Designed for decentralized automation tasks requiring dense digital output distribution directly in the field, the Beckhoff EP2816-0010 EtherCAT Box provides 16 digital outputs in a robust, space-saving enclosure. This IP65/66/67-rated module connects binary control signals from the EtherCAT network directly to actuators and devices, eliminating the need for protective control cabinets and minimizing complex field cabling.

Featuring two 9-pin D-sub socket connections, this module is specifically optimized for direct, hassle-free interfaces with multi-pin connector valve terminals and pneumatic manifold systems. The outputs support ohmic, inductive, and lamp loads with integrated short-circuit protection and electrical isolation up to 500 V, making it highly reliable in demanding manufacturing and process environments.

Features

  • 16 digital output channels in a highly compact, direct-to-field mountable housing.
  • Equipped with two 9-pin D-sub socket connectors tailored for multi-pin valve manifolds.
  • Individually short-circuit proof outputs with 0.5 A maximum output current per channel.
  • Integrated Distributed Clocks functionality for precise synchronization across the EtherCAT network.
  • Rugged environmental design with IP65, IP66, and IP67 ingress protection ratings.
  • EtherCAT communication interface utilizing shielded, screw-type M8 sockets.

Applications

  • Direct integration with pneumatic valve terminals and manifold systems.
  • Decentralized actuator control in automotive assembly and robotic lines.
  • Field-level I/O processing in material handling and packaging systems.
  • General manufacturing automation requiring direct, cabinet-free mounting.

Technical Specifications

Manufacturer Beckhoff
Model/Part Number EP2816-0010
Protocol EtherCAT
Number of Outputs 16
Nominal Output Voltage 24 V DC (-15% / +20%)
Max. Output Current 0.5 A per channel (individually short-circuit proof, total limit 4.0 A)
Short-Circuit Current Max. 1.5 A
Load Types Ohmic, inductive, lamp load
Switching Times (Typical) T ON: 60 us, T OFF: 300 us
Current Consumption (Us) 120 mA
Auxiliary Power Current Typ. 20 mA + load
Distributed Clocks Yes
Electrical Isolation 500 V
Operating Temperature -25 to +60 degC
Storage Temperature -40 to +85 degC
Vibration / Shock Resistance Conforms to EN 60068-2-6 / EN 60068-2-27
EMC Immunity / Emission Conforms to EN 61000-6-2 / EN 61000-6-4
Protection Rating IP65 / IP66 / IP67 (conforms to EN 60529)
Weight Approx. 165 g

Connections and Interfaces

Connection Type Interface Style Function
Bus Interface 2 x M8 socket, shielded, screw type EtherCAT input and downstream extension
Output Connections 2 x D-sub socket, 9-pin 16 digital outputs for actuator/valve terminals
Power Supply Feed 1 x M8 male socket, 4-pin Incoming control and auxiliary power (Us/Up)
Power Supply Downstream 1 x M8 female socket, 4-pin Power distribution loop-through to adjacent modules

Installation Guidelines

  • Mounting: Install directly onto flat machine structures or profiles using integrated mounting holes. Variable mounting positions are supported.
  • Shielding & Grounding: Ensure proper connection of the shielded M8 EtherCAT cables to achieve reliable grounding and maintain full EMC compliance.
  • Cable Routing: Keep communication cabling and high-power actuator lines separated where possible to avoid electrical interference.
  • Environmental Protection: To maintain the IP65/66/67 protection rating, ensure all unused M8 and D-sub ports are sealed with appropriate protective caps.

Compliance and Certifications

  • CE
  • UL
Loading product navigation…

What type of connection interface does the EP2816-0010 use for outputs?

The EP2816-0010 features two 9-pin D-sub sockets, making it highly suitable for direct integration with multi-pin valve manifolds and valve terminals.

What is the maximum output current supported per channel?

Each digital output channel supports a maximum current of 0.5 A. All channels are individually short-circuit proof, and the total sum current limit across all outputs is 4.0 A.

Does this EtherCAT Box support Distributed Clocks (DC)?

Yes, the EP2816-0010 has native support for Distributed Clocks, enabling high-precision, synchronized execution of digital outputs.

What is the environmental ingress protection rating of the EP2816-0010?

The module is rated for IP65, IP66, and IP67 protection according to EN 60529, allowing direct, cabinet-free mounting in wet, dusty, and demanding industrial environments.

Expédition express mondiale

  • Livraison standard : 4 à 6 jours ouvrables via DHL, FedEx et UPS.
  • Expédition express : Expédition le jour même pour les commandes en stock passées avant 14h00 (GMT+8).
  • Couverture mondiale : Service dans plus de 150 pays, avec livraison rapide en Arabie Saoudite et aux Émirats arabes unis.

Retours et garantie

  • Garantie de 30 jours : Retours acceptés pour les produits en stock dans leur emballage d’origine scellé en usine.
  • Garantie de 12 mois : Chaque composant industriel est couvert par notre garantie technique professionnelle.

Les commandes sont traitées et livrées du lundi au vendredi (hors jours fériés).


Pour connaître les conditions d’éligibilité complètes, les frais de restockage et les détails des retours internationaux, veuillez consulter notre site officiel Politique de remboursement et de retour .

TECHNICAL SPECIFICATIONS

Country of origin
Allemagne

Produits récemment consultés

Connaissances techniques

Logique booléenne avancée avec la programmation FBD PLC : applications industrielles pratiques au-delà de la logique de base

L'article explique plusieurs fonctions avancées de logique booléenne utilisées en programmation d'automates programmables industriels (API) au-delà des opérations de base ET, OU et NON. Il aborde...

Logique booléenne en programmation PLC : comprendre les portes logiques FBD

La logique booléenne est la base de tout programme PLC. Des commandes machines simples aux systèmes d'automatisation industrielle complexes, les portes logiques déterminent comment les contrôleurs...

Guide approfondi sur les pare-feux industriels et la segmentation des réseaux OT

Les pare-feux industriels jouent un rôle crucial dans la cybersécurité OT, protégeant les réseaux PLC, DCS et SCADA grâce à la segmentation, au contrôle des entrées/sorties et à l'intégration IDS/IPS...

Guide des préhenseurs robotiques : de la manipulation délicate à l'automatisation lourde

Les pinces robotiques modernes évoluent au-delà des mâchoires mécaniques traditionnelles. Des systèmes adhésifs inspirés du gecko et des pinces souples de qualité alimentaire aux outils d'entrepôt...

Retour en arrière : comment les premiers moteurs électriques ont transformé l'exploitation minière souterraine

Des compresseurs à courant continu entraînés par corde aux wagonnets de mine alimentés par batterie, les premières opérations minières ont marqué un tournant dans l’électrification industrielle. Cet...

Factory I/O : un outil moderne de simulation PLC pour la formation à l'automatisation industrielle

Factory I/O révolutionne l'enseignement des automates programmables industriels (API) en proposant des simulations industrielles 3D immersives pour les étudiants, les ingénieurs et les équipes de...