1 of 1

EQ2008-0002 | BECKHOFF | Boîtier EtherCAT

EQ2008-0002 | BECKHOFF | Boîtier EtherCAT

Il ne reste que 10 article(s) en stock
  • Fabricant : BECKHOFF

  • N° de produit : EQ2008-0002

  • Pays d'origine :Allemagne

  • Type de produit : Boîtier EtherCAT

  • Paiement : Virement bancaire, Western Union

  • Poids : 500g

  • Dimensions : 39 mm x 160 mm x 43 mm

  • Port d'expédition : Xiamen

  • Garantie : 12 mois

Quantité
Voir les détails complets

Description

For demanding applications requiring high hygiene standards and environmental resistance, the Beckhoff EQ2008-0002 EtherCAT Box offers direct processing of eight digital outputs in a robust, stainless steel enclosure. This distributed I/O device is designed for decentralized installation directly on machinery, bypassing the need for protective control cabinets. Operating on the high-performance EtherCAT protocol, it controls digital actuators such as solenoid valves, contactors, and small lamps. With an IP69K protection rating, it is engineered to withstand high-pressure washdown environments, making it suitable for food, beverage, pharmaceutical, and chemical processing facilities.

Features

  • Hygienic Design: Durable stainless steel housing designed to resist aggressive cleaning agents and minimize bacterial accumulation.
  • 8 Digital Outputs: Standard 24 V DC outputs designed to switch ohmic, inductive, and lamp loads.
  • Short-Circuit Protection: Each channel is individually protected against short circuits to prevent module damage and minimize downtime.
  • Standard M12 Interfaces: Uses standard M12 x 1, 5-pin, A-coded sockets for reliable, watertight sensor/actuator connections.
  • Robust EtherCAT Link: Employs shielded, screw-type M8 sockets to ensure high-speed, noise-immune industrial communication.

Applications

  • Food processing and beverage bottling plants
  • Pharmaceutical manufacturing and packaging systems
  • Chemical dosing and processing equipment
  • Splash-zone industrial machinery and high-humidity environments

Technical Specifications

Parameter Value
Manufacturer Beckhoff
Model Number EQ2008-0002
Protocol EtherCAT
Number of Outputs 8
Rated Load Voltage 24 V DC (-15% / +20%)
Max. Output Current 0.5 A per channel (Sum total: 4.0 A max)
Load Types Ohmic, inductive, lamp load
Switching Times Typical TON: 50 microseconds, TOFF: 100 microseconds
Electrical Isolation 500 V
Current Consumption (from US) Typical 130 mA
Auxiliary Power Current Typical 20 mA + load
Housing Material Stainless steel
Protection Rating IP69K (conforms to EN 60529)
Operating Temperature -25 degC to +60 degC
Storage Temperature -40 degC to +85 degC
Dimensions (W x H x D) 39 mm x 160 mm x 43 mm
Vibration/Shock Resistance Conforms to EN 60068-2-6 / EN 60068-2-27
Shipping Weight (Calculated) 2.0 kg

Connections and Interfaces

Interface Connection Connector Type Assignment & Function
EtherCAT Bus Input/Output 2 x M8 socket, shielded, screw-type High-speed industrial Ethernet communication path
Digital Outputs 8 x M12 sockets, 5-pin, A-coded Channel-specific actuator connection, 24 V DC
Power Feed 1 x M8 male socket, 4-pin Main control voltage supply input
Downstream Power 1 x M8 female socket, 4-pin Power distribution link to downstream modules

Empirical Engineering Insights

Alternative Models & Compatibility

The EQ2008-0002 serves as a direct stainless steel upgrade to the standard plastic-housing EP2008-0002. While both modules operate on identical TwinCAT configuration frameworks and share matching communication diagnostics, the EQ series utilizes unique physical mount spacing and stainless-steel ground contacts. Ensure that the TwinCAT System Manager hardware tree is configured specifically for the EQ-designated variant to guarantee accurate process image diagnostic flags.

Application Pitfalls & Engineering Notes

Because the stainless steel enclosure is fully sealed to achieve an IP69K rating, thermal dissipation occurs solely through conduction and passive convection across the metal frame. When installing inside tight, enclosed areas with an ambient temperature approaching 60 degC, ensure that the total cumulative load current does not continuously sit at the absolute thermal limit of 4.0 A. Operating under high continuous loads in high ambient temperatures may trigger temporary thermal self-protection on specific output channels.

