Description

Decentralized installation in harsh environments requires robust interfaces. The Beckhoff IP3112-B528 is a high-performance Fieldbus Box designed to connect digital and analog peripheral signals directly to DeviceNet networks. It functions without requiring a protective control cabinet, utilizing standard M12 and M8 connector interfaces to distribute power and fieldbus communications. The module supports automatic baud rate detection up to 500 kbaud, streamlining commissioning and enhancing diagnostic flexibility via KS2000 configuration software or explicit messaging protocols. Built to withstand challenging plant environments, it provides reliable data transfer and localized control interface distribution.

Features

  • Direct integration into DeviceNet networks with integrated T-connector functionality.
  • Flexible I/O communication modes including polling, cyclic, bit strobe, and change of state (COS).
  • Robust IP65/66/67 housing for decentralized, cabinet-free field installation.
  • Dual-channel M12 fieldbus connections for easy loop-through topology.
  • Efficient M8 power connectors for control voltage feeding and downstream distribution.

Applications

  • Automotive assembly and welding lines.
  • Material handling and conveyor systems.
  • Food and beverage processing plants.
  • Decentralized sensor and actuator networks in high-moisture or dusty environments.

Technical Specifications

Manufacturer BECKHOFF
Part Number/Model IP3112-B528
Fieldbus Interface 1 x M12 plug (5-pin), 1 x M12 socket (5-pin) with integrated tee-connector
Data Transfer Rates Automatic detection up to 500 kbaud
Data Transfer Medium Shielded copper cable, with power supply, typ. 2 x 2 x 0.25 mm²
Control Voltage Power Supply 24 V DC (-15% / +20%)
Power Supply Connection Feed: 1 x M8 male socket (4-pin); Downstream: 1 x M8 female socket (4-pin)
Box Supply Current 45 mA + current consumption of sensors (max. 0.5 A)
Electrical Isolation Control voltage/fieldbus: 500 V
Operating Temperature 0 to +55 degC
Storage Temperature -25 to +85 degC
Vibration/Shock Resistance Conforms to EN 60068-2-6 / EN 60068-2-27
EMC Immunity/Emission Conforms to EN 61000-6-2 / EN 61000-6-4
Protection Rating IP65/66/67 (conforms to EN 60529)
Shipping Weight 2 kg

Connections and Interfaces

Interface Type Connector Description Function
Fieldbus Input 1 x M12 plug, 5-pin DeviceNet incoming communication interface
Fieldbus Output 1 x M12 socket, 5-pin DeviceNet downstream loop-through connection
Power Feed 1 x M8 male socket, 4-pin Control voltage 24 V DC input
Power Downstream 1 x M8 female socket, 4-pin Control voltage daisy-chain to next box

Installation Guidelines

  • Mounting: Mount directly onto flat machine structures using the designated mounting holes. Ensure the surface is free of debris to maintain a secure seal.
  • Wiring: Use shielded copper cabling (typically 2 x 2 x 0.25 mm²) for DeviceNet transmission to preserve signal integrity and avoid EMI.
  • Grounding: Ensure the mounting surface or functional ground connection is correctly bonded to the plant's main ground potential.
  • IP Rating: Ensure all unused M8 and M12 interfaces are fitted with IP67-rated protective caps to maintain the unit's dust and moisture ingress resistance.

Compliance and Certifications

  • CE
  • UL

What communication protocol is supported by the Beckhoff IP3112-B528?

The IP3112-B528 is designed for DeviceNet networks, supporting automatic baud rate detection up to 500 kbaud.

What are the power connections on this Fieldbus Box?

It features a 24 V DC control voltage input via a 4-pin M8 male socket, and a loop-through downstream connection via a 4-pin M8 female socket.

Can this module be mounted outside a control cabinet?

Yes, with an IP65/66/67 rating, this unit is fully protected against dust, low-pressure water jets, and temporary immersion, making it suitable for direct machine mounting.

What configurations are possible for the I/O signals?

Configuration can be completed either via the Beckhoff KS2000 software package or directly through the main PLC controller using explicit messaging.

Expédition express mondiale

  • Livraison standard : 4 à 6 jours ouvrables via DHL, FedEx et UPS.
  • Expédition express : Expédition le jour même pour les commandes en stock passées avant 14h00 (GMT+8).
  • Couverture mondiale : Service dans plus de 150 pays, avec livraison rapide en Arabie Saoudite et aux Émirats arabes unis.

Retours et garantie

  • Garantie de 30 jours : Retours acceptés pour les produits en stock dans leur emballage d'origine scellé en usine.
  • Garantie de 12 mois : Chaque composant industriel est couvert par notre garantie technique professionnelle.

Les commandes sont traitées et livrées du lundi au vendredi (hors jours fériés).


Pour connaître l'éligibilité complète, les frais de restockage et les détails des retours internationaux, veuillez consulter notre site officiel Politique de remboursement et de retour .

TECHNICAL SPECIFICATIONS

Country of origin
Allemagne

Produits récemment consultés

Connaissances techniques

Actionneurs électriques conçus pour remplacer les systèmes à fluide : un guide pratique d'automatisation industrielle

Cet article explique comment les actionneurs électriques intégrés, tels que la série e-Actuator de SMC, transforment le contrôle du mouvement industriel en remplaçant les systèmes pneumatiques et...

Opérations mathématiques avec OpenPLC pour les applications d'automatisation industrielle

Cet article explique comment les systèmes PLC réalisent des opérations mathématiques de base telles que l'addition, la soustraction, la multiplication, la division, le modulo et l'exponentiation dans...

Logique booléenne avancée avec la programmation FBD PLC : applications industrielles pratiques au-delà de la logique de base

L'article explique plusieurs fonctions avancées de la logique booléenne utilisées en programmation d'automates programmables industriels (API) au-delà des opérations de base ET, OU et NON. Il aborde...

Logique booléenne en programmation PLC : comprendre les portes logiques FBD

La logique booléenne est la base de tout programme PLC. Des commandes machines simples aux systèmes d'automatisation industrielle complexes, les portes logiques déterminent comment les contrôleurs...

Guide approfondi sur les pare-feux industriels et la segmentation des réseaux OT

Les pare-feux industriels jouent un rôle crucial dans la cybersécurité OT, protégeant les réseaux PLC, DCS et SCADA grâce à la segmentation, au contrôle des entrées/sorties et à l’intégration IDS/IPS...

Guide des pinces robotiques : de la manipulation délicate à l'automatisation lourde

Les pinces robotiques modernes évoluent au-delà des mâchoires mécaniques traditionnelles. Des systèmes adhésifs inspirés des geckos aux pinces souples de qualité alimentaire, en passant par des...