Engineered for high-performance automation and control tasks, the Beckhoff CX5130-0140 serves as a robust embedded PC CPU module within the modular CX5100 series. Equipped with an Intel Atom E3827 dual-core processor running at 1.75 GHz, this controller offers efficient processing power with optimized energy consumption for industrial environments. The unit features built-in I/O auto-recognition, allowing seamless integration with both Beckhoff E-bus (EtherCAT Terminals) and K-bus (Bus Terminals) systems directly on the DIN rail.

This controller features 4 GB of non-expandable DDR3 RAM, redundant flash card slots for CFast and microSD storage, and a built-in 1-second UPS to ensure persistent data preservation of up to 1 MB in the event of power loss. Designed for flexibility in fieldbus connectivity and software runtimes, it supports Windows Embedded, Windows 10 IoT, and TwinCAT/BSD operating platforms, making it ideal for standard PLC applications, motion control, and high-speed data acquisition.

Features

  • Dual-Core Processor: Intel Atom E3827 processor operating at 1.75 GHz for efficient execution of PLC and motion control cycles.
  • Unified I/O Interface: Automatic recognition and support for both K-bus and E-bus (EtherCAT) terminal systems.
  • Integrated Persistent Storage: Built-in 1-second UPS saves up to 1 MB of critical data to the CFast card upon unexpected power disruption.
  • Dual Storage Expansion: Dedicated slots for both CFast and microSD cards to segregate operating systems, programs, and log files.
  • Flexible Communication Ports: Dual independent Gigabit Ethernet interfaces, four USB 2.0 ports, and one high-resolution DVI-I connection.

Applications

  • Heavy machine automation and precision motion control systems.
  • Distributed power generation monitoring and utility control.
  • Process control systems requiring space-saving DIN rail mounting.
  • Water and wastewater plant control and monitoring panels.

Technical Specifications

Manufacturer Beckhoff
Model/Part Number CX5130-0140
Processor Intel Atom E3827, 1.75 GHz, 2 Cores
Memory 4 GB DDR3 RAM (non-expandable)
Storage Interfaces 1 x CFast card slot, 1 x microSD card slot
Persistent Memory Integrated 1-second UPS, 1 MB on CFast card
Ethernet Interfaces 2 x RJ45 10/100/1000 Mbit/s (independent)
USB Interfaces 4 x USB 2.0
Video Output 1 x DVI-I
I/O Connection Type E-bus (EtherCAT) or K-bus (Bus Terminals), auto-detection
Diagnostics LEDs 1 x Power, 1 x TC Status, 1 x Flash Access, 2 x Bus Status
Power Supply 24 V DC (-15 percent / +20 percent)
E-bus/K-bus Power Supply Current 2 A
Maximum Power Consumption 14 W (20 W while charging persistent memory UPS)
Operating Temperature -25 degC to +60 degC
Storage Temperature -40 degC to +85 degC
Relative Humidity 95 percent, non-condensing
Dimensions (W x H x D) 142 mm x 100 mm x 92 mm
Weight 1095 g
Protection Rating IP20

Connections and Interfaces

Interface Type Connector / Port Type Functional Description
LAN 1 / LAN 2 RJ45 (Gigabit Ethernet) Network communication and TwinCAT EtherCAT connection
DVI-I DVI Female Connector Analog/Digital monitor output connection
USB 1-4 USB Type A Connection for peripheral devices and memory drives
Power Supply Terminal Block 24 V DC system power input and functional earth grounding
Bus Connection E-Bus / K-Bus Contact Rail Internal bus connection to adjacent I/O modules

Installation Guidelines

  • Mounting: Mount horizontally on standard 35 mm DIN rail (EN 60715). Ensure correct interlocking on the mounting rail.
  • Ventilation: Maintain at least 30 mm of free space above and below the module to allow natural convection cooling. Do not block venting slots.
  • Grounding: Connect the functional earth grounding directly to the low-impedance DIN rail via the integrated grounding spring on the back panel.
  • Power Supply Connection: Ensure supply lines are properly fused and use conductors matching the nominal load current and voltage drops.

