1 จาก 3

MTL 8502-BI-DP Eaton MTL 8500 Series PROFIBUS-DP Bus Interface Module

MTL 8502-BI-DP Eaton MTL 8500 Series PROFIBUS-DP Bus Interface Module

Only 2 item(s) left in stock
  • Manufacturer: EATON

  • Product No.: 8502-BI-DP

  • Country of origin:สหราชอาณาจักร

  • Product Type: Bus Interface Module

  • Barcode: 8537101190

  • Payment: T/T, Western Union

  • Weight: 450g

  • Dimensions: 12.2cm x 10.7cm x 3cm

  • Shipping port: Xiamen

  • Warranty: 12 months

ปริมาณ
ดูรายละเอียดทั้งหมด

Product Overview

The MTL 8502-BI-DP (MTL8502BIDP) is a high-performance Bus Interface (BI) module designed to bridge the gap between Eaton’s MTL 8500 series I/O system and a PROFIBUS-DP master controller. This module acts as the "brain" of the I/O rack, managing communication between the field-side I/O modules and the higher-level DCS or PLC. It is specifically engineered for critical process automation applications in sectors such as power generation, oil and gas, and pharmaceutical manufacturing. By providing a reliable, high-speed gateway, the MTL 8502-BI-DP ensures that digitized field data is accurately reported to the control system, facilitating real-time monitoring and deterministic control of complex industrial processes.

Technical Configuration (Deep Dive)

The MTL 8502-BI-DP is built on a high-speed communication architecture that prioritizes data integrity and network resilience.

  • PROFIBUS-DP Protocol Support: Full compliance with the PROFIBUS-DP standard, supporting baud rates from 9.6 kbps up to 12 Mbps. This allows the module to integrate seamlessly into existing industrial networks regardless of the master controller brand.

  • I/O Scanning Logic: The module manages the scanning of up to 32 I/O modules on a single backplane. It collects analog and digital data, performs internal diagnostics, and packages the information into PROFIBUS telegrams.

  • Redundancy Capabilities: When installed on a redundant backplane, two MTL 8502-BI-DP modules can operate in a primary/secondary configuration. If the primary module or its network link fails, the secondary module takes over communication instantly, preventing system-wide downtime.

  • Galvanic Isolation: Features 500 V AC isolation between the PROFIBUS network and the internal I/O bus, protecting the backplane and field modules from potential network-side surges and common-mode noise.

Technical Specifications

Feature Specification
Model MTL 8502-BI-DP
Brand Eaton MTL
Origin United Kingdom
Interface Protocol PROFIBUS-DP
Transmission Rate 9.6 kbps to 12 Mbps (Auto-sensing)
Address Range 1 to 125 (Hardware or Software configurable)
Supply Voltage 18 - 32 VDC (via backplane)
Operating Temp -40 to 70 deg C
Relative Humidity 5 to 95 percent RH
Weight 0.45 kg

Technical FAQs

Q1: How is the PROFIBUS address set on the MTL 8502-BI-DP?

A1: The module address can be set either via hardware rotary switches located on the front of the unit or through software configuration using the GSD file in the PROFIBUS master’s configuration tool.

Q2: Does the module support hot-swapping?

A2: Yes, the MTL 8502-BI-DP is designed for live insertion and removal. In a redundant setup, you can replace a faulty interface module without disrupting the communication between the I/O rack and the DCS.

Q3: What diagnostic information is available via the PROFIBUS network?

A3: The module provides comprehensive status data, including backplane power health, I/O module presence/failure, and network communication errors, allowing for granular troubleshooting from the control room.


Engineering & Installation Guide

  • Network Termination: Ensure that the PROFIBUS-DP line is correctly terminated at both ends of the segment. If the MTL 8502-BI-DP is the last device on the network, use a PROFIBUS connector with an integrated, active termination switch set to "ON."

  • GSD File Integration: Before commissioning, import the correct GSD (General Station Description) file into your PLC/DCS hardware configuration. This file contains the critical timing and parameter information required for the master to recognize the MTL 8500 system.

  • Shielding Practices: Use only high-quality, shielded PROFIBUS (purple) cable. The shield must be continuously connected through all connectors and grounded at the point of entry into the control cabinet to minimize RFI/EMI interference.

Engineering Advantages

The MTL 8502-BI-DP stands out for its extreme reliability in high-vibration and high-temperature environments. Its ability to manage large I/O counts through a single PROFIBUS node significantly reduces the cost of network infrastructure. Furthermore, the module's transparency to advanced diagnostics enables predictive maintenance strategies, helping plant operators identify deteriorating field conditions before they lead to hardware failure.

