Direct field connection of decentralized actuators is managed reliably by the Beckhoff EPP2008-0022, an IP67-rated EtherCAT P Box engineered for high-performance automation networks. By integrating control signal data and power (both system voltage Us and auxiliary peripheral voltage Up) into a single, specialized cable, this module eliminates the need for external distribution enclosures. The unit features eight independent digital outputs delivering 24 V DC to handle ohmic, inductive, and lamp loads, making it ideal for severe industrial processing environments.

Features

  • One-Cable Automation: Combines high-speed EtherCAT communication and power supply over a single P-coded M8 connector interface.
  • High Channel Density: 8 digital outputs housed in a compact, ruggedized field module.
  • Individual Channel Protection: Every output channel is individually short-circuit proof with immediate overload detection.
  • Robust Load Compatibility: Capable of switching resistive (ohmic), inductive, and lamp loads up to 0.5 A per channel.
  • Environmental Resilience: Hermetically sealed IP65, IP66, and IP67 protective rating allows direct machine mounting without protective enclosures.

Applications

  • Decentralized robotics assembly cells and end-of-arm tooling.
  • Conveyor systems and high-speed material handling sortation networks.
  • Pneumatic valve manifold control and solenoid actuator switching.
  • Automotive assembly lines requiring direct tool-mounted IP67-rated I/O distribution.

Technical Specifications

Parameter Specification Value
Manufacturer Beckhoff
Model Number EPP2008-0022
Communication Protocol EtherCAT
Bus Interface 2 x M8 socket, shielded, screw-type, P-coded
Number of Outputs 8 digital outputs
Output Connections M12 x 1, 5-pin, A-coded (1 output per M12 connector)
Nominal Output Voltage 24 V DC (-15 percent / +20 percent)
Max. Output Current 0.5 A per channel (individually short-circuit proof, total sum limit 3.0 A)
Short-Circuit Current Limit Max. 1.5 A
Switching Times Typical TON: 60 us, typical TOFF: 300 us
Current Consumption (Us) Typical 100 mA
Auxiliary Current (Up) Typical 20 mA + load current
Electrical Isolation 500 V
Operating Temperature -25 to +60 degC
Storage Temperature -40 to +85 degC
Protection Rating IP65 / IP66 / IP67 (conforms to EN 60529)
Vibration/Shock Resistance Conforms to EN 60068-2-6 / EN 60068-2-27
EMC Conformity Conforms to EN 61000-6-2 / EN 61000-6-4
Approvals CE, UL
Unit Weight Approx. 250 g
Shipping Weight (Calculated) 2.0 kg
Package Dimensions (Calculated) 180 x 120 x 80 mm

Connections and Interfaces

Port / Connector Interface Type Pin Mapping & Assignment
EtherCAT P Input M8, female, 4-pin, P-coded Pin 1: Tx+ / Us+ | Pin 2: Rx+ / Up+ | Pin 3: Rx- / Up- | Pin 4: Tx- / Us-
EtherCAT P Output M8, male, 4-pin, P-coded Downstream line feed with data forwarding and Us/Up power loop-through
Channels 1 to 8 M12, 5-pin, A-coded Pin 1: Up (+24 V DC auxiliary output) | Pin 3: GND | Pin 4: Output signal | Pins 2 & 5: Functional Earth / Shield

Empirical Engineering Insights

Alternative Models & Compatibility

The EPP2008-0022 utilizes EtherCAT P technology, combining data and power. It is fundamentally different from standard EP2008 series boxes, which run on standard EtherCAT and require independent 24 V DC auxiliary power lines. Note that integration within your TwinCAT development environment requires TwinCAT 3.1 Build 4022 or higher. If migrating from older EP modules, verify that your network couplers or master terminals support EtherCAT P physical layers (e.g., EK1300 or EK1322).

Application Pitfalls & Engineering Notes

Because EtherCAT P supplies both the sensor/logic circuit (Us) and peripheral actuator loads (Up) over a single P-coded cable, cumulative current limits must be carefully planned. The absolute continuous current limit for the P-coded M8 bus connector is 3 A. Running eight high-power inductive loads at the full 0.5 A capacity will exceed the loop-through rating of downstream units, causing severe voltage drops and thermal stress on downstream boxes.

Commissioning & Wiring Tips

Always use fully shielded, industrial-grade M8 P-coded cabling to ensure electromagnetic immunity in noisy motor-drive environments. When terminating M12 ports, utilize a calibrated torque wrench to ensure tight sealing to 0.6 Nm; over-tightening or loose installation compromises the IP67 integrity and will lead to moisture ingress. Utilize TwinCAT's built-in EtherCAT P diagnostics window to monitor live voltage drops for both Us and Up power branches during full load operation.