Compliance and Certifications

  • CE: Conforms to European electromagnetic compatibility standards EN 61000-6-2 and EN 61000-6-4.
  • UL: Listed for safety standard UL 508.
  • DNV GL: Certified for marine and offshore installations.
  • Hazardous Location (ATEX/IECEx/cFMus): Conforms to ATEX: II 3 G Ex nA IIC T4 Gc and II 3 D Ex tc IIIC T135 degC Dc (when ordered with the CX2900-0107 option).
Loading product navigation…

What is the primary difference between the E-bus and K-bus connections on the Beckhoff CX5130-0140?

The CX5130-0140 features auto-recognition for the backplane bus. If EtherCAT Terminals (ELxxxx) are attached, the module utilizes the high-speed E-bus. If standard Bus Terminals (KLxxxx) are connected, it automatically switches to the K-bus protocol.

How does the integrated 1-second UPS operate in the CX5130-0140?

In the event of a power loss, the built-in UPS supplies power for approximately 1 second. This duration is sufficient for the system to write up to 1 MB of critical persistent data onto the CFast storage card.

Can the 4 GB DDR3 RAM in this module be upgraded?

No, the 4 GB DDR3 RAM is integrated directly onto the motherboard and is non-expandable.

Are storage cards included with the CX5130-0140 CPU module?

No, CFast and microSD cards must be ordered separately as they are not included in the standard delivery.

What TwinCAT 3 platform level applies to this processor?

The Beckhoff CX5130-0140 belongs to the TwinCAT 3 Performance platform level (level 40).

Expédition express mondiale

  • Livraison standard : 4 à 6 jours ouvrables via DHL, FedEx et UPS.
  • Expédition express : Expédition le jour même pour les commandes en stock passées avant 14h00 (GMT+8).
  • Couverture mondiale : Service dans plus de 150 pays, avec livraison rapide en Arabie Saoudite et aux Émirats arabes unis.

Retours et garantie

  • Garantie de 30 jours : Retours acceptés pour les produits en stock dans leur emballage d'origine scellé en usine.
  • Garantie de 12 mois : Chaque composant industriel est couvert par notre garantie technique professionnelle.

Les commandes sont traitées et livrées du lundi au vendredi (hors jours fériés).


Pour connaître l'éligibilité complète, les frais de restockage et les détails des retours internationaux, veuillez consulter notre site officiel Politique de remboursement et de retour .

TECHNICAL SPECIFICATIONS

Country of origin
Allemagne

Produits récemment consultés

Connaissances techniques

Actionneurs électriques conçus pour remplacer les systèmes à fluide : un guide pratique d'automatisation industrielle

Cet article explique comment les actionneurs électriques intégrés, tels que la série e-Actuator de SMC, transforment le contrôle du mouvement industriel en remplaçant les systèmes pneumatiques et...

Opérations mathématiques avec OpenPLC pour les applications d'automatisation industrielle

Cet article explique comment les systèmes PLC réalisent des opérations mathématiques de base telles que l'addition, la soustraction, la multiplication, la division, le modulo et l'exponentiation dans...

Logique booléenne avancée avec la programmation FBD PLC : applications industrielles pratiques au-delà de la logique de base

L'article explique plusieurs fonctions avancées de la logique booléenne utilisées en programmation d'automates programmables industriels (API) au-delà des opérations de base ET, OU et NON. Il aborde...

Logique booléenne en programmation PLC : comprendre les portes logiques FBD

La logique booléenne est la base de tout programme PLC. Des commandes machines simples aux systèmes d'automatisation industrielle complexes, les portes logiques déterminent comment les contrôleurs...

Guide approfondi sur les pare-feux industriels et la segmentation des réseaux OT

Les pare-feux industriels jouent un rôle crucial dans la cybersécurité OT, protégeant les réseaux PLC, DCS et SCADA grâce à la segmentation, au contrôle des entrées/sorties et à l’intégration IDS/IPS...

Guide des pinces robotiques : de la manipulation délicate à l'automatisation lourde

Les pinces robotiques modernes évoluent au-delà des mâchoires mécaniques traditionnelles. Des systèmes adhésifs inspirés des geckos aux pinces souples de qualité alimentaire, en passant par des...