1 of 1

BK2000 | BECKHOFF | Coupleur de bus Lightbus

BK2000 | BECKHOFF | Coupleur de bus Lightbus

Il ne reste que 10 article(s) en stock
  • Fabricant : BECKHOFF

  • N° de produit : BK2000

  • Pays d'origine :Allemagne

  • Type de produit : Accoupleur de bus Lightbus

  • Paiement : Virement bancaire, Western Union

  • Poids : 150g

  • Port d'expédition : Xiamen

  • Garantie : 12 mois

Quantité
Voir les détails complets

Description

Engineered for deterministic communication in high-interference environments, the BECKHOFF BK2000 Lightbus Bus Coupler serves as the decentralized interface between the fiber-optic Lightbus system and modular Beckhoff Bus Terminals. This unit automatically configures and maps the digital, analog, and specialty process signals from up to 64 connected I/O terminals directly into the control system's memory. By using fiber-optic transmission media, the module ensures complete electrical isolation, high noise immunity, and rapid data exchange rates of 2.5 MBaud. This configuration makes it highly suitable for complex, geographically distributed control architectures where electrical noise and ground loops are common concerns.

Features

  • Integrates a specialized Lightbus fiber-optic interface for high-speed, noise-free industrial communication.
  • Supports the direct connection of up to 64 Beckhoff Bus Terminals to a single node.
  • Provides an internal K-bus output current of up to 1.75 A to power connected I/O terminal logic.
  • Equipped with an integrated configuration interface compatible with the KS2000 software tool.
  • Features integrated, isolated 24 V DC power contacts for reliable peripheral power distribution.
  • Robust IP20-rated housing with a compact DIN-rail mounting profile.

Applications

  • Distributed control networks in high-voltage and power-generation facilities.
  • Automotive assembly lines prone to high electromagnetic welding interference.
  • Water and wastewater treatment facility telemetry.
  • Heavy machinery and packaging systems requiring robust, isolated I/O nodes.

Technical Specifications

Parameter Value
Manufacturer BECKHOFF
Part Number/Model BK2000
Product Type Lightbus Bus Coupler
Communication Protocol Lightbus (fiber-optic)
Baud Rate 2.5 MBaud
Supply Voltage 24 V DC (+/- 10%)
Input Current 105 mA typical, 900 mA maximum
K-bus Output Current 1.75 A maximum
Supply Isolation 500 Veff (K-bus / supply voltage)
Max. Number of Bus Terminals 64
Digital Peripheral Signals 256 inputs and outputs
Analog Peripheral Signals 128 inputs and outputs
Peripheral Process Image 512 input bytes, 512 output bytes
Configuration Port KS2000 configuration interface
Power Contacts Voltage 24 V DC / AC
Power Contacts Current Load 10 A maximum
Max. Voltage Capacity 500 Veff (power contact / supply voltage)
Housing Protection Rating IP20
Operating Temperature 0 degC to +55 degC
Storage Temperature -25 degC to +85 degC
Relative Humidity 95% non-condensing
Vibration / Shock Resistance According to IEC 68-2-6 / IEC 68-2-27
EMC Immunity (Burst / ESD) According to EN 61000-4-4 / EN 61000-4-2
Mounting Orientation Any orientation
Weight Approx. 150 g

Installation Guidelines

  • Mount the coupler onto a standard 35 mm DIN rail (EN 60715) by snapping it into place until secure.
  • Ensure the system is completely de-energized before connecting the 24 V DC control power or peripheral wiring.
  • Observe minimum bending radii for all connected Lightbus fiber-optic cables to avoid signal attenuation or physical damage.
  • Keep the ventilation slots on the top and bottom of the housing clear of obstructions to facilitate proper thermal convection.
  • Verify that the total current draw of all connected Bus Terminals does not exceed the maximum 1.75 A K-bus current limit. Use power feed terminals if necessary.

Compliance and Certifications

  • CE
  • IEC 68-2-6 (Vibration Resistance)
  • IEC 68-2-27 (Shock Resistance)
  • EN 61000-4-4 / EN 61000-4-2 (Electromagnetic Compatibility Standards)
Loading product navigation…

What is the maximum number of I/O terminals that can be connected to the BECKHOFF BK2000?

The BK2000 coupler supports the connection of up to 64 individual Beckhoff Bus Terminals.

What is the maximum current capacity of the K-bus output?

The BK2000 provides a maximum of 1.75 A to the K-bus to power the logic of connected terminals. If your system exceeds this limit, additional power feed terminals must be added.

Does the BK2000 support configuration via software?

Yes, the coupler features an integrated configuration interface that is compatible with Beckhoff's KS2000 software.

What are the environmental limits for operating the BK2000?

The BK2000 is rated for operation in temperatures ranging from 0 degC to +55 degC, with up to 95% non-condensing relative humidity.

Can the BK2000 be mounted in any direction?

Yes, the manufacturer specifies that the coupler can be mounted in any orientation on a standard DIN rail.

Expédition express mondiale

  • Livraison standard : 4 à 6 jours ouvrables via DHL, FedEx et UPS.
  • Expédition express : Expédition le jour même pour les commandes en stock passées avant 14h00 (GMT+8).
  • Couverture mondiale : Service dans plus de 150 pays, avec livraison rapide en Arabie Saoudite et aux Émirats arabes unis.

Retours et garantie

  • Garantie de 30 jours : Retours acceptés pour les produits en stock dans leur emballage d'origine scellé en usine.
  • Garantie de 12 mois : Chaque composant industriel est couvert par notre garantie technique professionnelle.

Les commandes sont traitées et livrées du lundi au vendredi (hors jours fériés).


Pour connaître l'éligibilité complète, les frais de restockage et les détails des retours internationaux, veuillez consulter notre site officiel Politique de remboursement et de retour .

TECHNICAL SPECIFICATIONS

Country of origin
Allemagne

Produits récemment consultés

Connaissances techniques

Actionneurs électriques conçus pour remplacer les systèmes à fluide : un guide pratique d'automatisation industrielle

Cet article explique comment les actionneurs électriques intégrés, tels que la série e-Actuator de SMC, transforment le contrôle du mouvement industriel en remplaçant les systèmes pneumatiques et...

Opérations mathématiques avec OpenPLC pour les applications d'automatisation industrielle

Cet article explique comment les systèmes PLC réalisent des opérations mathématiques de base telles que l'addition, la soustraction, la multiplication, la division, le modulo et l'exponentiation dans...

Logique booléenne avancée avec la programmation FBD PLC : applications industrielles pratiques au-delà de la logique de base

L'article explique plusieurs fonctions avancées de la logique booléenne utilisées en programmation d'automates programmables industriels (API) au-delà des opérations de base ET, OU et NON. Il aborde...

Logique booléenne en programmation PLC : comprendre les portes logiques FBD

La logique booléenne est la base de tout programme PLC. Des commandes machines simples aux systèmes d'automatisation industrielle complexes, les portes logiques déterminent comment les contrôleurs...

Guide approfondi sur les pare-feux industriels et la segmentation des réseaux OT

Les pare-feux industriels jouent un rôle crucial dans la cybersécurité OT, protégeant les réseaux PLC, DCS et SCADA grâce à la segmentation, au contrôle des entrées/sorties et à l’intégration IDS/IPS...

Guide des pinces robotiques : de la manipulation délicate à l'automatisation lourde

Les pinces robotiques modernes évoluent au-delà des mâchoires mécaniques traditionnelles. Des systèmes adhésifs inspirés des geckos aux pinces souples de qualité alimentaire, en passant par des...