1 of 1

CX2550-0179 | BECKHOFF | Extendeur USB Tx pour CX20xx (CP69xx-xxxx-0000

CX2550-0179 | BECKHOFF | Extendeur USB Tx pour CX20xx (CP69xx-xxxx-0000

Il ne reste que 10 article(s) en stock
  • Fabricant : BECKHOFF

  • N° de produit : CX2550-0179

  • Pays d'origine :Allemagne

  • Type de produit : Émetteur USB Extender pour CX20xx (CP69xx-xxxx-0000

  • Paiement : Virement bancaire, Western Union

  • Poids : 500g

  • Dimensions : 24 mm x 99 mm x 54.5 mm

  • Port d'expédition : Xiamen

  • Garantie : 12 mois

Quantité
Voir les détails complets

Description

Providing extended local system expansion directly from the CX2000 Embedded PC series, the Beckhoff CX2550-0179 functions as a high-reliability transmitter module for USB signals. This unit transmits USB 1.1 data packets over extensive plant floor runs, facilitating a secure link between the central processor and a remote operator interface such as the CP69xx-xxxx-0000 series control panels. By utilizing the proprietary USB Extended technology, it eliminates the need for active signal repeaters while maintaining deterministic communication.

Key Features

  • Direct physical and electrical integration with the left-side system connection of CX20xx Embedded PCs.
  • Transmission of USB 1.1 signals up to a maximum distance of 50 meters.
  • Utilizes standard, cost-effective Cat.5E shielded twisted-pair cabling for physical transport.
  • Integrated RJ45 connection socket designed for high mechanical retention in high-vibration panels.
  • Zero-configuration operation via system bus power routing, requiring no external power supply wiring.
  • Four diagnostic LEDs providing direct status visibility for Power, Speed, +15 V, and Suspend states.

Applications

  • Decentralized visualization panels (CP69xx-xxxx-0000) mounted on machine swing arms.
  • Remote human-machine interfaces (HMI) located away from high-noise electrical cabinets.
  • Long-range peripheral configuration and diagnostic ports in assembly lines.

Technical Specifications

Specification Parameter Value / Details
Manufacturer Beckhoff Automation
Model Number CX2550-0179
Interface Type 1 x USB Extended 1.1 Transmitter
Physical Connection RJ45 Shielded Socket
Transmission Distance Max. 50 m via Cat.5E cable
Power Supply Via system bus (powered through CX2100-0xxx power supply modules)
LED Diagnostics 1 x Power, 1 x Speed, 1 x +15 V, 1 x Suspend
Operating Temperature -25 to +60 degC
Storage Temperature -40 to +85 degC
Relative Humidity 95%, non-condensing
Protection Rating IP20
Dimensions (W x H x D) 24 mm x 99 mm x 54.5 mm
Net Weight 190 g
Vibration/Shock Resistance Conforms to EN 60068-2-6 / EN 60068-2-27
EMC Immunity/Emission Conforms to EN 61000-6-2 / EN 61000-6-4

Empirical Engineering Insights

Alternative Models & Compatibility

The CX2550-0179 is designed exclusively as a USB 1.1 transmitter. If your target peripheral or remote HMI requires USB 2.0 speeds (e.g., for external storage, heavy file transfers, or modern touch controllers requiring USB 2.0 bandwidth), the CX2550-0079 should be used instead. Note that the transmitter module must always match the capability of the receiver card built into the CP69xx control panel series.

Application Pitfalls & Engineering Notes

When calculating thermal dissipation inside compact, unventilated electrical cabinets, factor in the 190 g modules continuous heat output alongside the main CX CPU module. To ensure consistent signal integrity, avoid parallel routing of the Cat.5E connection cable with high-voltage AC motor drives or heavy contactor supply lines. While the unit complies with EN 61000-6-2 industrial immunity standards, severe electromagnetic fields can trigger transient packet drops, causing the 'Suspend' LED to toggle.

Commissioning & Wiring Tips

Always utilize STP (Shielded Twisted Pair) Cat.5E cabling with fully metal-shielded RJ45 plugs. Ensure the metal shielding on the cable makes direct contact with the grounding shroud of the RJ45 socket on both the CX2550-0179 transmitter and the receiver unit. If the grounding path is compromised, electrostatic build-up may cause communication interruptions or require a cold reboot of the CX20xx controller.

