Facilitating seamless data communication between EtherNet/IP-enabled control networks and Modbus serial networks, the ProSoft PLX31-EIP-MBS protocol converter operates as a standalone gateway. Designed to link Rockwell Automation PLCs, including ControlLogix and CompactLogix systems, to Modbus RTU/ASCII-compliant devices, this module acts as a bridge for legacy and modern system integration. It allows the integration of sensors, drives, and specialized instrumentation into high-level control architectures without requiring expensive network overhauls.

The gateway is engineered for harsh industrial environments, offering high electrical isolation on both the Ethernet and serial pathways to prevent damage from ground loops. Featuring a compact form factor for DIN rail installation, the gateway delivers reliable data routing with configurable read/write commands, mapping internal registry memory across protocols with minimum transmission latency.

Features

  • Dual-protocol mapping facilitates real-time data exchange between EtherNet/IP master/slave devices and Modbus RTU/ASCII networks.
  • Complete galvanic isolation on serial and Ethernet communication paths shields control equipment from electrical noise and voltage transients.
  • Integrated diagnostic LEDs provide real-time status indication for power, network connectivity, internal errors, and port traffic.
  • Flexible power input tolerances make the module suitable for diverse industrial power distribution standards.
  • Configuration is managed via user-friendly software utilities, allowing memory offset mapping and quick deployment.

Applications

  • Oil and gas production monitoring, connecting Modbus-based flow meters to EtherNet/IP RTU networks.
  • Water and wastewater plant automation for motor control center (MCC) integration.
  • Power generation and substation systems linking protective relays to central SCADA systems.
  • Factory automation environments standardizing fieldbus devices onto unified Ethernet backbones.

Technical Specifications

Manufacturer ProSoft Technology
Part Number / Model PLX31-EIP-MBS
Power Supply Input 24 VDC nominal (10 VDC to 36 VDC allowable)
Current Load 24 VDC nominal @ 300 mA (10 VDC to 36 VDC @ 610 mA maximum)
Operating Temperature -25 degC to 70 degC (-13 degF to 158 degF)
Storage Temperature -40 degC to 80 degC (-40 degF to 176 degF)
Relative Humidity 5% to 95% RH (non-condensing)
Vibration Protection IEC 60068-2-6; 5G @ 10 to 150 Hz
Ethernet Port 1x 10/100 Mbps RJ45 port (half/full duplex)
Ethernet Isolation 1500 Vrms for 60 seconds (per IEC 60950: 1991 section 5.3.2)
Serial Communication Port 1x RS-232/422/485 configurable port
Serial Port Isolation 2500 Vrms port signal isolation per UL 1577 (using RF-based isolation media)
LED Status Indicators Configuration (CFG), Error (ERR), Power (PWR), Hardware Fault (FLT), Network Status (NS), Module Status (MS), Serial RX/TX, Ethernet Link/Activity
Dimensions (H x W x D) 13.67 cm x 5.05 cm x 11.13 cm (approximate)
Shipping Weight 2.0 kg

Connections and Interfaces

Interface / Pin Function Description
RJ45 Port EtherNet/IP network communication and configuration port
Serial Port RS-232, RS-422, or RS-485 connection to Modbus slave or master field devices
V+ Terminal Positive DC Power input (10 to 36 VDC)
V- Terminal Negative DC Power return line
GND Terminal Chassis/Functional Ground reference

Installation Guidelines

  • Ensure the unit is mounted on a standard 35mm DIN rail within a dust-free and temperature-regulated control enclosure.
  • Always use shielded Ethernet (Category 5e or higher) and shielded twisted-pair serial cables to limit electromagnetic interference (EMI).
  • Connect the GND terminal directly to a clean, low-resistance functional earth ground bus bar.
  • Ensure there is adequate ventilation spacing of at least 25mm above and below the module during operation.
Loading product navigation…

What power input does the ProSoft PLX31-EIP-MBS require?

The gateway operates on a nominal 24 VDC power supply, but is compatible with a wider input range of 10 to 36 VDC.

Does the serial port on the PLX31-EIP-MBS feature isolation?

Yes, the serial port provides 2500 Vrms signal isolation utilizing RF modulation technology compliant with UL 1577 standards.

Can this gateway be used in extreme temperature environments?

