulate a fault condition, confirming that the Fault LED illuminates and the output contact changes state.
  3. System Reset: Toggle the Reset switch following a test or cleared earth fault to restore the detector to normal monitoring mode (indicated by the Mode LED status).
  4. Periodic Inspection: Visually inspect wire terminations and verify diagnostic status LEDs as part of routine preventive maintenance.
Loading product navigation…

What is the primary function of the Honeywell 10310/3/1CC Earth Leakage Detector?

The Honeywell 10310/3/1CC Earth Leakage Detector is designed to monitor continuous ground insulation and detect leakage currents exceeding 25 mA in 24V DC industrial control circuits, triggering an internal relay contact to alert operators before critical hardware damage or system outages occur.

How do you manually test and reset the Honeywell 10310/3/1CC detector?

The Honeywell 10310/3/1CC features a front-panel toggle switch marked Test/Reset. Moving the switch to the Test position simulates a ground fault condition to test the relay output and Fault LED, while switching to Reset restores normal monitoring status after clearing a fault.

What power supply voltage is required for operating the Honeywell 10310/3/1CC?

The Honeywell 10310/3/1CC operates on a nominal +24V DC power supply connected across the marked +24V and 0V screw terminals on the front connection block.

What do the selectable 1/4 Hz and 1 Hz settings on the Honeywell 10310/3/1CC control?

The front toggle switch on the Honeywell 10310/3/1CC selects the operational measurement cycle frequency between 1/4 Hz and 1 Hz, allowing engineers to adapt the leakage detection sampling rate to specific control loop and grounding system requirements.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
United States

Technical knowledge

1756-L73 Firmware Upgrade Guide: v19 vs v21/v31 Decision

Replacing a 1756-L73 does not automatically mean upgrading its firmware. This guide compares v19.013, v21.011 and v31.011, focusing on project compatibility, HMI communications, legacy networks and...

Implementing 3-Switch XOR Ladder Logic with Internal Bit

Implement a 3-SPST switch XOR light circuit in LogixPro or RSLogix 500 using an internal relay bit. Includes truth tables, boolean equations, and verified.

Building a Modbus RTU Network with CompactLogix and DeltaV

Integrate Allen-Bradley CompactLogix, Caterpillar ATS, and generators into DeltaV DCS over Modbus RTU. Covers ProSoft MVI69-MCM, Miille DIN266 gateways.

ONS Instruction Not Energizing OTE in Studio 5000 Ladder Logic

ONS instruction fires but the OTE coil never latches in Studio 5000 because the one-shot is only true for one scan. Use OTL/OTU or seal-in logic instead.

Kinetix 5500 EtherNet/IP Network Switch Requirements and Topology

Configure Allen-Bradley Kinetix 5500 servo drives on EtherNet/IP. Covers CIP Sync, IEEE 1588 V2 timing, Stratix selection, DLR topology, and HMI.

Moving Average Filtering in DCS and PLC Analog Control

A moving-average filter is the sliding-window smoother most instrument engineers drop into DCS and PLC analog paths. Here is how the window works, how N and sample time set lag, and when a...