Honeywell

Honeywell MC-PHAI01 51403479-150 C300 Analog Input Module

SKU MC-PHAI01 51403479-150

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Honeywell

  • Product No.: MC-PHAI01 51403479-150

  • Country of origin:United States

  • Product Type: Analog Input Modules

  • Barcode: 8537101190

  • Payment: T/T, Western Union

  • Weight: 420g

  • Dimensions: 3.0 cm x 31.8 cm x 27.7 cm

  • Shipping port: Xiamen

  • Warranty: 12 months

Description

The Honeywell MC-PHAI01 (Model 51403479-150) is a specialized analog input module engineered for integration within Honeywell Experion PKS distributed control systems. This C300 series module handles critical signal acquisition tasks, interfacing field transmitters and sensors with higher-level control processors to ensure accurate measurement and loop control across complex industrial processes.

Designed to support high-availability automation architectures, the MC-PHAI01 operates efficiently within demanding process control environments. It features dual I/O link support and consistent execution periods, allowing seamless data exchange and synchronization across the control network. The unit integrates directly into standard Honeywell Series C infrastructure, maintaining system scalability and reliable performance.

Features

  • Native compatibility with Honeywell Experion C300 distributed control system architecture
  • Dual I/O link support configurable for 375 Kbaud (PM) or 750 Kbaud (C Series) communication speeds
  • Supports redundant module configurations for high-availability loops
  • Device index configuration capability ranging from 1 to 510
  • Engineered for standard Series C IOTA mounting and terminal integration

Applications

  • Continuous process manufacturing and chemical production
  • Oil and gas extraction, refining, and distribution
  • Power generation and electrical substation monitoring
  • Water and wastewater treatment facilities

Technical Specifications

Parameter Specification
Manufacturer Honeywell
Product Series Experion C300 / Series C
Exact Model / Part Number MC-PHAI01 / 51403479-150
Module Type Analog Input Module
Base Execution Period 50 ms
I/O Link Speed 375 Kbaud (PM) or 750 Kbaud (C Series)
Redundancy Support Yes (Controller and I/O level)
Mounting Series C IOTA (Input Output Termination Assembly)
Country of Origin United States
Dimensions 3.0 cm x 31.8 cm x 27.7 cm
Net Weight 0.42 kg

Installation Guidelines

  1. Verify the part number and model against system engineering drawings before unboxing.
  2. Ensure all power to the target IOTA and associated cabinet chassis is de-energized before handling hardware.
  3. Inspect the module connectors and pins for any signs of transit damage or debris.
  4. Securely mount the MC-PHAI01 module onto its designated Series C IOTA.
  5. Verify field wiring terminations on the IOTA correspond to loop diagrams.
  6. Restore power, configure the device index via the engineering station, and check diagnostic LED indicators to confirm proper communication.

FAQ

What control system is the Honeywell MC-PHAI01 51403479-150 designed for?

The Honeywell MC-PHAI01 51403479-150 is designed specifically for the Honeywell Experion PKS distributed control system utilizing the C300 controller and Series C I/O architecture.

Does the Honeywell MC-PHAI01 support controller or I/O redundancy?

Yes, the Honeywell MC-PHAI01 51403479-150 supports redundant configurations to maintain uninterrupted operation and high availability in critical industrial processes.

What are the physical dimensions and weight of this analog input module?

The Honeywell MC-PHAI01 51403479-150 measures approximately 3.0 cm x 31.8 cm x 27.7 cm and has a net weight of 0.42 kg.

What communication speeds are supported by the I/O links on the MC-PHAI01?

The Honeywell MC-PHAI01 51403479-150 features dual I/O link support configurable at speeds of 375 Kbaud for PM networks or 750 Kbaud for Series C networks.

View all FAQs →

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 3
Only 5 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
United States

Technical knowledge

Moving TwinCAT 3 Licenses with C9900-L100: Build and Device Checks

Before moving a TwinCAT 3 license with a Beckhoff C9900-L100, verify the TwinCAT build, XML device description, exact order code and cabinet limits.

Replacing a Beckhoff EL4032: Wiring and Output Checks

A field checklist for replacing a Beckhoff EL4032, covering the ±10 V load, terminal map, power contacts, EtherCAT state, and watchdog behavior.

Replacing Yokogawa AAI835: Wiring and Barrier Checks Before Swap

Before replacing a Yokogawa AAI835, verify the 4-in/4-out channel map, power-loss loop behavior, barrier type, output load, cable, and redundancy.

ABB PM891K01 Replacement: Check Redundancy Before Ordering

ABB PM891K01 article 3BSE053241R1 is the non-redundant AC 800M processor kit. Use this field checklist before replacement.

ABB TP853 Replacement Checks for CI853/CI855/CI857/CI861

Replacement checks for ABB TP853 3BSE018126R1: identify the installed CI853, CI855, CI857, or CI861 interface, record wiring, and verify communication after installation.

5069-L330ERMS2 Startup Checks: RTBs, I/O, and Motion Limits

Engineering checks for the Allen-Bradley 5069-L330ERMS2: controller capacity, separate RTB kits, local I/O limits, network-node limits, and motion-axis count.