Description

Integration of legacy DeviceNet fieldbus topologies into high-speed EtherCAT networks is achieved directly through the EL6752 communication module. This 1-channel terminal operates as a fully functional DeviceNet master (scanner), allowing the connection of up to 63 decentralized DeviceNet slaves to a centralized EtherCAT control loop. The module acts as an efficient bridge, handling local fieldbus diagnostics and signal mapping with high deterministic accuracy.

The BECKHOFF EL6752 features physical and galvanic isolation to protect internal E-bus circuitry from external electrical transients. Its compact 24 mm housing integrates status LEDs for rapid visual diagnostics of bus communication status, network errors, and power supply. This interface is optimal for retrofitting existing manufacturing lines, integrating legacy sensors, and managing distributed I/O systems in heavy industrial environments.

Features

  • Single-channel DeviceNet master (scanner) implementation.
  • Supports standard transmission rates of 125, 250, and 500 kbaud.
  • Controls up to 63 connected DeviceNet fieldbus slaves.
  • Galvanically decoupled 5-pin open style connection interface.
  • Hardware-based diagnostics via status LEDs for rapid troubleshooting.
  • Compact, space-saving 24 mm terminal housing with integrated DIN-rail release.

Applications

  • Factory automation and legacy machinery migration.
  • Automotive assembly line tool integration.
  • Process control systems utilizing distributed DeviceNet I/O.
  • Packaging machinery and material handling systems.

Technical Specifications

ManufacturerPart Number / ModelTechnologyNumber of ChannelsData Transfer RatesInterface TypeMax. Number of SlavesCurrent Consumption (E-bus)Hardware DiagnosticsOperating TemperatureStorage TemperatureRelative HumidityVibration/Shock ResistanceEMC Immunity/EmissionProtection RatingHousing MaterialDimensions (W x H x D)Weight
BECKHOFF
EL6752
DeviceNet master terminal (scanner)
1
125, 250, 500 kbaud
5-pin open-style connector (included), galvanically decoupled
63 slaves
typ. 260 mA
Status LEDs
-25 to +60 degC
-40 to +85 degC
95 %, non-condensing
Conforms to EN 60068-2-6 / EN 60068-2-27
Conforms to EN 61000-6-2 / EN 61000-6-4
IP20
Polycarbonate
24 mm x 100 mm x 52 mm
approx. 70 g

Connections and Interfaces

Terminal Pin Signal / Function
1 V- (DeviceNet Power Supply Ground)
2 CAN_L (CAN Low Signal)
3 Shield (Drain wire connection)
4 CAN_H (CAN High Signal)
5 V+ (DeviceNet Power Supply +24 V DC)

Installation Guidelines

  • Mounting: Mount horizontally or vertically on a standard 35 mm DIN rail conforming to EN 60715. Use the integrated locking mechanism for secure placement.
  • Wiring: Use specialized push-in connections for E-bus communication and the provided 5-pin open style connector for DeviceNet cabling.
  • Shielding & Grounding: Ensure the DeviceNet cable shield is properly terminated at the connector to minimize electromagnetic interference (EMI).
  • Environmental: Maintain operating ambient temperature within -25 degC to +60 degC. Ensure the installation cabinet provides adequate ventilation to achieve an IP20 rating.

Compliance and Certifications

  • CE
  • UL
  • ATEX: II 3 G Ex nA IIC T4 Gc
Loading product navigation…
Key Features:

What is the primary function of the BECKHOFF EL6752 module?

The BECKHOFF EL6752 acts as a 1-channel DeviceNet master (scanner) terminal, enabling the integration of DeviceNet fieldbus devices into a standard EtherCAT control network.

How many DeviceNet slave devices can the EL6752 control?

The EL6752 terminal can support and control up to 63 connected DeviceNet slaves.

What data transfer rates does the EL6752 support?

It supports standard DeviceNet transmission rates of 125 kbaud, 250 kbaud, and 500 kbaud.

Does the EL6752 provide galvanic isolation?

Yes, the 5-pin open style DeviceNet interface is galvanically decoupled from the internal E-bus control circuitry.

What are the environmental operating limits for this terminal?

The operating temperature ranges from -25 to +60 degC, with a maximum non-condensing relative humidity of 95%.

Expédition express mondiale

  • Livraison standard : 4 à 6 jours ouvrables via DHL, FedEx et UPS.
  • Expédition express : Expédition le jour même pour les commandes en stock passées avant 14h00 (GMT+8).
  • Couverture mondiale : Service dans plus de 150 pays, avec livraison rapide en Arabie Saoudite et aux Émirats arabes unis.

Retours et garantie

  • Garantie de 30 jours : Retours acceptés pour les produits en stock dans leur emballage d'origine scellé en usine.
  • Garantie de 12 mois : Chaque composant industriel est couvert par notre garantie technique professionnelle.

Les commandes sont traitées et livrées du lundi au vendredi (hors jours fériés).


Pour connaître l'éligibilité complète, les frais de restockage et les détails des retours internationaux, veuillez consulter notre site officiel Politique de remboursement et de retour .

TECHNICAL SPECIFICATIONS

Country of origin
Allemagne

Produits récemment consultés

Connaissances techniques

Actionneurs électriques conçus pour remplacer les systèmes à fluide : un guide pratique d'automatisation industrielle

Cet article explique comment les actionneurs électriques intégrés, tels que la série e-Actuator de SMC, transforment le contrôle du mouvement industriel en remplaçant les systèmes pneumatiques et...

Opérations mathématiques avec OpenPLC pour les applications d'automatisation industrielle

Cet article explique comment les systèmes PLC réalisent des opérations mathématiques de base telles que l'addition, la soustraction, la multiplication, la division, le modulo et l'exponentiation dans...

Logique booléenne avancée avec la programmation FBD PLC : applications industrielles pratiques au-delà de la logique de base

L'article explique plusieurs fonctions avancées de la logique booléenne utilisées en programmation d'automates programmables industriels (API) au-delà des opérations de base ET, OU et NON. Il aborde...

Logique booléenne en programmation PLC : comprendre les portes logiques FBD

La logique booléenne est la base de tout programme PLC. Des commandes machines simples aux systèmes d'automatisation industrielle complexes, les portes logiques déterminent comment les contrôleurs...

Guide approfondi sur les pare-feux industriels et la segmentation des réseaux OT

Les pare-feux industriels jouent un rôle crucial dans la cybersécurité OT, protégeant les réseaux PLC, DCS et SCADA grâce à la segmentation, au contrôle des entrées/sorties et à l’intégration IDS/IPS...

Guide des pinces robotiques : de la manipulation délicate à l'automatisation lourde

Les pinces robotiques modernes évoluent au-delà des mâchoires mécaniques traditionnelles. Des systèmes adhésifs inspirés des geckos aux pinces souples de qualité alimentaire, en passant par des...