Designed for high-precision temperature sensing in distributed control architectures, the Beckhoff EJ3202 is a dual-channel EtherCAT plug-in module designed for direct mounting on application-specific signal distribution boards. This space-saving module enables direct connection of Resistance Temperature Detectors (RTD) using 2-wire or 3-wire cabling methods. By supporting a broad range of RTD sensors like Pt100, Pt1000, and Ni100, the module delivers highly accurate temperature measurement capabilities directly into the EtherCAT communication network, making it highly suitable for demanding industrial machinery and automation environments.

Features

  • Two independent channels for RTD input.
  • Supports 2-wire and 3-wire connection configurations (2-wire as default).
  • Compatible with a wide array of temperature sensors: Pt100, Pt200, Pt500, Pt1000, Ni100, Ni120, Ni1000, and KTY sensors.
  • Integrated digital filter and configurable limit value monitoring for enhanced process control.
  • Direct installation onto EJ-series signal distribution boards, minimizing wiring complexity and footprint.
  • Provides 500 V electrical isolation between the E-bus and field potential.

Applications

  • Machinery and equipment manufacturing with customized signal boards.
  • Industrial furnace and HVAC control systems.
  • Process manufacturing requiring precise thermal profiling.
  • Food and beverage production lines requiring clean, distributed I/O installations.

Technical Specifications

Manufacturer Beckhoff
Part Number / Model EJ3202
Technology Temperature measurement (RTD)
Number of Inputs 2
Connection Method 2- or 3-wire (default: 2-wire)
Sensor Types Pt100, Pt200, Pt500, Pt1000, Ni100, Ni120, Ni1000, resistance measurement (e.g. potentiometer 10 Ohm to 1/4 kOhm), KTY sensors
Measuring Range -200 to +850 degC (Pt sensors); -60 to +250 degC (Ni sensors)
Resolution 0.1 degC per digit
Measurement Error / Uncertainty < +/-0.5 degC for Pt sensors
Input Filter Limit Frequency typ. 1 kHz
Conversion Time approx. 85 ms default setting (2 to 800 ms configurable)
Power Supply via the E-bus
Current Consumption E-bus typ. 165 mA
Electrical Isolation 500 V (E-bus/field potential)
Special Features Integrated digital filter, limit value monitoring, variable connection technology
Weight approx. 30 g
Operating Temperature -25 to +60 degC
Storage Temperature -40 to +85 degC
Relative Humidity 95 %, non-condensing
EMC Immunity/Emission Conforms to EN 61000-6-2/EN 61000-6-4
Vibration/Shock Resistance Conforms to EN 60068-2-6/EN 60068-2-27
Protection Rating IP20

Installation Guidelines

  • Mounting: Ensure the module is properly plugged into the matching application-specific signal distribution board. Confirm latching mechanism is secure before powering the system.
  • Wiring: For 3-wire connections, ensure all lead wires have equal resistance to minimize measuring errors. Keep sensor cables separate from high-voltage motor cables to prevent electromagnetic noise coupling.
  • Thermal Management: Maintain standard operating ambient temperature range of -25 to +60 degC. Ensure adequate clearance for convection cooling inside the enclosure.
  • Grounding: Connect shielding of the RTD cables directly to the ground bus at the entry point of the control panel to minimize external interference.

Compliance and Certifications

  • CE
  • UL
Loading product navigation…

What sensor types are compatible with the Beckhoff EJ3202?

The EJ3202 supports a wide variety of RTD sensors, including Pt100, Pt200, Pt500, Pt1000, Ni100, Ni120, Ni1000, KTY sensors, and general resistance measurements (such as potentiometers ranging from 10 Ohm to 1/4 kOhm).

Does the EJ3202 module support 3-wire RTD measurements?

Yes, the EJ3202 supports both 2-wire and 3-wire connection methods. By default, the module is configured for 2-wire connection technology.

What is the typical measurement accuracy of the EJ3202 when using Pt sensors?

The measurement error or uncertainty for the EJ3202 when utilizing standard Pt sensors is less than +/-0.5 degC.

What is the operating temperature range for the Beckhoff EJ3202 plug-in module?

The EJ3202 is rated for an operating temperature range of -25 to +60 degC and a storage temperature range of -40 to +85 degC.

Expédition express mondiale

  • Livraison standard : 4 à 6 jours ouvrables via DHL, FedEx et UPS.
  • Expédition express : Expédition le jour même pour les commandes en stock passées avant 14h00 (GMT+8).
  • Couverture mondiale : Service dans plus de 150 pays, avec livraison rapide en Arabie Saoudite et aux Émirats arabes unis.

Retours et garantie

  • Garantie de 30 jours : Retours acceptés pour les produits en stock dans leur emballage d'origine scellé en usine.
  • Garantie de 12 mois : Chaque composant industriel est couvert par notre garantie technique professionnelle.

Les commandes sont traitées et livrées du lundi au vendredi (hors jours fériés).


Pour connaître l'éligibilité complète, les frais de restockage et les détails des retours internationaux, veuillez consulter notre site officiel Politique de remboursement et de retour .

TECHNICAL SPECIFICATIONS

Country of origin
Allemagne

Produits récemment consultés

Connaissances techniques

Actionneurs électriques conçus pour remplacer les fluides : tutoriel pratique

This article explains how integrated electric actuators, such as SMC’s e-Actuator series, are transforming industrial motion control by replacing traditional pneumatic and hydraulic systems. It...

Opérations mathématiques avec OpenPLC pour les applications d'automatisation industrielle

Cet article explique comment les systèmes PLC réalisent des opérations mathématiques de base telles que l'addition, la soustraction, la multiplication, la division, le modulo et l'exponentiation dans...

Logique booléenne avancée avec la programmation FBD PLC : applications industrielles pratiques au-delà de la logique de base

L'article explique plusieurs fonctions avancées de la logique booléenne utilisées en programmation d'automates programmables industriels (API) au-delà des opérations de base ET, OU et NON. Il aborde...

Logique booléenne en programmation PLC : comprendre les portes logiques FBD

La logique booléenne est la base de tout programme PLC. Des commandes machines simples aux systèmes d'automatisation industrielle complexes, les portes logiques déterminent comment les contrôleurs...

Guide approfondi sur les pare-feux industriels et la segmentation des réseaux OT

Les pare-feux industriels jouent un rôle crucial dans la cybersécurité OT, protégeant les réseaux PLC, DCS et SCADA grâce à la segmentation, au contrôle des entrées/sorties et à l’intégration IDS/IPS...

Guide des pinces robotiques : de la manipulation délicate à l'automatisation lourde

Les pinces robotiques modernes évoluent au-delà des mâchoires mécaniques traditionnelles. Des systèmes adhésifs inspirés des geckos aux pinces souples de qualité alimentaire, en passant par des...