1 of 1

EL4122 | BECKHOFF | Terminal EtherCAT

EL4122 | BECKHOFF | Terminal EtherCAT

Il ne reste que 10 article(s) en stock
  • Fabricant : BECKHOFF

  • N° de produit : EL4122

  • Pays d'origine :Allemagne

  • Type de produit : Bornier EtherCAT

  • Paiement : Virement bancaire, Western Union

  • Poids : 60g

  • Dimensions : 12 mm x 100 mm x 68 mm

  • Port d'expédition : Xiamen

  • Garantie : 12 mois

Quantité
Voir les détails complets

Description

Designed for high-precision industrial control processes, the BECKHOFF EL4122 is a 2-channel analog output EtherCAT Terminal operating within the 4 to 20 mA range. This module converts digital control values from the automation system into analog current signals with a high-resolution output of 16 bits. Electrically isolated from the E-bus, the terminal ensures reliable operation in noise-prone automation environments. Integrated distributed clock functionality provides highly accurate synchronization, supporting synchronization precision to less than 1 us, making it suitable for applications requiring strict timing alignments.

Features

  • Two channels of analog current outputs supporting a 4 to 20 mA signal range.
  • High-resolution 16-bit digital-to-analog conversion for accurate control.
  • Supports Distributed Clocks (DC) for precise synchronization down to less than 1 us.
  • Short-circuit proof design with load limits under 500 Ohm.
  • Configurable watchdog parameters and customizable user synchronization.
  • Compact 12 mm housing width maximizing DIN rail space.
  • Galvanic isolation of 500 V between the E-bus and the process signal levels.

Applications

  • Proportional valve control and positioning systems.
  • Variable speed drive speed referencing and modulation.
  • Process automation loop controllers in oil, gas, and water utilities.
  • Actuator and physical positioning control loops.
  • General manufacturing automation requiring precise analog setpoints.

Technical Specifications

Manufacturer BECKHOFF
Part Number / Model EL4122
Connection Technology 3-wire, single-ended
Number of Outputs 2
Power Supply 24 V DC via power contacts
Signal Current 4 to 20 mA
Distributed Clocks Yes
Distributed Clock Precision less than 1 us
Load less than 500 Ohm (short-circuit proof)
Output Error less than 0.1 % (relative to end value)
Resolution 16 bit (including sign)
Electrical Isolation 500 V (E-bus / signal voltage)
Output Rate max. 15 ksps
Current Consumption Power Contacts typ. 15 mA + load
Current Consumption E-Bus typ. 160 mA
Bit Width in Process Image 2 x 16 bit AO output
Special Features Watchdog parameterizable, user synchronization activatable
Weight approx. 60 g
Operating Temperature 0 to +55 degC
Storage Temperature -25 to +85 degC
Relative Humidity 95 %, no condensation
IP Rating IP20
Material Polycarbonate
Dimensions (W x H x D) 12 mm x 100 mm x 68 mm

Connections and Interfaces

Connection Parameter Specification
Wiring Type Solid wire, stranded wire, or with ferrule
Actuation Method Spring actuation via screwdriver
Solid Wire Cross-Section 0.08 to 2.5 mm² (AWG 28 to 14)
Stranded Wire Cross-Section 0.08 to 2.5 mm² (AWG 28 to 14)
Ferrule Wire Cross-Section 0.14 to 1.5 mm² (AWG 26 to 16)
Stripping Length 8 to 9 mm
Current Load Power Contacts max. 10 A

Installation Guidelines

  • Mounting: Mount horizontally on a standard 35 mm DIN rail (conforming to EN 60715). Ensure the locking mechanism is securely locked in place.
  • Interconnection: Connect adjacent modules using the double slot and key connection system to ensure continuous E-bus performance.
  • Grounding: Ensure the DIN rail is connected to a clean, noise-free functional earth terminal to preserve the signal integrity of the analog channels.
  • Shielding: Use shielded analog cabling and ground the shields near the terminal entry point to minimize electromagnetically induced noise.