Installation Guidelines

CRITICAL WARNING:

Do not install or remove the CX2550-0179 transmitter module while the central control system is powered. Ensure the primary CX2100-0xxx power supply module is completely de-energized and wait at least 30 seconds for all residual capacitance to bleed down before mechanical mounting. Failure to comply can result in permanent damage to the multi-pin PC/104 system bus interface.

1
Disconnect all power from the main control panel and verify that the system is safe to touch.
2
Align the CX2550-0179 guide pins with the left-hand expansion connector of the CX20xx CPU module.
3
Press the two units together gently until the locking mechanism fully clicks, verifying a gap-free fit.
4
Insert the shielded Cat.5E patch cable into the RJ45 port until it locks in place, ensuring the cable strain relief is secure.
5
Re-energize the power supply module. Confirm the Power and diagnostic LEDs light up, indicating communication initialization with the TwinCAT platform.
Loading product navigation…

What is the maximum cable distance supported by the CX2550-0179?

The CX2550-0179 transmitter module supports a maximum transmission distance of up to 50 meters when using a standard high-quality Cat.5E or higher shielded copper Ethernet cable.

Does this module support USB 2.0 or USB 3.0 devices?

No, this module is strictly designed for USB 1.1 protocol rates. For applications requiring USB 2.0 standard bandwidth and speeds, you must utilize the CX2550-0079 module.

Does the CX2550-0179 require a dedicated external power supply wiring?

No, the module is powered directly from the internal system bus of the host controller, drawing its working current through the integrated connection interface of the CX2100 power supply.

What do the diagnostics LEDs indicate on the front panel of the module?

The module features four active status LEDs: 'Power' indicates general internal voltage presence, 'Speed' reflects active data transmission, '+15 V' confirms correct voltage supply to the interface circuitry, and 'Suspend' illuminates when the connected USB device enters low-power standby mode.

Expédition express mondiale

  • Livraison standard : 4 à 6 jours ouvrables via DHL, FedEx et UPS.
  • Expédition express : Expédition le jour même pour les commandes en stock passées avant 14h00 (GMT+8).
  • Couverture mondiale : Service dans plus de 150 pays, avec livraison rapide en Arabie Saoudite et aux Émirats arabes unis.

Retours et garantie

  • Garantie de 30 jours : Retours acceptés pour les produits en stock dans leur emballage d'origine scellé en usine.
  • Garantie de 12 mois : Chaque composant industriel est couvert par notre garantie technique professionnelle.

Les commandes sont traitées et livrées du lundi au vendredi (hors jours fériés).


Pour connaître l'éligibilité complète, les frais de restockage et les détails des retours internationaux, veuillez consulter notre site officiel Politique de remboursement et de retour .

TECHNICAL SPECIFICATIONS

Country of origin
Allemagne

Produits récemment consultés

Connaissances techniques

Actionneurs électriques conçus pour remplacer les systèmes à fluide : un guide pratique d'automatisation industrielle

Cet article explique comment les actionneurs électriques intégrés, tels que la série e-Actuator de SMC, transforment le contrôle du mouvement industriel en remplaçant les systèmes pneumatiques et...

Opérations mathématiques avec OpenPLC pour les applications d'automatisation industrielle

Cet article explique comment les systèmes PLC réalisent des opérations mathématiques de base telles que l'addition, la soustraction, la multiplication, la division, le modulo et l'exponentiation dans...

Logique booléenne avancée avec la programmation FBD PLC : applications industrielles pratiques au-delà de la logique de base

L'article explique plusieurs fonctions avancées de la logique booléenne utilisées en programmation d'automates programmables industriels (API) au-delà des opérations de base ET, OU et NON. Il aborde...

Logique booléenne en programmation PLC : comprendre les portes logiques FBD

La logique booléenne est la base de tout programme PLC. Des commandes machines simples aux systèmes d'automatisation industrielle complexes, les portes logiques déterminent comment les contrôleurs...

Guide approfondi sur les pare-feux industriels et la segmentation des réseaux OT

Les pare-feux industriels jouent un rôle crucial dans la cybersécurité OT, protégeant les réseaux PLC, DCS et SCADA grâce à la segmentation, au contrôle des entrées/sorties et à l’intégration IDS/IPS...

Guide des pinces robotiques : de la manipulation délicate à l'automatisation lourde

Les pinces robotiques modernes évoluent au-delà des mâchoires mécaniques traditionnelles. Des systèmes adhésifs inspirés des geckos aux pinces souples de qualité alimentaire, en passant par des...