1 of 1

ELX3152-0090 | BECKHOFF | Terminal EtherCAT

ELX3152-0090 | BECKHOFF | Terminal EtherCAT

Il ne reste que 10 article(s) en stock
  • Fabricant : BECKHOFF

  • N° de produit : ELX3152-0090

  • Pays d'origine :Allemagne

  • Type de produit : Bornier EtherCAT

  • Paiement : Virement bancaire, Western Union

  • Poids : 60g

  • Dimensions : 12 mm x 100 mm x 68 mm

  • Port d'expédition : Xiamen

  • Garantie : 12 mois

Quantité
Voir les détails complets

Description

Directing high-precision analog measurements in hazardous environments, the ELX3152-0090 is an intrinsically safe analog input terminal designed for the direct integration of field devices from Zone 0/20 explosion-hazard areas. This 2-channel single-ended interface processes standard 0/4 to 20 mA current signals with 16-bit resolution. Integrated with TwinSAFE SC (Single Channel) technology, the terminal enables safety-supporting signals to be analyzed and utilized within standard industrial control systems, expanding diagnostic depth and process safety across complex control architectures.

Features

  • Direct connection of intrinsically safe field devices from Zone 0/20 and Zone 1/21.
  • Two independent single-ended analog input channels supporting 0 to 20 mA and 4 to 20 mA signals.
  • TwinSAFE SC capability for integrating safety-assisting monitoring functions.
  • High-resolution 16-bit representation for highly accurate field instrument monitoring.
  • Supports Distributed Clocks (DC) for highly synchronized and precise EtherCAT process data acquisition.
  • Advanced internal processing options including activatable digital FIR/IIR filters.
  • Diagnostic compliance with NE43 NAMUR sensor limit specifications.

Applications

  • Oil and gas extraction, processing, and refining facilities.
  • Chemical and petrochemical process plants requiring intrinsic safety (Ex i).
  • Industrial wastewater treatment facilities with explosive gas atmospheres.
  • Pharmaceutical processing lines managing volatile substances.

Technical Specifications

Manufacturer BECKHOFF
Part Number / Model ELX3152-0090
Product Type EtherCAT Terminal (Ex i, TwinSAFE SC)
Number of Inputs 2 (single-ended)
Signal Current Range 0/4...20 mA
Connection Technology 2- or 3-wire (default: 3-wire)
Resolution 16 bit (including sign)
Measuring Error < +/-0.3% (relative to full scale value)
Internal Measuring Resistance typ. 100 Ohm
Input Filter Limit Frequency 5 kHz
Conversion Time typ. 1 ms
Electronics Supply Voltage 24 V DC (via power contacts, powered by ELX9560)
Current Consumption (Power Contacts) typ. 10 mA + load
Current Consumption (E-bus) typ. 85 mA
Distributed Clocks (DC) Yes
Operating Temperature -25 to +60 degC
Storage Temperature -40 to +85 degC
Relative Humidity 95%, non-condensing
Weight approx. 60 g
Dimensions (W x H x D) 12 mm x 100 mm x 68 mm
Housing Material Polycarbonate

Connections and Interfaces

Connection Property Specification / Wire Size
Wiring Type Solid wire, stranded wire, or wire with ferrule (spring-actuated)
Solid Conductor (s) 0.08 to 2.5 mm² (AWG 28...14)
Stranded Conductor (st) 0.08 to 2.5 mm² (AWG 28...14)
Flexible Conductor with Ferrule (f) 0.14 to 1.5 mm² (AWG 26...16)
Stripping Length 8 to 9 mm
Power Contacts 2 blade/spring contacts

Installation Guidelines

  • Mount securely on a standard 35 mm DIN rail conforming to EN 60715 using the locking mechanism.
  • Ensure adjacent terminal modules are locked using the integrated double-slot and key housing connections.
  • Power the terminal exclusively through a certified ELX9560 power supply module to satisfy all intrinsically safe electrical isolation standards.
  • Ensure appropriate spacing and ventilation within the terminal cluster as defined by the hazardous zone class regulations.

