Optimized for space-conscious machine-level monitoring, the Mitsubishi Electric GT1150-QBBD-C is a high-performance operator terminal belonging to the specialized GT11 sub-series of the GOT1000 platform. This hardware features a 5.7-inch STN blue-mode monochrome graphical display, engineered to deliver legible diagnostic feedback and interface layouts in challenging industrial environments. Equipped with an onboard 3 MB flash memory system, the unit handles complex screen layouts, alarm histories, and multi-language character sets. Physical communication interfaces include high-speed RS-232, RS-422/485 serial ports, and a dedicated USB connection, enabling robust connectivity directly to MELSEC series controllers or modern manufacturing networks.

Features

  • High-contrast 5.7-inch STN monochrome liquid crystal display with a resolution of 320 x 240 pixels.
  • Integrated 3 MB internal flash memory for efficient storage of project screens and system variables.
  • Multiple built-in ports featuring independent RS-232 and RS-422/485 channels to facilitate multi-device communication.
  • Front-accessible USB interface for direct system updates, programming, and OS restoration.
  • Integrated CompactFlash card slot supporting localized logging data and parameter backups.

Applications

  • Machine-level operational control in packaging and material handling lines.
  • Stand-alone assembly cells and custom manufacturing workstations.
  • Pumping stations, environmental monitoring, and localized HVAC control cabinets.

Technical Specifications

Parameter Specification
Manufacturer Mitsubishi Electric
Model Reference GT1150-QBBD-C
Series Name GOT1000 (GT11 Platform)
Display Unit STN Monochrome (Blue/White) LCD
Screen Size 5.7 Inches
Display Resolution 320 x 240 Pixels
Supply Voltage 24 V DC (+10%, -15%)
User Memory Capacity 3 MB Built-in Flash
Backlight Type Cold cathode fluorescent tube (Replaceable)
External Interfaces RS-232, RS-422/485, USB (Mini-B)
Memory Extension Slot CompactFlash (CF) Card Slot (Max 2 GB)
Protection Rating IP67f (Front section when panel mounted correctly)
Operating Temperature 0 to 50 degC
Shipping Weight (Calculated) 1.45 kg
Package Dimensions (Calculated) 230 mm x 195 mm x 95 mm

Connections and Interfaces

Connector / Port Interface Specification Functional Use
RS-422/485 D-Sub 9-pin Female Primary PLC connection channel (MELSEC or major third-party protocols)
RS-232 D-Sub 9-pin Male Peripheral devices (scanners, printers) or serial PC upload/download
USB Device Mini-B Port High-speed screen design transfer, software communication, and OS updates
Power Terminal Screw Terminal Block 24 V DC power supply input with physical protective ground point

Alternative Models & Compatibility

The GT1150-QBBD-C variant features a conformal protective coating designed for harsh operating environments, distinguishing it from standard, non-coated GT1150-QBBD baseline models. When upgrading to this unit from legacy GOT900 series terminals (such as the F940GOT or GT10 series), screen databases can be seamlessly converted utilizing the migration wizard within GT Designer3. Ensure all communications drivers are updated to support the GT11 system architecture during project migration.

Application Pitfalls & Engineering Notes

As an STN monochrome blue LCD, the screen contrast of this unit is inherently susceptible to temperature shifts. In high-temperature electrical panels, the screen's baseline contrast may drop, leading to ghosting or low visibility. Users should utilize the built-in system utility screen to modify contrast registers or set up automatic contrast adjustments based on temperature. Ensure the surrounding panel cabinet retains a positive air draft if continuous exposure to temperatures close to 50 degC is expected.

Commissioning & Wiring Tips

To avoid communications dropouts or damage to the transceiver components, never route the RS-422/485 serial communication cables adjacent to 480 V high-current motor cables or variable frequency drive (VFD) output wires. Always attach a physical grounding strap to the grounding terminal of the terminal block to divert electromagnetic interference. When accessing the CF card slot, ensure the interface is unmounted or the device is powered off before ejecting the media card to avoid project data corruption.