Commissioning & Wiring Tips

To maintain the IP69K structural integrity over years of operational washdowns, always use IP69K-rated cordsets that feature stainless steel hexagonal nuts. Tighten the M12 and M8 connections using a calibrated torque wrench set to the exact OEM specification. Under-tightening compromises the moisture seal, while over-tightening can deform the internal O-ring, leading to micro-fissure water ingress during temperature cycling.

Installation Guidelines

CRITICAL WARNING: Disconnect and lock out all electrical power sources before commencing physical mounting or terminal adjustments. Ensure the 24 V DC auxiliary and bus power links are entirely de-energized to prevent accidental short-circuits or damage to delicate transceiver components.
1
Mount the module to a flat, vibration-resistant machine frame using two M5 screws through the designated stainless steel fixing lugs.
2
Ensure direct metallic contact between the module mounting lugs and the machine chassis to guarantee a low-impedance ground reference path.
3
Attach the M8 EtherCAT communication cables to the shielded bus interfaces, ensuring proper alignment of the indexing pins before securing the screw rings.
4
Connect the actuator field devices to the 8 x M12 sockets and seal any unused channels with watertight protective caps to maintain the IP69K rating.
Loading product navigation…

What is the primary difference between the Beckhoff EQ2008-0002 and the standard EP2008-0002?

The EQ2008-0002 features a high-grade stainless steel housing with an IP69K rating for hygienic applications, whereas the EP2008-0002 utilizes a standard plastic housing rated for IP67. Both use identical twin-channel processing logic.

How is the short-circuit protection handled on the EQ2008-0002?

Each digital output channel is individually short-circuit proof. If a short circuit occurs on one channel, only that specific loop is shut down, while the remaining channels continue to function normally. System diagnostic data is sent back via EtherCAT.

Does this module require a specialized protective enclosure for food processing washdown zones?

No. The IP69K ingress protection and stainless steel design permit mounting directly on the machine frame without an enclosure, even in splash and high-pressure washdown areas.

What is the cumulative output limit for the EQ2008-0002?

While each individual channel supports a nominal current rating of 0.5 A, the aggregate sum current across all eight output channels must not exceed 4.0 A.

Expédition express mondiale

  • Livraison standard : 4 à 6 jours ouvrables via DHL, FedEx et UPS.
  • Expédition express : Expédition le jour même pour les commandes en stock passées avant 14h00 (GMT+8).
  • Couverture mondiale : Service dans plus de 150 pays, avec livraison rapide en Arabie Saoudite et aux Émirats arabes unis.

Retours et garantie

  • Garantie de 30 jours : Retours acceptés pour les produits en stock dans leur emballage d'origine scellé en usine.
  • Garantie de 12 mois : Chaque composant industriel est couvert par notre garantie technique professionnelle.

Les commandes sont traitées et livrées du lundi au vendredi (hors jours fériés).


Pour connaître l'éligibilité complète, les frais de restockage et les détails des retours internationaux, veuillez consulter notre site officiel Politique de remboursement et de retour .

TECHNICAL SPECIFICATIONS

Country of origin
Allemagne

Produits récemment consultés

Connaissances techniques

Actionneurs électriques conçus pour remplacer les systèmes à fluide : un guide pratique d'automatisation industrielle

Cet article explique comment les actionneurs électriques intégrés, tels que la série e-Actuator de SMC, transforment le contrôle du mouvement industriel en remplaçant les systèmes pneumatiques et...

Opérations mathématiques avec OpenPLC pour les applications d'automatisation industrielle

Cet article explique comment les systèmes PLC réalisent des opérations mathématiques de base telles que l'addition, la soustraction, la multiplication, la division, le modulo et l'exponentiation dans...

Logique booléenne avancée avec la programmation FBD PLC : applications industrielles pratiques au-delà de la logique de base

L'article explique plusieurs fonctions avancées de la logique booléenne utilisées en programmation d'automates programmables industriels (API) au-delà des opérations de base ET, OU et NON. Il aborde...

Logique booléenne en programmation PLC : comprendre les portes logiques FBD

La logique booléenne est la base de tout programme PLC. Des commandes machines simples aux systèmes d'automatisation industrielle complexes, les portes logiques déterminent comment les contrôleurs...

Guide approfondi sur les pare-feux industriels et la segmentation des réseaux OT

Les pare-feux industriels jouent un rôle crucial dans la cybersécurité OT, protégeant les réseaux PLC, DCS et SCADA grâce à la segmentation, au contrôle des entrées/sorties et à l’intégration IDS/IPS...

Guide des pinces robotiques : de la manipulation délicate à l'automatisation lourde

Les pinces robotiques modernes évoluent au-delà des mâchoires mécaniques traditionnelles. Des systèmes adhésifs inspirés des geckos aux pinces souples de qualité alimentaire, en passant par des...