Description

Precision control of current-loop signals is a key component of modern process automation and remote I/O architectures. The Beckhoff KS4011 is a single-channel, single-ended analog output terminal designed to generate output signals in the 0 to 20 mA range with a 12-bit resolution. As part of the modular KS series, this device features a pluggable wiring level, enabling fast replacement and tool-free maintenance while maintaining consistent connection density on the DIN rail. The unit facilitates galvanic isolation up to 500 V between the internal K-bus and the output signal line, protecting upstream control controllers from field disturbances.

Features

  • Single-channel analog output with a standard 0 to 20 mA signal range.
  • 12-bit resolution provides precise signal conversion (~1.5 ms conversion time).
  • Pluggable connection level for simplified terminal replacement and reduced field wiring times.
  • Electrical isolation of 500 V (K-bus to signal voltage) for superior system reliability.
  • Compact 12 mm modular housing designed for side-by-side assembly via a double slot-and-key connection system.

Applications

  • Process loop control (e.g., modulating valves, pneumatic actuators, and positioners).
  • Variable frequency drive speed referencing via current-loop inputs.
  • Remote industrial automation configurations within oil and gas, chemical processing, and water treatment systems.
  • ATEX Zone 2 hazardous location field installations.

Technical Specifications

Parameter Specification
Manufacturer Beckhoff
Part Number/Model KS4011
Number of Outputs 1 (single-ended)
Signal Current Range 0 to 20 mA
Resolution 12 bit
Conversion Time ~ 1.5 ms
Output Error < +/-0.1 % (relative to full-scale value)
Load Resistance < 500 ohm
Power Supply 24 V DC via power contacts (alternative: 15 V DC via KL9515 power supply terminal)
Current Consumption (K-bus) typ. 60 mA
Current Consumption (Power Contacts) typ. 30 mA + load
Process Image Bit Width 1 x 16-bit data (optional 1 x 8-bit control/status)
Isolation Voltage 500 V (K-bus to signal voltage)
Operating Temperature 0 to +55 degC
Storage Temperature -25 to +85 degC
Relative Humidity 95 %, non-condensing
Vibration/Shock Resistance Conforms to EN 60068-2-6 / EN 60068-2-27
EMC Immunity/Emission Conforms to EN 61000-6-2 / EN 61000-6-4
Protection Rating IP20
Housing Material Polycarbonate
Dimensions (L x W x H) 6.8 cm x 1.2 cm x 10.0 cm
Weight 0.08 kg

Connections and Interfaces

Connection Metric Specification
Wiring Mechanism Spring actuation via screwdriver tool
Solid/Stranded Wire Section 0.08 to 1.5 mm2 (AWG 28 to 16)
Flexible Wire Section 0.14 to 1.5 mm2 (AWG 26 to 16)
Stripping Length 9 to 10 mm
Max. Power Contact Current 10 A

Installation Guidelines

  • Mount vertically or horizontally on standard 35 mm DIN rails complying with EN 60715. Ensure the interlocking mechanism is locked to prevent loose connections on the backplane.
  • Ensure all spring terminals are wired using conductors stripped to the recommended length (9 to 10 mm) to prevent exposure or poor electrical contact.
  • Before detaching the pluggable KS connection level, disconnect the power supply to prevent damage to the K-bus backplane logic.
  • Provide sufficient ventilation around the terminal cluster to maintain ambient operating temperatures within the 0 to +55 degC limits.

Compliance and Certifications

  • CE
  • UL
  • ATEX (II 3 G Ex nA IIC T4 Gc)
  • DNVGL
Loading product navigation…

What is the primary function of the Beckhoff KS4011 Bus Terminal?

The Beckhoff KS4011 is a 1-channel analog output terminal designed to convert digital process values from the K-bus backplane into an analog signal current of 0 to 20 mA at 12-bit resolution for controlling field actuators.

What is the difference between KL and KS series terminals?

Unlike the standard KL series, KS series terminals like the KS4011 feature a pluggable wiring level. This allows the terminal's wiring connection block to be easily detached from the main module housing, enabling fast replacement without rewiring.

Can the KS4011 operate on external power supply ratings lower than 24 V DC?

Yes. While the KS4011 is designed to consume 24 V DC via the integrated power contacts, it can alternatively be operated with 15 V DC when connected via a KL9515 power supply terminal.

Is the KS4011 suitable for hazardous locations?

Yes, the KS4011 is ATEX certified with the marking II 3 G Ex nA IIC T4 Gc, making it suitable for Zone 2 hazardous areas.

Expédition express mondiale

  • Livraison standard : 4 à 6 jours ouvrables via DHL, FedEx et UPS.
  • Expédition express : Expédition le jour même pour les commandes en stock passées avant 14h00 (GMT+8).
  • Couverture mondiale : Service dans plus de 150 pays, avec livraison rapide en Arabie Saoudite et aux Émirats Arabes Unis.

Retours et garantie

  • Garantie de 30 jours : Retours acceptés pour les produits en stock dans leur emballage d'origine scellé en usine.
  • Garantie de 12 mois : Chaque composant industriel est couvert par notre garantie technique professionnelle.

Les commandes sont traitées et livrées du lundi au vendredi (hors jours fériés).


Pour connaître l'éligibilité complète, les frais de restockage et les détails des retours internationaux, veuillez consulter notre site officiel Politique de remboursement et de retour .

TECHNICAL SPECIFICATIONS

Country of origin
Allemagne

Produits récemment consultés

Connaissances techniques

Actionneurs électriques conçus pour remplacer les systèmes à fluide : un guide pratique d'automatisation industrielle

Cet article explique comment les actionneurs électriques intégrés, tels que la série e-Actuator de SMC, transforment le contrôle de mouvement industriel en remplaçant les systèmes pneumatiques et...

Opérations mathématiques avec OpenPLC pour les applications d'automatisation industrielle

Cet article explique comment les systèmes PLC réalisent les opérations mathématiques de base telles que l'addition, la soustraction, la multiplication, la division, le modulo et l'exponentiation dans...

Logique booléenne avancée avec la programmation FBD PLC : applications industrielles pratiques au-delà de la logique de base

L'article explique plusieurs fonctions avancées de logique booléenne utilisées en programmation d'automates programmables industriels (API) au-delà des opérations de base ET, OU et NON. Il couvre...

Logique booléenne en programmation PLC : comprendre les portes logiques FBD

La logique booléenne est la base de tout programme PLC. Des commandes machines simples aux systèmes d'automatisation industrielle complexes, les portes logiques déterminent comment les contrôleurs...

Guide approfondi sur les pare-feux industriels et la segmentation des réseaux OT

Les pare-feux industriels jouent un rôle crucial dans la cybersécurité OT, protégeant les réseaux PLC, DCS et SCADA grâce à la segmentation, au contrôle des entrées/sorties et à l’intégration IDS/IPS...

Guide des pinces robotiques : de la manipulation délicate à l'automatisation lourde

Les pinces robotiques modernes évoluent au-delà des mâchoires mécaniques traditionnelles. Des systèmes adhésifs inspirés des geckos aux pinces souples de qualité alimentaire, en passant par les...