1 از 1

ProSoft MV156-MCMR Modbus Master/Slave Communication Module

ProSoft MV156-MCMR Modbus Master/Slave Communication Module

فقط 10 قلم(های) کالا در انبار باقی مانده است
  • تولیدکننده: ProSoft

  • شماره محصول: MV156-MCMR

  • کشور سازنده:ایالات متحده آمریکا

  • نوع محصول: Modbus Communication Modules

  • پرداخت: حواله بانکی (T/T)، وسترن یونیون

  • وزن: 1500g

  • بندر حمل و نقل: شیامن

  • گارانتی: ۱۲ ماه

تعداد
مشاهده جزئیات کامل

Description

Interfacing directly with the system backplane, the ProSoft MV156-MCMR operates as a highly integrated Modbus Master/Slave communication interface module. This module enables serial communication with various industrial control devices, functioning as either a Master or a Slave across independent serial ports. Designed to optimize bandwidth in distributed control networks, the ProSoft MV156-MCMR implements a reduced data block transfer structure, which is ideal for remote I/O configurations or networks with constrained throughput. The module natively manages data transfers, floating-point math scaling, and error checking directly within its onboard processing unit, minimizing processing overhead on the host controller.

Key Features

  • Dual Independent Serial Ports: Each port is configurable as a Modbus Master or Slave, supporting RS-232, RS-422, or RS-485 physical layer interfaces.
  • Reduced Block Transfer: Optimized for remote racks or lower-bandwidth communication links by using smaller block transfer configurations.
  • Comprehensive Protocol Modes: Full compatibility with Modbus RTU (binary with CRC-16) and Modbus ASCII (with LRC error checking) transmission modes.
  • Specialized Floating-Point Integration: Configurable support for specialized floating-point data parsing, including Enron, Daniel, and standard IEEE formats.
  • Real-Time Diagnostics: Dynamic visual feedback via front-facing LEDs tracking backplane data transfer, serial port activity, and module health.

Typical Applications

  • SCADA and Human-Machine Interface (HMI) coordination across distant terminal sites.
  • Integration of flow computers, power monitors, and gas chromatographs in petro-chemical installations.
  • Distributed Variable Frequency Drive (VFD) and motor protection relay tracking in MCC panels.
  • Building automation and sub-metering infrastructure aggregation.

Technical Specifications

Specification Parameter Value / Details
Manufacturer ProSoft Technology
Model Number MV156-MCMR
Backplane Current Draw 800 mA at 5 Vdc, 3 mA at 24 Vdc
Operating Temperature 0 to 60 degC (32 to 140 degF)
Storage Temperature -40 to 85 degC (-40 to 185 degF)
Relative Humidity 5% to 95% (non-condensing)
Vibrational Rating 5 g from 10 Hz to 150 Hz
Operational Shock 30 g operational, 50 g non-operational
Supported Baud Rates 110 to 115,200 baud
Data Bits 7 or 8 bits
Parity Selection None, Odd, Even
Stop Bits 1 or 2
RTS Timing Delays 0 to 65535 milliseconds
Shipping Weight (Calculated) 1.5 kg (3.3 lbs)

Alternative Models & Compatibility

The MV156-MCMR is functionally optimized to replace standard high-block-size modules in architectures where backplane memory bandwidth is highly constrained. While the traditional MVI56-MCM uses larger transfer blocks, the MCMR variant relies on a reduced, adjustable block design to fit tight network frames. Ensure that the configuration blocks mapped in your ladder logic block layout are adjusted to match the MCMR block sizes to prevent processing faults during system retrofits.

Application Pitfalls & Engineering Notes

When operating at high baud rates (e.g., 115,200 baud) or under heavy packet loading, thermal dissipation within enclosed control panels must be addressed. Ensure adjacent slots provide sufficient passive convection. Additionally, when using Enron/Daniel floating-point modes, verification of the byte-swapping order is necessary to prevent data truncation or alignment mismatches between the controller memory structure and the external field device.

Commissioning & Wiring Tips

For RS-485 daisy-chained communication loops, a termination resistor (120-ohm) must be connected across the TX/RX+ and TX/RX- terminals of the physical end-of-line units. To mitigate electromagnetic interference and shield noise issues, the communication cable shield must be grounded at exactly one physical location in the network loop—preferably at the controller rack termination point.

Installation Guidelines

CRITICAL WARNING:

Isolate and completely shut down all electrical power to the system chassis before inserting, adjusting, or extracting the communication module. Performing hot-swapping or handling live components risks severe physical backplane damage, electrical shock, and communication failures on the remaining active nodes.

1
Turn off all power feeding the system chassis and associated communication field networks.
2
Align the module carefully with the slot guide rails, keeping it perpendicular to the chassis backplane.
3
Firmly slide the module forward until it seats completely into the backplane connectors, then tighten the retaining screws to lock it into position.
4
Connect the serial terminal blocks, power on the chassis, and check the front-panel status LEDs for normal initialization.
Loading product navigation…

What is the primary difference between the MV156-MCMR and the MVI56-MCM?

