1 of 1

EL3692 | BECKHOFF | Terminal EtherCAT

EL3692 | BECKHOFF | Terminal EtherCAT

Il ne reste que 10 article(s) en stock
  • Fabricant : BECKHOFF

  • N° de produit : EL3692

  • Pays d'origine :Allemagne

  • Type de produit : Bornier EtherCAT

  • Paiement : Virement bancaire, Western Union

  • Poids : 55g

  • Dimensions : 12 mm x 100 mm x 68 mm

  • Port d'expédition : Xiamen

  • Garantie : 12 mois

Quantité
Voir les détails complets

Description

Designed for high-precision resistance measurements, the Beckhoff EL3692 is a 2-channel analog input EtherCAT Terminal capable of reading values from 100 mΩ up to 10 MΩ. It features a high-resolution 24-bit analog-to-digital converter and supports both 2-wire and 4-wire connection configurations to eliminate lead wire resistance errors. Integrating seamlessly into standard EtherCAT networks, this module provides fast, reliable, and highly stable data acquisition for industrial sensors, potentiometers, and variable resistance devices.

The EL3692 dynamically manages measuring ranges through automatic range selection or direct PLC controller configuration. Additionally, it provides built-in wiring failure detection to alert systems of open circuits, ensuring maximum operational safety and diagnostics in critical process control applications.

Features

  • Two high-resolution (24-bit) analog input channels dedicated to resistance measurements.
  • Broad measuring span from 100 mΩ up to 10 MΩ.
  • Flexible technology supporting both 2-wire and 4-wire connection methods.
  • Automatic or controller-driven range switching.
  • Pulse and continuous measurement modes for minimized power dissipation and self-heating.
  • Integrated wire failure diagnostics.
  • Galvanic isolation of 1500 V between the E-bus and the field potential.
  • Compact 12 mm terminal housing designed for efficient space utilization on DIN rails.

Applications

  • Precision RTD and temperature sensor monitoring.
  • Industrial testing benches and quality control systems.
  • Strain gauge and potentiometer monitoring in manufacturing environments.
  • Heavy duty automation systems requiring precise resistance tracking.

Technical Specifications

Manufacturer BECKHOFF
Model / Part Number EL3692
Number of Inputs 2
Power Supply Via the E-bus
Technology 2-wire or 4-wire resistance measurement
Signal Type Single-ended
Measuring Ranges 100 mΩ, 1 Ω, 10 Ω, 100 Ω, 1 kΩ, 10 kΩ, 100 kΩ, 1 MΩ, 10 MΩ
Resolution 24 bit
Measuring Error < ±0.5% (relative to full scale value with 4-wire connection)
Internal Resistance > 100 MΩ
Input Filter Limit Frequency 100 Hz
Conversion Time Typically 10 to 400 ms (dependent on measuring range and settings)
E-bus Current Consumption Typically 220 mA
Electrical Isolation 1500 V (E-bus / field potential)
Dimensions (W x H x D) 12 mm x 100 mm x 68 mm
Weight Approx. 55 g
Operating Temperature 0 to +55 degC
Storage Temperature -25 to +85 degC
Relative Humidity 95%, non-condensing
IP Rating IP20
Material Polycarbonate

Connections and Interfaces

Connection Type Conductor Cross-section AWG Range
Solid Wire (s) 0.08 to 2.5 mm² AWG 28 to 14
Stranded Wire (st) 0.08 to 2.5 mm² AWG 28 to 14
Flexible Conductor with Ferrule (f) 0.14 to 1.5 mm² AWG 26 to 16
Stripping Length 8 to 9 mm -

Installation Guidelines

  • Mount vertically or horizontally on a standard 35 mm DIN rail (conforming to EN 60715) using the integrated locking mechanism.
  • Ensure secure side-by-side terminal contact using the built-in double slot and key connection system.
  • Maintain clear ventilation around the terminal to preserve the ambient operating temperature between 0 and +55 degC.
  • For hazardous area installations, adhere to the certified ATEX guidelines under Ex classification II 3 G Ex nA IIC T4 Gc.

Compliance and Certifications

  • CE
  • UL
  • ATEX: II 3 G Ex nA IIC T4 Gc
Loading product navigation…

What is the measuring range of the Beckhoff EL3692?

The EL3692 supports a wide resistance measuring range from 100 mΩ up to 10 MΩ across several sub-ranges.

Does the EL3692 require an external power supply?

No, the EL3692 is powered directly via the internal E-bus of the EtherCAT Terminal system.

What connection technologies are supported by the EL3692?

The terminal supports both 2-wire and 4-wire resistance measurement technologies for flexible sensor connection.

What is the resolution of this analog input terminal?

The EL3692 offers a high-precision 24-bit resolution.

What hazardous area certifications does the module hold?

The EL3692 is ATEX certified with the marking II 3 G Ex nA IIC T4 Gc for Zone 2 applications.

Expédition express mondiale

  • Livraison standard : 4 à 6 jours ouvrables via DHL, FedEx et UPS.
  • Expédition express : Expédition le jour même pour les commandes en stock passées avant 14h00 (GMT+8).
  • Couverture mondiale : Service dans plus de 150 pays, avec livraison rapide en Arabie Saoudite et aux Émirats arabes unis.

Retours et garantie

  • Garantie de 30 jours : Retours acceptés pour les produits en stock dans leur emballage d'origine scellé en usine.
  • Garantie de 12 mois : Chaque composant industriel est couvert par notre garantie technique professionnelle.

Les commandes sont traitées et livrées du lundi au vendredi (hors jours fériés).


Pour connaître l'éligibilité complète, les frais de restockage et les détails des retours internationaux, veuillez consulter notre site officiel Politique de remboursement et de retour .

TECHNICAL SPECIFICATIONS

Country of origin
Allemagne

Produits récemment consultés

Connaissances techniques

Actionneurs électriques conçus pour remplacer les systèmes à fluide : un guide pratique d'automatisation industrielle

Cet article explique comment les actionneurs électriques intégrés, tels que la série e-Actuator de SMC, transforment le contrôle du mouvement industriel en remplaçant les systèmes pneumatiques et...

Opérations mathématiques avec OpenPLC pour les applications d'automatisation industrielle

Cet article explique comment les systèmes PLC réalisent des opérations mathématiques de base telles que l'addition, la soustraction, la multiplication, la division, le modulo et l'exponentiation dans...

Logique booléenne avancée avec la programmation FBD PLC : applications industrielles pratiques au-delà de la logique de base

L'article explique plusieurs fonctions avancées de la logique booléenne utilisées en programmation d'automates programmables industriels (API) au-delà des opérations de base ET, OU et NON. Il aborde...

Logique booléenne en programmation PLC : comprendre les portes logiques FBD

La logique booléenne est la base de tout programme PLC. Des commandes machines simples aux systèmes d'automatisation industrielle complexes, les portes logiques déterminent comment les contrôleurs...

Guide approfondi sur les pare-feux industriels et la segmentation des réseaux OT

Les pare-feux industriels jouent un rôle crucial dans la cybersécurité OT, protégeant les réseaux PLC, DCS et SCADA grâce à la segmentation, au contrôle des entrées/sorties et à l’intégration IDS/IPS...

Guide des pinces robotiques : de la manipulation délicate à l'automatisation lourde

Les pinces robotiques modernes évoluent au-delà des mâchoires mécaniques traditionnelles. Des systèmes adhésifs inspirés des geckos aux pinces souples de qualité alimentaire, en passant par des...