Compliance and Certifications

  • CE, UL
  • ATEX: II 3(1)G Ex ec [ia Ga] IIC T4 Gc, II (1)D [Ex ia Da] IIIC, I (M1) [Ex ia Ma] I
  • IECEx: Ex ec [ia Ga] IIC T4 Gc, [Ex ia Da] IIIC, [Ex ia Ma] I
  • cFMus: AIS Class I, II, III, Division 1, Groups A-G; Class I, Division 2, Groups A-D; Class I, Zone 2, AEx ec [ia Ga] IIC T4 Gc
Loading product navigation…

What is the primary function of the Beckhoff ELX3152-0090?

The Beckhoff ELX3152-0090 is a 2-channel analog input EtherCAT Terminal that allows direct measurement of 0/4 to 20 mA current loops from intrinsically safe (Ex i) sensors located in Zone 0/20 and Zone 1/21 hazardous areas.

What is TwinSAFE SC technology and how is it used in this module?

TwinSAFE SC (Single Channel) technology allows analog process values from standard terminals like the ELX3152-0090 to be made available to safety-related networks (TwinSAFE) for auxiliary safety functions, without requiring dedicated, certified safety-only hardware.

What power supply is required for the ELX3152-0090 terminal?

The terminal requires 24 V DC power delivered via the power contacts from an ELX9560 power supply terminal. This ensures compliance with intrinsically safe barrier regulations and appropriate signal isolation.

Expédition express mondiale

  • Livraison standard : 4 à 6 jours ouvrables via DHL, FedEx et UPS.
  • Expédition express : Expédition le jour même pour les commandes en stock passées avant 14h00 (GMT+8).
  • Couverture mondiale : Service dans plus de 150 pays, avec livraison rapide en Arabie Saoudite et aux Émirats arabes unis.

Retours et garantie

  • Garantie de 30 jours : Retours acceptés pour les produits en stock dans leur emballage d'origine scellé en usine.
  • Garantie de 12 mois : Chaque composant industriel est couvert par notre garantie technique professionnelle.

Les commandes sont traitées et livrées du lundi au vendredi (hors jours fériés).


Pour connaître l'éligibilité complète, les frais de restockage et les détails des retours internationaux, veuillez consulter notre site officiel Politique de remboursement et de retour .

TECHNICAL SPECIFICATIONS

Country of origin
Allemagne

Produits récemment consultés

Connaissances techniques

Actionneurs électriques conçus pour remplacer les systèmes à fluide : un guide pratique d'automatisation industrielle

Cet article explique comment les actionneurs électriques intégrés, tels que la série e-Actuator de SMC, transforment le contrôle du mouvement industriel en remplaçant les systèmes pneumatiques et...

Opérations mathématiques avec OpenPLC pour les applications d'automatisation industrielle

Cet article explique comment les systèmes PLC réalisent des opérations mathématiques de base telles que l'addition, la soustraction, la multiplication, la division, le modulo et l'exponentiation dans...

Logique booléenne avancée avec la programmation FBD PLC : applications industrielles pratiques au-delà de la logique de base

L'article explique plusieurs fonctions avancées de la logique booléenne utilisées en programmation d'automates programmables industriels (API) au-delà des opérations de base ET, OU et NON. Il aborde...

Logique booléenne en programmation PLC : comprendre les portes logiques FBD

La logique booléenne est la base de tout programme PLC. Des commandes machines simples aux systèmes d'automatisation industrielle complexes, les portes logiques déterminent comment les contrôleurs...

Guide approfondi sur les pare-feux industriels et la segmentation des réseaux OT

Les pare-feux industriels jouent un rôle crucial dans la cybersécurité OT, protégeant les réseaux PLC, DCS et SCADA grâce à la segmentation, au contrôle des entrées/sorties et à l’intégration IDS/IPS...

Guide des pinces robotiques : de la manipulation délicate à l'automatisation lourde

Les pinces robotiques modernes évoluent au-delà des mâchoires mécaniques traditionnelles. Des systèmes adhésifs inspirés des geckos aux pinces souples de qualité alimentaire, en passant par des...