Yes, the module is rated for an industrial operating temperature range of -25 degC to 70 degC (-13 degF to 158 degF).

Which Modbus protocols are supported by the serial port?

The gateway supports both Modbus RTU and Modbus ASCII protocols on its configurable RS-232/422/485 serial port.

ارسال سریع جهانی

  • تحویل استاندارد: ۴-۶ روز کاری از طریق DHL، FedEx و UPS.
  • ارسال فوری: ارسال همان روز برای سفارش‌های موجود در انبار که قبل از ساعت ۲:۰۰ بعدازظهر (GMT+8) ثبت شده‌اند.
  • پوشش جهانی: خدمات به بیش از ۱۵۰ کشور، شامل تحویل سریع به عربستان سعودی و امارات.

بازگشت کالا و گارانتی

  • ضمانت ۳۰ روزه: بازگشت کالا برای محصولات موجود در انبار با بسته‌بندی اصلی و مهر کارخانه پذیرفته می‌شود.
  • گارانتی ۱۲ ماهه: هر قطعه صنعتی با گارانتی فنی حرفه‌ای ما پشتیبانی می‌شود.

سفارش‌ها از دوشنبه تا جمعه (به جز تعطیلات رسمی) پردازش و تحویل داده می‌شوند.


برای شرایط کامل واجد شرایط بودن، هزینه‌های بازگردانی و جزئیات بازگشت بین‌المللی، لطفاً صفحه رسمی ما را مشاهده کنید سیاست بازپرداخت و بازگشت کالا .

TECHNICAL SPECIFICATIONS

Country of origin
ایالات متحده آمریکا

محصولات مشاهده‌شده اخیر

دانش فنی

منطق بولی پیشرفته با برنامه‌نویسی FBD PLC: کاربردهای عملی صنعتی فراتر از منطق پایه

این مقاله چندین تابع پیشرفته منطق بولی را که در برنامه‌نویسی PLC فراتر از عملیات پایه AND، OR و NOT استفاده می‌شوند، توضیح می‌دهد. همچنین نحوه استفاده از ابزارهایی مانند جداول صحت، مالتی‌پلکسرها،...

منطق بولی در برنامه‌نویسی PLC: درک گیت‌های منطقی FBD

منطق بولی پایه و اساس هر برنامه PLC است. از کنترل‌های ساده ماشین تا سیستم‌های پیچیده اتوماسیون صنعتی، دروازه‌های منطقی تعیین می‌کنند که کنترل‌کننده‌ها چگونه به ورودی‌ها و شرایط عملیاتی متغیر پاسخ...

راهنمای جامع فایروال‌های صنعتی و تقسیم‌بندی شبکه OT

فایروال‌های صنعتی نقش حیاتی در امنیت سایبری OT ایفا می‌کنند و از شبکه‌های PLC، DCS و SCADA از طریق بخش‌بندی، کنترل ورود/خروج و ادغام IDS/IPS مطابق با اصول IEC 62443 محافظت می‌کنند.

راهنمای گیره‌های رباتیک: از جابجایی ظریف تا اتوماسیون سنگین

گیره‌های رباتیک مدرن فراتر از فک‌های مکانیکی سنتی در حال پیشرفت هستند. از سیستم‌های چسبنده الهام‌گرفته از گکوی، گیره‌های نرم با درجه‌بندی غذایی تا ابزارهای انبار مجهز به هوش مصنوعی، فناوری‌های...

بازگشت به گذشته: چگونه موتورهای الکتریکی اولیه معدن‌کاری زیرزمینی را تغییر دادند

از کمپرسورهای جریان مستقیم با نیروی طناب تا واگن‌های معدنی باتری‌دار، عملیات‌های اولیه معدن‌کاری نقطه عطفی در برق‌رسانی صنعتی بودند. این مقاله بررسی می‌کند که چگونه موتورهای الکتریکی پیش از ورود...

Factory I/O: یک ابزار شبیه‌سازی PLC مدرن برای آموزش اتوماسیون صنعتی

Factory I/O آموزش PLC را با ارائه شبیه‌سازی‌های صنعتی سه‌بعدی فراگیر برای دانشجویان، مهندسان و تیم‌های نگهداری متحول می‌کند. این پلتفرم فاصله بین نظریه و عمل واقعی اتوماسیون را پر می‌کند و در عین حال...