Il ne reste que 10 article(s) en stock
  • Fabricant : BECKHOFF

  • N° de produit : CX2550-0279

  • Pays d'origine :Allemagne

  • Type de produit : Extendeur USB 2.0 Tx pour CX20xx (CP29xx-0000)

  • Paiement : Virement bancaire, Western Union

  • Poids : 500g

  • Dimensions : 24 mm x 99 mm x 54.5 mm

  • Port d'expédition : Xiamen

  • Garantie : 12 mois

Quantité
Voir les détails complets

Description

The Beckhoff CX2550-0279 functions as a direct system-bus expansion module designed for CX20xx Embedded PCs, enabling remote USB 2.0 signal transmission up to 50 meters. This transmitter module mounts directly to the left-hand side of a CX20xx CPU block, converting standard internal USB lines into a serialized differential signal suitable for long-distance runs over standard Ethernet-style physical media. This setup is specifically optimized for connecting control panels such as the CP29xx-0000 series without signal degradation or latency spikes, ensuring seamless peripheral integration in complex industrial environments.

Key Features

  • Dedicated 1 x USB Extended 2.0 interface utilizing a rugged RJ45 connection port.
  • Reliable signal extension up to a maximum distance of 50 meters over standard Cat.5E or higher shielded cabling.
  • Native system bus integration drawing power directly through preceding CX2100-0xxx power supply units.
  • On-board LED diagnostic indicators for real-time status validation (Power, Host, Activity, and Link status).
  • Compact 24 mm form factor designed for high-density DIN-rail mounting configurations.

Applications

  • Connecting decentralized HMI and operator screens (CP29xx-0000 series) in scattered manufacturing cells.
  • Extending USB diagnostic interfaces outside enclosed, high-voltage electrical panels.
  • Facilitating clean wiring routing in modern modular production lines and material handling facilities.

Technical Specifications

Specification Parameter Technical Value
Manufacturer Beckhoff
Model Number CX2550-0279
Interface Type 1 x USB Extended 2.0 (via RJ45 socket)
Maximum Cable Length 50 meters (using Cat.5E cabling)
Power Feed Via system bus (through CX2100-0xxx modules)
LED Diagnostics Power (1x), Host (1x), Activity (1x), Link (1x)
Dimensions (W x H x D) 24 mm x 99 mm x 54.5 mm
Weight Approximately 190 g
Operating Temperature -25 to +60 degC
Storage Temperature -40 to +85 degC
Relative Humidity 95%, non-condensing
Protection Rating IP20
Vibration/Shock Resistance Conforms to EN 60068-2-6 / EN 60068-2-27
EMC Immunity/Emission Conforms to EN 61000-6-2 / EN 61000-6-4

Connections and Interfaces

Port Type Connector Pinout / LED Signal Description
RJ45 Output Port Pins 1 to 8 Differential USB transmission pairs over Cat.5E shielded line. Do not connect to Ethernet switches.
LED: PWR On (Green) Internal system power is successfully applied via the system bus.
LED: HOST On (Green) Established connection with the primary CX20xx CPU host interface.
LED: LINK On (Green) Active connection established with the remote CP29xx receiver.

Empirical Engineering Insights

Alternative Models & Compatibility

This module behaves specifically as a Point-to-Point Transmitter (Tx) and must be paired with an appropriate receiver, typically integrated directly into Beckhoff CP29xx-0000 Control Panels or external receiver boxes. It is physically designed to slide and snap into place on the left-side expansion slot of the CX20xx series. Ensure your CPU configuration in TwinCAT recognizes the additional module on the PC-system bus before commissioning.

Application Pitfalls & Engineering Notes

A common error on-site is treating the physical RJ45 interface on the front of this unit as an Ethernet network port. Patching this connection into a standard LAN switch, router, or hub can cause immediate electrical damage to either the network hardware or the internal transceiver circuitry of the controller. Keep the extension path strictly point-to-point.

Commissioning & Wiring Tips

For transmissions reaching near the 50-meter limit, always use high-quality, double-shielded copper cabling (S/FTP Cat.5E or Cat.6). Avoid routing this physical-layer run in close proximity to high-frequency variable frequency drive (VFD) output cables or high-voltage lines, as noise coupling on the differential lines can cause momentary dropouts in panel mouse/keyboard and touch signals.