Installation Guidelines

CRITICAL WARNING: RISK OF ELECTROCUTION AND EQUIPMENT CRASH

Ensure all primary AC and subsidiary DC power sources feeding the target enclosure are fully locked out and tagged out prior to making physical cuts or performing wiring on the GT1150-QBBD-C. Use a calibrated multimeter to verify that the power lines are completely dead and that there are no residual energy pathways.

1

Verify the panel cutout meets the mandatory physical mounting dimensions for standard 5.7-inch GOT1000 panels.

2

Ensure the high-performance waterproof packing gasket is positioned flat, secure, and clear of debris inside the front bezel track of the device.

3

Insert the terminal into the panel cutout and tighten the four mounting screws systematically to the OEM-specified torque to avoid cracking the case.

4

Attach the dedicated 24 V DC supply leads to the screw terminals. Turn on power, enter the terminal configuration menu, and verify the physical system connection parameters match your controller.

Loading product navigation…

What is the primary input voltage requirement for the GT1150-QBBD-C?

This HMI terminal operates on a standard 24 V DC input power supply (+10%, -15% allowable range).

Which software is used to program or update this GOT1000 series terminal?

The screen designs and system settings are programmed using Mitsubishi Electric's GT Designer2 or GT Designer3 software.

What does the -C suffix at the end of the model number represent?

The -C suffix typically designates conformally coated internal PCB components, providing enhanced protection against humidity and airborne contaminants.

Can I save real-time data logs and system alarms to an external card?

Yes, the device contains an integrated CompactFlash (CF) card slot that supports external storage expansion up to 2 GB for logging data and parameters.

Envio Expresso Global

  • Entrega Padrão: 4-6 dias úteis via DHL, FedEx e UPS.
  • Despacho Expresso: Envio no mesmo dia para pedidos em estoque realizados antes das 14:00 (GMT+8).
  • Cobertura Mundial: Atendendo mais de 150 países, incluindo entrega rápida para Arábia Saudita e Emirados Árabes Unidos.

Devoluções e Garantia

  • Garantia de 30 Dias: Devoluções aceitas para produtos em estoque na embalagem original, lacrada de fábrica.
  • Garantia de 12 Meses: Cada componente industrial é coberto pela nossa garantia técnica profissional.

Os pedidos são processados e entregues de segunda a sexta-feira (exceto feriados).


Para elegibilidade completa, taxas de reposição e detalhes de devolução internacional, por favor, consulte nosso oficial Política de Reembolso e Devolução .

TECHNICAL SPECIFICATIONS

Country of origin
Estados Unidos

Produtos Visualizados Recentemente

Conhecimento técnico

Atuadores Elétricos Projetados para Substituir Sistemas Hidráulicos: Um Guia Prático de Automação Industrial

Este artigo explica como os atuadores elétricos integrados, como a série e-Actuator da SMC, estão transformando o controle de movimento industrial ao substituir os sistemas pneumáticos e hidráulicos...

Operações Matemáticas Usando OpenPLC para Aplicações de Automação Industrial

Este artigo explica como os sistemas PLC realizam operações matemáticas básicas, como adição, subtração, multiplicação, divisão, módulo e exponenciação dentro da automação industrial. Ele mostra como...

Lógica Booleana Avançada com Programação FBD em CLP: Aplicações Industriais Práticas Além da Lógica Básica

O artigo explica várias funções avançadas de lógica Booleana usadas na programação de CLPs além das operações básicas AND, OR e NOT. Ele aborda como ferramentas como tabelas verdade, multiplexadores,...

Lógica Booleana na Programação de CLP: Entendendo Portas Lógicas FBD

A lógica booleana é a base de todo programa PLC. Desde controles simples de máquinas até sistemas complexos de automação industrial, as portas lógicas determinam como os controladores respondem a...

Guia Completo sobre Firewalls Industriais e Segmentação de Redes OT

Firewalls industriais desempenham um papel crucial na cibersegurança OT, protegendo redes PLC, DCS e SCADA por meio de segmentação, controle de entrada/saída e integração IDS/IPS alinhada aos...

Guia de Garras Robóticas: Do Manuseio Delicado à Automação Pesada

As garras robóticas modernas estão evoluindo além das tradicionais mandíbulas mecânicas. De sistemas adesivos inspirados em lagartos-gecko e garras macias de grau alimentício a ferramentas de armazém...