1 of 1

IP2311-B200 | Beckhoff | Boîtier de bus de terrain

IP2311-B200 | Beckhoff | Boîtier de bus de terrain

Il ne reste que 10 article(s) en stock
  • Fabricant : BECKHOFF

  • N° de produit : IP2311-B200

  • Pays d'origine :Allemagne

  • Type de produit : Boîte Fieldbus

  • Paiement : Virement bancaire, Western Union

  • Poids : 250g

  • Dimensions : 30 mm x 210 mm x 26.5 mm

  • Port d'expédition : Xiamen

  • Garantie : 12 mois

Quantité
Voir les détails complets

Description

The Beckhoff IP2311-B200 is a high-performance, distributed Lightbus fieldbus box designed to bridge local digital sensors and actuators with centralized control systems. This ruggedized I/O module integrates 4 digital inputs and 4 digital outputs within a compact, direct-to-machine mountable enclosure, eliminating the need for a separate protective control cabinet.

Operating over the proprietary Beckhoff Lightbus protocol, the module utilizes plastic optical fiber (APF) to guarantee high-speed, noise-immune communication. This fiber-optic medium ensures complete electrical isolation between the communication network and the field power, making the IP2311-B200 exceptionally resilient in high-EMC industrial environments. Designed for direct field deployment, its fully encapsulated housing carries IP65/66/67 ratings, offering robust resistance to dust, moisture, and mechanical vibration.

Features

  • 4 digital inputs (24 V DC) with a 0.2 ms hardware input filter.
  • 4 short-circuit proof digital outputs rated at 0.5 A per channel.
  • Direct Lightbus network integration using plastic optical fiber (APF).
  • Highly secure, interference-free data transmission up to 45 meters between stations.
  • M8 screw-type connectors for standard sensor and actuator connections.
  • Compact and light PA6 polyamide housing with a robust physical design.
  • Comprehensive status LEDs for local diagnostics, channel activity, and optical link status.

Applications

  • Distributed packaging machinery and materials handling systems.
  • Automotive manufacturing lines demanding high EMC immunity.
  • Water and wastewater treatment facilities with high moisture exposure.
  • Machine tool and robotic assembly cells where cabinet space is limited.

Technical Specifications

Manufacturer Beckhoff Automation
Part Number / Model IP2311-B200
Fieldbus Interface Lightbus (2 x fiber-optic sockets for ZS1020-0010 plugs)
Data Transfer Rate 2.5 Mbaud
Transmission Medium APF (plastic) optical fiber (1000 micrometers)
Distance Between Stations Up to 45 m
Number of Channels 4 inputs + 4 outputs
Digital Inputs 24 V DC, -3 to +5 V ("0" signal), 11 to 30 V ("1" signal, 6 mA, Type 2)
Input Filter Time 0.2 ms
Digital Outputs 24 V DC (-15% / +20%), 0.5 A per channel, short-circuit proof
Load Types Supported Ohmic, inductive, lamp load
Control/Supply Voltage 24 V DC (-15% / +20%) via M8 connector
Electrical Isolation Control voltage to fieldbus: Yes
Enclosure Material PA6 (polyamide)
Operating Temperature 0 to +55 degC
Storage Temperature -25 to +85 degC
Protection Rating IP65, IP66, IP67 (conforms to EN 60529)
Dimensions (W x H x D) 30 mm x 210 mm x 26.5 mm
Weight Approx. 250 g

Installation Guidelines

  • Mounting: Mount the unit directly to the machine frame or flat surface using the 2 pre-drilled 3.5 mm mounting holes designed for M3 screws.
  • Fiber-Optic Handling: Maintain the specified minimum bending radius of the APF optical fiber cables to prevent signal attenuation and physical damage.
  • Tightening Torque: Ensure M8 sensor and power connectors are tightened to the recommended torque specification to preserve the IP67 protection rating.
  • Grounding: Connect the functional ground (FE) connection to a low-impedance ground point on the machine to ensure stable internal reference potential.

Compliance and Certifications

  • CE
  • UL
  • EMC Immunity/Emission: Conforms to EN 61000-6-2 / EN 61000-6-4
  • Vibration/Shock Resistance: Conforms to EN 60068-2-6 / EN 60068-2-27

What network interface does the Beckhoff IP2311-B200 use?

The IP2311-B200 connects to the Beckhoff Lightbus system using plastic optical fiber (APF) at a transfer rate of 2.5 Mbaud.

What is the maximum distance supported between two fieldbus boxes?

The maximum distance supported between two individual stations is 45 meters using plastic optical fiber (1000 micrometers).

Can this module be mounted directly onto a machine frame without a cabinet?

Yes. The module features an IP65/IP66/IP67 rated PA6 polyamide housing, making it highly resistant to dust, liquids, and vibration, suitable for direct machine installation.

What are the electrical ratings for the digital outputs?

The digital outputs support 24 V DC with a maximum load current of 0.5 A per channel. Each output channel is individually short-circuit proof.

Expédition express mondiale

  • Livraison standard : 4 à 6 jours ouvrables via DHL, FedEx et UPS.
  • Expédition express : Expédition le jour même pour les commandes en stock passées avant 14h00 (GMT+8).
  • Couverture mondiale : Service dans plus de 150 pays, avec livraison rapide en Arabie Saoudite et aux Émirats arabes unis.

Retours et garantie

  • Garantie de 30 jours : Retours acceptés pour les produits en stock dans leur emballage d'origine scellé en usine.
  • Garantie de 12 mois : Chaque composant industriel est couvert par notre garantie technique professionnelle.

Les commandes sont traitées et livrées du lundi au vendredi (hors jours fériés).


Pour connaître l'éligibilité complète, les frais de restockage et les détails des retours internationaux, veuillez consulter notre site officiel Politique de remboursement et de retour .

TECHNICAL SPECIFICATIONS

Country of origin
Allemagne

Produits récemment consultés

Connaissances techniques

Actionneurs électriques conçus pour remplacer les fluides : tutoriel pratique

This article explains how integrated electric actuators, such as SMC’s e-Actuator series, are transforming industrial motion control by replacing traditional pneumatic and hydraulic systems. It...

Opérations mathématiques avec OpenPLC pour les applications d'automatisation industrielle

Cet article explique comment les systèmes PLC réalisent des opérations mathématiques de base telles que l'addition, la soustraction, la multiplication, la division, le modulo et l'exponentiation dans...

Logique booléenne avancée avec la programmation FBD PLC : applications industrielles pratiques au-delà de la logique de base

L'article explique plusieurs fonctions avancées de la logique booléenne utilisées en programmation d'automates programmables industriels (API) au-delà des opérations de base ET, OU et NON. Il aborde...

Logique booléenne en programmation PLC : comprendre les portes logiques FBD

La logique booléenne est la base de tout programme PLC. Des commandes machines simples aux systèmes d'automatisation industrielle complexes, les portes logiques déterminent comment les contrôleurs...

Guide approfondi sur les pare-feux industriels et la segmentation des réseaux OT

Les pare-feux industriels jouent un rôle crucial dans la cybersécurité OT, protégeant les réseaux PLC, DCS et SCADA grâce à la segmentation, au contrôle des entrées/sorties et à l’intégration IDS/IPS...

Guide des pinces robotiques : de la manipulation délicate à l'automatisation lourde

Les pinces robotiques modernes évoluent au-delà des mâchoires mécaniques traditionnelles. Des systèmes adhésifs inspirés des geckos aux pinces souples de qualité alimentaire, en passant par des...