The MCMR variant utilizes a reduced data block transfer mechanism. This optimization minimizes memory footprint on the backplane, making it ideal for communication modules mounted in remote I/O chassis over ControlNet or Ethernet networks.

Does the MV156-MCMR module support Enron and Daniel floating-point formats?

Yes, it fully supports specialized floating-point configurations, allowing easy data movement and byte-swapping configuration for compatibility with Enron and Daniel flow computers.

Can I configure both serial ports on the module to run different protocols?

Yes, each port acts independently. You can configure one port as a Modbus Master running RTU mode, and the second port as a Modbus Slave running ASCII mode, each with distinct baud rate and parity settings.

What is the typical backplane power draw for the MV156-MCMR?

The module draws 800 mA at 5 Vdc and 3 mA at 24 Vdc directly from the backplane power supply. Ensure your power supply module has enough headroom.

ارسال سریع جهانی

  • تحویل استاندارد: ۴-۶ روز کاری از طریق DHL، FedEx و UPS.
  • ارسال فوری: ارسال همان روز برای سفارش‌های موجود در انبار که قبل از ساعت ۲:۰۰ بعدازظهر (GMT+8) ثبت شده‌اند.
  • پوشش جهانی: خدمات به بیش از ۱۵۰ کشور، شامل تحویل سریع به عربستان سعودی و امارات.

بازگشت کالا و گارانتی

  • ضمانت ۳۰ روزه: بازگشت کالا برای محصولات موجود در انبار با بسته‌بندی اصلی و مهر کارخانه پذیرفته می‌شود.
  • گارانتی ۱۲ ماهه: هر قطعه صنعتی با گارانتی فنی حرفه‌ای ما پشتیبانی می‌شود.

سفارش‌ها از دوشنبه تا جمعه (به جز تعطیلات رسمی) پردازش و تحویل داده می‌شوند.


برای شرایط کامل واجد شرایط بودن، هزینه‌های بازگردانی و جزئیات بازگشت بین‌المللی، لطفاً صفحه رسمی ما را مشاهده کنید سیاست بازپرداخت و بازگشت کالا .

TECHNICAL SPECIFICATIONS

Country of origin
ایالات متحده آمریکا

محصولات مشاهده‌شده اخیر

دانش فنی

منطق بولی پیشرفته با برنامه‌نویسی FBD PLC: کاربردهای عملی صنعتی فراتر از منطق پایه

این مقاله چندین تابع پیشرفته منطق بولی را که در برنامه‌نویسی PLC فراتر از عملیات پایه AND، OR و NOT استفاده می‌شوند، توضیح می‌دهد. همچنین نحوه استفاده از ابزارهایی مانند جداول صحت، مالتی‌پلکسرها،...

منطق بولی در برنامه‌نویسی PLC: درک گیت‌های منطقی FBD

منطق بولی پایه و اساس هر برنامه PLC است. از کنترل‌های ساده ماشین تا سیستم‌های پیچیده اتوماسیون صنعتی، دروازه‌های منطقی تعیین می‌کنند که کنترل‌کننده‌ها چگونه به ورودی‌ها و شرایط عملیاتی متغیر پاسخ...

راهنمای جامع فایروال‌های صنعتی و تقسیم‌بندی شبکه OT

فایروال‌های صنعتی نقش حیاتی در امنیت سایبری OT ایفا می‌کنند و از شبکه‌های PLC، DCS و SCADA از طریق بخش‌بندی، کنترل ورود/خروج و ادغام IDS/IPS مطابق با اصول IEC 62443 محافظت می‌کنند.

راهنمای گیره‌های رباتیک: از جابجایی ظریف تا اتوماسیون سنگین

گیره‌های رباتیک مدرن فراتر از فک‌های مکانیکی سنتی در حال پیشرفت هستند. از سیستم‌های چسبنده الهام‌گرفته از گکوی، گیره‌های نرم با درجه‌بندی غذایی تا ابزارهای انبار مجهز به هوش مصنوعی، فناوری‌های...

بازگشت به گذشته: چگونه موتورهای الکتریکی اولیه معدن‌کاری زیرزمینی را تغییر دادند

از کمپرسورهای جریان مستقیم با نیروی طناب تا واگن‌های معدنی باتری‌دار، عملیات‌های اولیه معدن‌کاری نقطه عطفی در برق‌رسانی صنعتی بودند. این مقاله بررسی می‌کند که چگونه موتورهای الکتریکی پیش از ورود...

Factory I/O: یک ابزار شبیه‌سازی PLC مدرن برای آموزش اتوماسیون صنعتی

Factory I/O آموزش PLC را با ارائه شبیه‌سازی‌های صنعتی سه‌بعدی فراگیر برای دانشجویان، مهندسان و تیم‌های نگهداری متحول می‌کند. این پلتفرم فاصله بین نظریه و عمل واقعی اتوماسیون را پر می‌کند و در عین حال...