Description

The 7ML1201-1FE00 is a SITRANS Probe ultrasonic level transmitter designed for continuous, non-contact level monitoring of liquids and slurries. This unit provides a measurement range of up to 5 meters (16.4 ft) and is equipped with a 3-wire relay output for seamless integration into industrial control systems. Engineered for durability, the transmitter features a PVDF copolymer transducer and process connection, ensuring compatibility with a variety of process fluids.

Features

  • Technology: Ultrasonic non-contact level measurement.
  • Range: Up to 5 meters (16.4 ft).
  • Output: 3-wire relay output configuration.
  • Construction: PVDF copolymer transducer and process connection.
  • Process Connection: R 2" (BSPT), EN 10226.
  • Power Requirement: 24 V DC operation.
  • Application: Suitable for liquids and slurries.

Applications

  • Water and wastewater storage tanks.
  • Chemical storage and processing vessels.
  • Slurry level monitoring in mining or industrial processes.
  • Liquid level control in confined industrial containers.

Technical Specifications

Feature Specification
Manufacturer Siemens
Range SITRANS
Model 7ML1201-1FE00
Measurement Range 5 meters (16.40 ft)
Process Connection R 2" (BSPT), EN 10226
Transducer Material PVDF copolymer
Output Type 3-wire relay
Power Supply 24 V DC
Weight 1.60 kg
Dimensions 20.00 cm x 31.00 cm x 95.00 cm
Origin Siemens

Installation Guidelines

  • Mounting: Mount the unit in a vertical position above the medium to be measured to ensure accurate ultrasonic echo returns.
  • Obstructions: Ensure the sensor face has a clear, unobstructed line-of-sight to the surface of the medium, avoiding agitators, pipes, or tank walls within the beam path.
  • Environmental Conditions: While the unit is robust, avoid mounting in locations subject to extreme vacuum or excessive foam, as these can interfere with ultrasonic wave propagation.
  • Wiring: Utilize shielded cabling to minimize electrical interference and ensure the 24 V DC power supply is stable and properly grounded per industrial standards.
  • Maintenance: Periodically clean the transducer face to prevent buildup of material that may cause measurement drift or loss of signal.

FAQ

What is the measuring range of the 7ML1201-1FE00?

The device has a continuous measurement range of 5 meters (16.40 ft).

Is this transmitter suitable for liquids?

Yes, it is designed specifically for non-contact, continuous level monitoring of both liquids and slurries.

What is the recommended replacement for this product?

The manufacturer suggests considering the SITRANS Probe LU240 (7ML51) series as a replacement.

What power supply is required for this unit?

The transmitter operates on a 24 V DC power supply.

View all FAQs →

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 3 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
White
Country of origin
Germany

Technical knowledge

IC693CPU360 vs IC693CPU364: Ethernet and Power Budget

Compare the IC693CPU360 and IC693CPU364 by Ethernet interface, +5 VDC load, memory, rack limits, and replacement checks.

1756-OF4 Output Wrong? Check Mode, RTB, and Scaling First

A field-first diagnostic sequence for 1756-OF4 analog output problems: channel mode, removable terminal block, scaling, and controlled electrical checks.

1746-OA8 vs 1746-OA16: Output Count and Current Limits

A direct comparison of 1746-OA8 and 1746-OA16 output count, common grouping, backplane current and temperature-derated load limits.

Replacing a 1761-NET-DNI: Capture These Settings First

A field checklist for recording the 1761-NET-DNI hardware series, firmware, EDS file, DF1 settings, DeviceNet address and messaging configuration before replacement.

EL3062 vs EL3062-0030: The Input Range Changes

The EL3062 is a 0–10 V EtherCAT terminal. The EL3062-0030 is a 0–30 V variant. This checklist covers identification, scaling and commissioning.

Replacing a 1769-OW8: Checks Before Moving Relay Loads

A field checklist for replacing Allen-Bradley 1769-OW8 relay output modules without losing load-group, wiring, and commissioning details.