การจัดส่งด่วนทั่วโลก

  • การจัดส่งมาตรฐาน: 4-6 วันทำการ ผ่าน DHL, FedEx และ UPS
  • จัดส่งด่วน: จัดส่งในวันเดียวกันสำหรับคำสั่งซื้อที่มีในสต็อกและสั่งก่อนเวลา 14:00 น. (GMT+8)
  • ครอบคลุมทั่วโลก: ให้บริการมากกว่า 150 ประเทศ รวมถึงการจัดส่งด่วนไปยังซาอุดีอาระเบียและสหรัฐอาหรับเอมิเรตส์

การคืนสินค้าและการรับประกัน

  • การรับประกัน 30 วัน: รับคืนสินค้าที่มีในสต็อกในบรรจุภัณฑ์เดิมที่ปิดผนึกจากโรงงาน
  • การรับประกัน 12 เดือน: อะไหล่อุตสาหกรรมทุกชิ้นได้รับการรับประกันทางเทคนิคจากผู้เชี่ยวชาญของเรา

คำสั่งซื้อจะถูกดำเนินการและจัดส่งในวันจันทร์ถึงวันศุกร์ (ไม่รวมวันหยุดราชการ)


สำหรับคุณสมบัติครบถ้วน ค่าธรรมเนียมการเติมสินค้าใหม่ และรายละเอียดการคืนสินค้าระหว่างประเทศ กรุณาดูที่เว็บไซต์อย่างเป็นทางการของเรา นโยบายการคืนเงินและการคืนสินค้า .

TECHNICAL SPECIFICATIONS

Color pattern
สีดำ สีขาวอมเทา
Country of origin
สหราชอาณาจักร
Power source
ไฟฟ้ากระแสตรง

Customer Reviews

Be the first to write a review
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)

สินค้าที่ดูล่าสุด

ความรู้ทางเทคนิค

ตัวกระตุ้นไฟฟ้าที่ออกแบบมาเพื่อทดแทนระบบพลังงานของเหลว: คู่มือการทำงานอัตโนมัติในอุตสาหกรรมอย่างเป็นประโยชน์

บทความนี้อธิบายถึงวิธีที่แอคชูเอเตอร์ไฟฟ้าแบบบูรณาการ เช่น ซีรีส์ e-Actuator ของ SMC กำลังเปลี่ยนแปลงการควบคุมการเคลื่อนที่ในอุตสาหกรรมโดยการทดแทนระบบนิวเมติกและไฮดรอลิกแบบดั้งเดิม...

การดำเนินการทางคณิตศาสตร์โดยใช้ OpenPLC สำหรับแอปพลิเคชันระบบอัตโนมัติในอุตสาหกรรม

บทความนี้อธิบายวิธีที่ระบบ PLC ดำเนินการคำนวณทางคณิตศาสตร์พื้นฐาน เช่น การบวก การลบ การคูณ การหาร โมดูลัส และการยกกำลังในระบบอัตโนมัติอุตสาหกรรม...

ตรรกะบูลีนขั้นสูงด้วยการเขียนโปรแกรม FBD PLC: การประยุกต์ใช้งานในอุตสาหกรรมที่เกินกว่าตรรกะพื้นฐาน

บทความนี้อธิบายฟังก์ชันตรรกะบูลีนขั้นสูงหลายอย่างที่ใช้ในการเขียนโปรแกรม PLC นอกเหนือจากการดำเนินการพื้นฐานอย่าง AND, OR และ NOT โดยครอบคลุมถึงการใช้เครื่องมือต่างๆ เช่น ตารางความจริง มัลติเพล็กเซอร์...

ตรรกะบูลีนในการเขียนโปรแกรม PLC: ทำความเข้าใจเกตตรรกะ FBD

ตรรกะบูลีนเป็นพื้นฐานของโปรแกรม PLC ทุกโปรแกรม ตั้งแต่การควบคุมเครื่องจักรง่ายๆ ไปจนถึงระบบอัตโนมัติในอุตสาหกรรมที่ซับซ้อน...

คู่มือเชิงลึกเกี่ยวกับไฟร์วอลล์อุตสาหกรรมและการแบ่งส่วนเครือข่าย OT

ไฟร์วอลล์อุตสาหกรรมมีบทบาทสำคัญในความปลอดภัยไซเบอร์ของ OT โดยปกป้องเครือข่าย PLC, DCS และ SCADA ผ่านการแบ่งส่วน การควบคุมการเข้า/ออก และการผสานรวม IDS/IPS ที่สอดคล้องกับหลักการ IEC 62443

คู่มือการใช้งานกริปเปอร์หุ่นยนต์: ตั้งแต่การจับที่ละเอียดอ่อนจนถึงระบบอัตโนมัติสำหรับงานหนัก

กริปเปอร์หุ่นยนต์สมัยใหม่กำลังพัฒนาก้าวข้ามกรามกลไกแบบดั้งเดิม ตั้งแต่ระบบกาวที่ได้แรงบันดาลใจจากจิ้งจกและกริปเปอร์นุ่มที่ใช้ในอาหาร ไปจนถึงเครื่องมือคลังสินค้าที่ขับเคลื่อนด้วย AI...