Installation Guidelines

CRITICAL WARNING: Prior to snapping this expansion unit onto the CX20xx CPU module or altering any interface cables, ensure the entire controller rack and any connected remote displays are completely powered down. Verify that no residual voltages are present in the power supply line. Failure to de-energize can damage sensitive differential transceiver chips on the system bus.
1
Align the male multi-pin system-bus connector of the CX2550-0279 with the left-side female interface of the CX20xx CPU unit. Ensure the DIN-rail locking clips are pulled out.
2
Press the module firmly into place until you hear it click, securing it to the adjacent CPU module. Push the DIN-rail locking clips back in to anchor the module on the DIN rail.
3
Insert your dedicated Cat.5E shielded line into the front RJ45 socket and route directly to the panel receiver module, keeping it separate from high-interference power lines.
Loading product navigation…

Can I connect this transmitter directly to a standard network switch or router?

No. The RJ45 interface uses a specialized proprietary physical layer to transmit differential USB signals. Connecting this port to an Ethernet switch or network device can damage the internal components of both units.

What is the maximum cable length supported by this module?

The module supports point-to-point connections up to a maximum distance of 50 meters. To reach this distance, use high-quality shielded Cat.5E or Cat.6 cabling.

Where does this module receive its operating power?

The device draws its power directly from the system bus connected to the adjacent CPU block, which is powered through standard CX2100-0xxx power supply units.

Expédition express mondiale

  • Livraison standard : 4 à 6 jours ouvrables via DHL, FedEx et UPS.
  • Expédition express : Expédition le jour même pour les commandes en stock passées avant 14h00 (GMT+8).
  • Couverture mondiale : Service dans plus de 150 pays, avec livraison rapide en Arabie Saoudite et aux Émirats arabes unis.

Retours et garantie

  • Garantie de 30 jours : Retours acceptés pour les produits en stock dans leur emballage d'origine scellé en usine.
  • Garantie de 12 mois : Chaque composant industriel est couvert par notre garantie technique professionnelle.

Les commandes sont traitées et livrées du lundi au vendredi (hors jours fériés).


Pour connaître l'éligibilité complète, les frais de restockage et les détails des retours internationaux, veuillez consulter notre site officiel Politique de remboursement et de retour .

TECHNICAL SPECIFICATIONS

Country of origin
Allemagne

Produits récemment consultés

Connaissances techniques

Actionneurs électriques conçus pour remplacer les systèmes à fluide : un guide pratique d'automatisation industrielle

Cet article explique comment les actionneurs électriques intégrés, tels que la série e-Actuator de SMC, transforment le contrôle du mouvement industriel en remplaçant les systèmes pneumatiques et...

Opérations mathématiques avec OpenPLC pour les applications d'automatisation industrielle

Cet article explique comment les systèmes PLC réalisent des opérations mathématiques de base telles que l'addition, la soustraction, la multiplication, la division, le modulo et l'exponentiation dans...

Logique booléenne avancée avec la programmation FBD PLC : applications industrielles pratiques au-delà de la logique de base

L'article explique plusieurs fonctions avancées de la logique booléenne utilisées en programmation d'automates programmables industriels (API) au-delà des opérations de base ET, OU et NON. Il aborde...

Logique booléenne en programmation PLC : comprendre les portes logiques FBD

La logique booléenne est la base de tout programme PLC. Des commandes machines simples aux systèmes d'automatisation industrielle complexes, les portes logiques déterminent comment les contrôleurs...

Guide approfondi sur les pare-feux industriels et la segmentation des réseaux OT

Les pare-feux industriels jouent un rôle crucial dans la cybersécurité OT, protégeant les réseaux PLC, DCS et SCADA grâce à la segmentation, au contrôle des entrées/sorties et à l’intégration IDS/IPS...

Guide des pinces robotiques : de la manipulation délicate à l'automatisation lourde

Les pinces robotiques modernes évoluent au-delà des mâchoires mécaniques traditionnelles. Des systèmes adhésifs inspirés des geckos aux pinces souples de qualité alimentaire, en passant par des...