Compliance and Certifications

  • Certifications: CE, UL, ATEX
  • Ex Marking: II 3 G Ex nA IIC T4 Gc
  • EMC Standards: Conforms to EN 61000-6-2 (Immunity) and EN 61000-6-4 (Emission)
  • Vibration / Shock Resistance: Conforms to EN 60068-2-6 and EN 60068-2-27
Loading product navigation…

What is the signal range of the BECKHOFF EL4122?

The EL4122 is designed to output analog current signals within the 4 to 20 mA range across 2 channels.

Does the EL4122 support Distributed Clocks (DC)?

Yes, it supports Distributed Clocks with synchronization precision of less than 1 microsecond.

What is the electrical isolation rating of this EtherCAT Terminal?

The module features galvanic isolation of 500 V between the internal E-bus and the external process signal line.

What wire cross-section sizes are compatible with the EL4122 connections?

It accepts solid and stranded wires from 0.08 to 2.5 mm² (AWG 28 to 14) and wires with ferrules from 0.14 to 1.5 mm² (AWG 26 to 16).

Is the EL4122 rated for hazardous area use?

Yes, it possesses ATEX certification with the Ex marking: II 3 G Ex nA IIC T4 Gc.

Expédition express mondiale

  • Livraison standard : 4 à 6 jours ouvrables via DHL, FedEx et UPS.
  • Expédition express : Expédition le jour même pour les commandes en stock passées avant 14h00 (GMT+8).
  • Couverture mondiale : Service dans plus de 150 pays, avec livraison rapide en Arabie Saoudite et aux Émirats arabes unis.

Retours et garantie

  • Garantie de 30 jours : Retours acceptés pour les produits en stock dans leur emballage d'origine scellé en usine.
  • Garantie de 12 mois : Chaque composant industriel est couvert par notre garantie technique professionnelle.

Les commandes sont traitées et livrées du lundi au vendredi (hors jours fériés).


Pour connaître l'éligibilité complète, les frais de restockage et les détails des retours internationaux, veuillez consulter notre site officiel Politique de remboursement et de retour .

TECHNICAL SPECIFICATIONS

Country of origin
Allemagne

Produits récemment consultés

Connaissances techniques

Actionneurs électriques conçus pour remplacer les systèmes à fluide : un guide pratique d'automatisation industrielle

Cet article explique comment les actionneurs électriques intégrés, tels que la série e-Actuator de SMC, transforment le contrôle du mouvement industriel en remplaçant les systèmes pneumatiques et...

Opérations mathématiques avec OpenPLC pour les applications d'automatisation industrielle

Cet article explique comment les systèmes PLC réalisent des opérations mathématiques de base telles que l'addition, la soustraction, la multiplication, la division, le modulo et l'exponentiation dans...

Logique booléenne avancée avec la programmation FBD PLC : applications industrielles pratiques au-delà de la logique de base

L'article explique plusieurs fonctions avancées de la logique booléenne utilisées en programmation d'automates programmables industriels (API) au-delà des opérations de base ET, OU et NON. Il aborde...

Logique booléenne en programmation PLC : comprendre les portes logiques FBD

La logique booléenne est la base de tout programme PLC. Des commandes machines simples aux systèmes d'automatisation industrielle complexes, les portes logiques déterminent comment les contrôleurs...

Guide approfondi sur les pare-feux industriels et la segmentation des réseaux OT

Les pare-feux industriels jouent un rôle crucial dans la cybersécurité OT, protégeant les réseaux PLC, DCS et SCADA grâce à la segmentation, au contrôle des entrées/sorties et à l’intégration IDS/IPS...

Guide des pinces robotiques : de la manipulation délicate à l'automatisation lourde

Les pinces robotiques modernes évoluent au-delà des mâchoires mécaniques traditionnelles. Des systèmes adhésifs inspirés des geckos aux pinces souples de qualité alimentaire, en passant par des...