Designed for decentralized automation tasks in harsh environments, the Beckhoff EP2816-0004 is a high-density digital output module that interfaces directly with the EtherCAT network. This fieldbus-level device features 16 digital channels packaged in a compact, IP67-rated housing. It is engineered to switch binary control signals from the automation controller to actuators, solenoids, or indicators on the machine. By utilizing an M16, 19-pin output connector, the EP2816-0004 provides a centralized wiring point, making it highly compatible with multi-pin connector valve terminals.

The module operates on a nominal 24 V DC control voltage and handles up to 0.5 A per output channel. Each channel is designed with individual short-circuit protection to protect local wiring and system backplanes from overcurrent faults. With integrated support for Distributed Clocks, this EtherCAT Box guarantees highly synchronized signal processing across industrial installations.

Features

  • 16 digital output channels in a robust, space-saving design.
  • Centralized M16 19-pin output connector, optimizing connection to multi-pin valve manifolds.
  • Short-circuit proof outputs rated at 0.5 A per channel (total sum current of 4 A).
  • High-speed switching times with a typical turn-on time of 25 us and turn-off time of 50 us.
  • Distributed Clocks integration ensures precise synchronization with the central PLC controller.
  • Rugged IP65/66/67 construction enables direct machine mounting without an electrical enclosure.

Applications

  • Pneumatic valve terminal integration in industrial packaging lines.
  • Decentralized control of solenoids and actuators in automotive assembly.
  • On-machine I/O distribution for manufacturing machinery with limited enclosure space.
  • Water treatment facilities and process control operations requiring high environmental resistance.

Technical Specifications

ManufacturerPart Number / ModelProtocolBus InterfaceNumber of OutputsOutput ConnectionsLoad TypeNominal Output VoltageMax. Output CurrentSwitching TimesShort-Circuit CurrentDistributed ClocksCurrent Consumption from USAuxiliary Power CurrentPower Supply ConnectionElectrical IsolationOperating TemperatureStorage TemperatureVibration / Shock ResistanceEMC Immunity / EmissionProtection RatingWeight
Beckhoff
EP2816-0004
EtherCAT
2 x M8 socket, shielded, screw type
16
M16 socket, 19-pin
Ohmic, inductive, lamp load
24 V DC (-15% / +20%)
0.5 A per channel (individually short-circuit proof), sum max. 4 A
typ. T_ON: 25 us, typ. T_OFF: 50 us
max. 1.5 A
Yes
120 mA
typ. 20 mA + load
Feed: 1 x M8 male socket (4-pin); Downstream: 1 x M8 female socket (4-pin)
500 V
-25 to +60 degC
-40 to +85 degC
Conforms to EN 60068-2-6 / EN 60068-2-27
Conforms to EN 61000-6-2 / EN 61000-6-4
IP65 / IP66 / IP67 (conforms to EN 60529)
approx. 165 g

Connections and Interfaces

Interface Type Connector Style Function
EtherCAT Bus 2 x M8 socket, shielded Inbound and outbound industrial Ethernet communications
Digital Outputs 1 x M16, 19-pin socket Unified connection for 16 digital control channels
Power Feed 1 x M8 male socket, 4-pin Primary 24 V DC supply input (US/UP)
Power Downstream 1 x M8 female socket, 4-pin Power pass-through to daisy-chained EtherCAT Box modules

Installation Guidelines

  • Mount the module directly to the machine frame or mounting plate using appropriate M3 screws. Ensure the mounting surface is flat to prevent mechanical stress on the housing.
  • To maintain the IP67 protection rating, ensure all unused M8 and M16 connectors are sealed with corresponding protective caps.
  • Establish a reliable ground connection via the metal mounting surface or the functional earth connection point on the module.
  • Observe the maximum allowable sum current of 4 A across all 16 channels to prevent internal power path overload.

Compliance and Certifications

  • CE
  • UL
Loading product navigation…

What is the primary benefit of the M16 19-pin connection on the EP2816-0004?

The M16 19-pin connection consolidates all 16 digital output channels into a single physical interface. This layout is ideal for wiring directly to multi-pin connector valve terminals, minimizing individual cable routing and labor.

What is the total maximum output current supported by the EP2816-0004?

While each individual channel can drive up to 0.5 A, the total sum current across all 16 channels must not exceed 4 A.

Does the EP2816-0004 support precise synchronization across an EtherCAT network?

Yes, this module supports Distributed Clocks, ensuring highly synchronized signal switching matching the requirements of precise automation systems.

Expédition express mondiale

  • Livraison standard : 4 à 6 jours ouvrables via DHL, FedEx et UPS.
  • Expédition express : Expédition le jour même pour les commandes en stock passées avant 14h00 (GMT+8).
  • Couverture mondiale : Service dans plus de 150 pays, avec livraison rapide en Arabie Saoudite et aux Émirats arabes unis.

Retours et garantie

  • Garantie de 30 jours : Retours acceptés pour les produits en stock dans leur emballage d'origine scellé en usine.
  • Garantie de 12 mois : Chaque composant industriel est couvert par notre garantie technique professionnelle.

Les commandes sont traitées et livrées du lundi au vendredi (hors jours fériés).


Pour connaître l'éligibilité complète, les frais de restockage et les détails des retours internationaux, veuillez consulter notre site officiel Politique de remboursement et de retour .

TECHNICAL SPECIFICATIONS

Country of origin
Allemagne

Produits récemment consultés

Connaissances techniques

Actionneurs électriques conçus pour remplacer les systèmes à fluide : un guide pratique d'automatisation industrielle

Cet article explique comment les actionneurs électriques intégrés, tels que la série e-Actuator de SMC, transforment le contrôle du mouvement industriel en remplaçant les systèmes pneumatiques et...

Opérations mathématiques avec OpenPLC pour les applications d'automatisation industrielle

Cet article explique comment les systèmes PLC réalisent des opérations mathématiques de base telles que l'addition, la soustraction, la multiplication, la division, le modulo et l'exponentiation dans...

Logique booléenne avancée avec la programmation FBD PLC : applications industrielles pratiques au-delà de la logique de base

L'article explique plusieurs fonctions avancées de la logique booléenne utilisées en programmation d'automates programmables industriels (API) au-delà des opérations de base ET, OU et NON. Il aborde...

Logique booléenne en programmation PLC : comprendre les portes logiques FBD

La logique booléenne est la base de tout programme PLC. Des commandes machines simples aux systèmes d'automatisation industrielle complexes, les portes logiques déterminent comment les contrôleurs...

Guide approfondi sur les pare-feux industriels et la segmentation des réseaux OT

Les pare-feux industriels jouent un rôle crucial dans la cybersécurité OT, protégeant les réseaux PLC, DCS et SCADA grâce à la segmentation, au contrôle des entrées/sorties et à l’intégration IDS/IPS...

Guide des pinces robotiques : de la manipulation délicate à l'automatisation lourde

Les pinces robotiques modernes évoluent au-delà des mâchoires mécaniques traditionnelles. Des systèmes adhésifs inspirés des geckos aux pinces souples de qualité alimentaire, en passant par des...