Designed for high-speed and high-precision data acquisition within industrial automation systems, the Omron NX-AD2608 is a high-performance analog input module featuring 2 differential voltage input channels. Operating within the Sysmac platform, this module converts external analog voltage signals ranging from -10 V to +10 V into high-resolution digital values. With a conversion rate of 10 microseconds per point and a high resolution of 1/30000, it is engineered for applications demanding tight process control and rapid response times.

The Omron NX-AD2608 supports switching between synchronous I/O refreshing and Free-Run refreshing, allowing precise synchronization with the controller CPU or communications coupler unit. The module features a compact, space-saving design with a width of just 12 mm, and integrates a screwless clamping terminal block for fast, reliable wiring in high-vibration environments.

Features

  • Two independent differential voltage input channels with a range of -10 to +10 V.
  • Exceptional conversion speed of 10 us per point for high-speed automation loop responsiveness.
  • High measurement resolution of 1/30000 for precise feedback.
  • Flexible I/O refreshing methods: Switching synchronous I/O refreshing and Free-Run refreshing.
  • Integrated screwless clamping terminal block (8 terminals) for simplified wiring and maintenance.
  • Robust isolation via transformer (power) and digital isolator (signal) between inputs and the NX bus.
  • Status indication via a dedicated TS indicator on the front panel.

Applications

  • High-speed motion control and servo system feedback loops.
  • Factory automation and packaging machinery.
  • Precision temperature, pressure, or flow monitoring systems.
  • Data logging and process monitoring in manufacturing lines.

Technical Specifications

Parameter Specification
Manufacturer Omron
Part Number / Model NX-AD2608
Product Type Analog Input Unit (Voltage)
Number of Points 2 inputs
Input Range -10 to +10 V
Input Method Differential input
Resolution 1/30000
Conversion Time 10 us per point
Input Conversion Range -5% to 105% (full scale)
Absolute Maximum Rating +/-15 V
Input Impedance 1 MOhm min.
Overall Accuracy at 25 degC +/-0.1% (full scale)
Overall Accuracy at 0 to 55 degC +/-0.2% (full scale)
I/O Refreshing Method Switching synchronous I/O refreshing / Free-Run refreshing
Isolation Method Between input and NX bus: Transformer (Power), Digital isolator (Signal). No isolation between inputs.
Insulation Resistance 20 MOhm min. between isolated circuits (at 100 VDC)
Dielectric Strength 510 VAC between isolated circuits for 1 minute (leakage current 5 mA max.)
I/O Power Supply Method No supply
NX Unit Power Consumption Connected to CPU/Communication Control Unit: 1.35 W max.
Connected to Communications Coupler Unit: 1.05 W max.
Dimensions (W x H x D) 12 mm x 100 mm x 71 mm
Weight 0.07 kg

Installation Guidelines

  • Mounting: Mount the unit onto a standard 35 mm DIN rail. Ensure the unit clicks securely into place alongside adjacent NX-series I/O modules.
  • Wiring: Use solid wires or stranded wires with ferrules. Insert the wire directly into the screwless clamping terminal block without the use of tools. To remove, press the release button with a flat-head screwdriver.
  • Noise Mitigation: Utilize shielded twisted-pair cables for analog input lines. Keep signal wiring separated from high-voltage power lines and motor drive cables to prevent electromagnetic interference.
  • Grounding: Ensure the functional ground terminal on the DIN rail is properly grounded according to local industrial electrical codes.

FAQ

What is the input range of the Omron NX-AD2608 module?

The Omron NX-AD2608 supports a differential voltage input range of -10 V to +10 V.

What is the conversion speed and resolution of the NX-AD2608?

The module features a high-speed conversion rate of 10 microseconds per point and a resolution of 1/30000.

Is there electrical isolation between the inputs on this unit?

No, there is no isolation between the individual input channels. However, there is isolation (via transformer for power and digital isolator for signals) between the inputs and the NX bus.

What connection terminal type is used on the NX-AD2608?

It features an 8-terminal screwless clamping terminal block for fast and reliable wiring.

Does the NX-AD2608 require an external I/O power supply?

No, the module does not require or consume power from an external I/O power supply terminal; it is powered via the NX bus.

View all FAQs →

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 4 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Japan

Technical knowledge

IC693CPU360 vs IC693CPU364: Ethernet and Power Budget

Compare the IC693CPU360 and IC693CPU364 by Ethernet interface, +5 VDC load, memory, rack limits, and replacement checks.

1756-OF4 Output Wrong? Check Mode, RTB, and Scaling First

A field-first diagnostic sequence for 1756-OF4 analog output problems: channel mode, removable terminal block, scaling, and controlled electrical checks.

1746-OA8 vs 1746-OA16: Output Count and Current Limits

A direct comparison of 1746-OA8 and 1746-OA16 output count, common grouping, backplane current and temperature-derated load limits.

Replacing a 1761-NET-DNI: Capture These Settings First

A field checklist for recording the 1761-NET-DNI hardware series, firmware, EDS file, DF1 settings, DeviceNet address and messaging configuration before replacement.

EL3062 vs EL3062-0030: The Input Range Changes

The EL3062 is a 0–10 V EtherCAT terminal. The EL3062-0030 is a 0–30 V variant. This checklist covers identification, scaling and commissioning.

Replacing a 1769-OW8: Checks Before Moving Relay Loads

A field checklist for replacing Allen-Bradley 1769-OW8 relay output modules without losing load-group, wiring, and commissioning details.