Installation Guidelines

CRITICAL WARNING: De-energize all primary, auxiliary, and network power sources before initiating installation. Failure to disconnect system (Us) and peripheral (Up) power prior to wiring or module removal can result in hardware destruction or unexpected physical operation of associated field actuators.
1
Mount the EPP2008-0022 directly to the machine structure using M3 mounting bolts tightened to a maximum torque of 0.5 Nm. Ensure the mounting surface is flat to avoid structural strain on the housing.
2
Connect the incoming EtherCAT P M8 line to the "EtherCAT P In" port and verify the physical P-coding alignment key to avoid forcing the pins.
3
Route outgoing digital actuator lines using M12 cables. Plug unused M12 and M8 ports with genuine industrial sealing caps to guarantee the overall IP67 protection rating.
Loading product navigation…

What is the primary difference between Beckhoff EP2008 and EPP2008-0022?

The EPP2008-0022 uses EtherCAT P technology, combining communications and power (both Us and Up) on a single M8 cable. Standard EP2008 modules require separate power cables for communications and field IO power.

Can I mix standard EtherCAT and EtherCAT P modules on the same segment?

No, you cannot connect them directly on the same branch. You must use an EtherCAT P junction box, such as the EP9224-0037 or EK1310, to bridge standard EtherCAT networks to EtherCAT P segments.

What is the maximum total output current allowed for the EPP2008-0022?

While each of the 8 channels can switch up to 0.5 A, the total sum current across all outputs must not exceed 3.0 A due to physical terminal limits.

How does the short-circuit protection behave under overload conditions?

Each channel is individually protected. If a short-circuit occurs on a channel, it will limit the current to approximately 1.5 A and diagnostic status bits will flag the error state in your controller.

Expédition express mondiale

  • Livraison standard : 4 à 6 jours ouvrables via DHL, FedEx et UPS.
  • Expédition express : Expédition le jour même pour les commandes en stock passées avant 14h00 (GMT+8).
  • Couverture mondiale : Service dans plus de 150 pays, avec livraison rapide en Arabie Saoudite et aux Émirats arabes unis.

Retours et garantie

  • Garantie de 30 jours : Retours acceptés pour les produits en stock dans leur emballage d'origine scellé en usine.
  • Garantie de 12 mois : Chaque composant industriel est couvert par notre garantie technique professionnelle.

Les commandes sont traitées et livrées du lundi au vendredi (hors jours fériés).


Pour connaître l'éligibilité complète, les frais de restockage et les détails des retours internationaux, veuillez consulter notre site officiel Politique de remboursement et de retour .

TECHNICAL SPECIFICATIONS

Country of origin
Allemagne

Produits récemment consultés

Connaissances techniques

Actionneurs électriques conçus pour remplacer les systèmes à fluide : un guide pratique d'automatisation industrielle

Cet article explique comment les actionneurs électriques intégrés, tels que la série e-Actuator de SMC, transforment le contrôle du mouvement industriel en remplaçant les systèmes pneumatiques et...

Opérations mathématiques avec OpenPLC pour les applications d'automatisation industrielle

Cet article explique comment les systèmes PLC réalisent des opérations mathématiques de base telles que l'addition, la soustraction, la multiplication, la division, le modulo et l'exponentiation dans...

Logique booléenne avancée avec la programmation FBD PLC : applications industrielles pratiques au-delà de la logique de base

L'article explique plusieurs fonctions avancées de la logique booléenne utilisées en programmation d'automates programmables industriels (API) au-delà des opérations de base ET, OU et NON. Il aborde...

Logique booléenne en programmation PLC : comprendre les portes logiques FBD

La logique booléenne est la base de tout programme PLC. Des commandes machines simples aux systèmes d'automatisation industrielle complexes, les portes logiques déterminent comment les contrôleurs...

Guide approfondi sur les pare-feux industriels et la segmentation des réseaux OT

Les pare-feux industriels jouent un rôle crucial dans la cybersécurité OT, protégeant les réseaux PLC, DCS et SCADA grâce à la segmentation, au contrôle des entrées/sorties et à l’intégration IDS/IPS...

Guide des pinces robotiques : de la manipulation délicate à l'automatisation lourde

Les pinces robotiques modernes évoluent au-delà des mâchoires mécaniques traditionnelles. Des systèmes adhésifs inspirés des geckos aux pinces souples de qualité alimentaire, en passant par des...