1 of 1

FX5U-80MT/ESS | Mitsubishi Electric | Modules CPU FX5U

FX5U-80MT/ESS | Mitsubishi Electric | Modules CPU FX5U

Il ne reste que 10 article(s) en stock
  • Fabricant : Mitsubishi Electric

  • N° de produit : FX5U-80MT/ESS

  • Pays d'origine :États-Unis

  • Type de produit : Modules CPU FX5U

  • Paiement : Virement bancaire, Western Union

  • Poids : 1200g

  • Dimensions : 305 mm x 110 mm x 100 mm

  • Port d'expédition : Xiamen

  • Garantie : 12 mois

Quantité
Voir les détails complets

Description

Designed as a high-performance control engine for the MELSEC iQ-F platform, the Mitsubishi Electric FX5U-80MT/ESS programmable logic controller offers exceptional processing speeds and integrated industrial functionalities. This module features 80 built-in I/O channels (comprising 40 source/sink 24V DC inputs and 40 source-type transistor outputs) designed to coordinate complex automation tasks. The controller incorporates native analog inputs and outputs, a dedicated RS-485 port, and an Ethernet interface to support diverse industrial communication requirements directly from the base unit without requiring additional expansion cards.

Key Features

  • High-Speed System Bus: Facilitates ultra-fast communication with extension modules, minimizing signal propagation delay.
  • Integrated Analog I/O: Built-in 2-channel analog input (0 to 10 V DC) and 1-channel analog output (0 to 10 V DC) for direct sensor and actuator interfacing.
  • Advanced Positioning: Supports built-in 4-axis positioning control with dedicated high-speed counter inputs.
  • Industrial Communications: Native RJ45 Ethernet port and screw-terminal RS-485 connection for seamless integration into factory networks.
  • SD Card Slot: Onboard memory card slot for program logging, firmware updates, and recipe management.

Applications

  • High-speed packaging and sorting machinery.
  • Multi-axis pick-and-place gantry systems.
  • Water treatment control panels with analog flow/pressure monitoring.
  • Conveyor control and material handling distribution systems.

Technical Specifications

Parameter Specification Value
Manufacturer Mitsubishi Electric
Model Family MELSEC iQ-F Series (FX5U)
Supply Voltage 100 to 240 V AC (+10% / -15%), 50/60 Hz
Power Consumption 45 W
Total Built-in I/O Points 80 points (40 inputs, 40 outputs)
Input Specifications 24 V DC, 5.3 mA (X0 to X17) / 4.0 mA (X20 and later), Sink or Source configurable
Output Specifications Transistor (Source type), 5 to 30 V DC, 0.5 A per point
Built-in Analog Inputs 2 channels (0 to 10 V DC, input resistance 115 kOhms, 12-bit resolution)
Built-in Analog Output 1 channel (0 to 10 V DC, load resistance 2 kOhms to 1 MOhms, 12-bit resolution)
Built-in Communication Ports 1x RJ45 Ethernet (100Base-TX/10Base-T), 1x RS-485 (terminal block)
Operating Temperature 0 to 55 degC (32 to 131 degF)
Country of Origin Japan
Shipping Weight (Calculated) 1.2 kg (Net), 1.45 kg (Packaged)
Package Dimensions (Calculated) 305 mm x 110 mm x 100 mm

Connections and Interfaces

Terminal Block Section Signal / Pin Assignment Wiring Description
Power Terminals L, N, PE 100 to 240 V AC supply line, neutral, and physical protective earth.
Input Terminals S/S, X0 to X47 Configure S/S terminal for sink (connected to 24V) or source (connected to 0V) operations.
Output Terminals +V0 to +V4, Y0 to Y47 Source transistor outputs. External load connected between Y terminal and 0V line.
Analog Terminals V+, V-, CH1, CH2 Voltage inputs/outputs (0 to 10 V DC) for native processing. Shielded cables required.

Empirical Engineering Insights

Alternative Models & Compatibility

This controller serves as the direct evolutionary upgrade path for legacy FX3U systems. Migration from FX3U to FX5U requires software conversion via GX Works3. Be aware that the I/O terminal block alignment and physical footprint differ from older designs; ensure layout diagrams are updated to accommodate the compact housing of the FX5U model.

Application Pitfalls & Engineering Notes

When utilizing all 40 transistor outputs under continuous maximum switching states in a fully populated cabinet, local thermal limits can be reached. Ensure the enclosure provides adequate passive ventilation or active cooling to maintain ambient temperatures below 55 degC. To prevent inductive kickback from damage, external freewheeling diodes must be mounted parallel to inductive DC loads (solenoids, contactor coils) connected to Y0-Y47.

Commissioning & Wiring Tips

To configure the sink/source digital inputs, the S/S terminal must be explicitly jumpered. Wiring S/S to 24V establishes a sink input loop, whereas wiring S/S to 0V establishes a source loop. Do not leave the S/S terminal floating. For RS-485 communications, enable the terminal resistor (110 Ohm or 330 Ohm) via the built-in switch at physical bus boundaries to prevent data reflection and signal degradation.

Installation Guidelines

CRITICAL WARNING: Disconnect all primary power before mounting, terminating, or modifying wiring on the PLC. Failure to isolate power can result in permanent equipment damage, arc flash, or personal injury. Ensure the auxiliary 24 V DC power supply is monitored and protected by an external fast-acting fuse.
1

Mount the PLC onto a standard 35mm DIN rail inside a protective, IP54-rated or better cabinet to avoid contamination from conductive dust or moisture.

2

Ensure the physical ground terminal (PE) is connected directly to the main cabinet ground bus using a short, low-impedance conductor (minimum 2 mm² copper wire).

3

Isolate high-voltage AC lines from low-voltage DC and communication pathways in separate wire ducts to avoid EMI coupling.

Loading product navigation…

What is the primary difference between the ESS suffix and default FX5U models?

The ESS suffix designates that the module features source-type transistor outputs and uses European-style terminal blocks instead of standard sink-type layouts.

Can I use the integrated analog inputs for 4-20mA current loop signals?

No. The built-in analog inputs on the base unit are designed strictly for 0 to 10 V DC voltage inputs. For 4-20mA signals, an external analog expansion adapter must be added.

Does this CPU module require a separate battery to retain programs during power outages?

No. The unit uses non-volatile Flash ROM memory to store programs and parameters indefinitely without a battery. An optional battery is available only if extensive historical log retention is required.

What software is needed to program this device?

This module is configured and programmed using GX Works3 software within the IQ Works suite.

Expédition express mondiale

  • Livraison standard : 4 à 6 jours ouvrables via DHL, FedEx et UPS.
  • Expédition express : Expédition le jour même pour les commandes en stock passées avant 14h00 (GMT+8).
  • Couverture mondiale : Service dans plus de 150 pays, avec livraison rapide en Arabie Saoudite et aux Émirats arabes unis.

Retours et garantie

  • Garantie de 30 jours : Retours acceptés pour les produits en stock dans leur emballage d'origine scellé en usine.
  • Garantie de 12 mois : Chaque composant industriel est couvert par notre garantie technique professionnelle.

Les commandes sont traitées et livrées du lundi au vendredi (hors jours fériés).


Pour connaître l'éligibilité complète, les frais de restockage et les détails des retours internationaux, veuillez consulter notre site officiel Politique de remboursement et de retour .

TECHNICAL SPECIFICATIONS

Country of origin
États-Unis

Produits récemment consultés

Connaissances techniques

Actionneurs électriques conçus pour remplacer les systèmes à fluide : un guide pratique d'automatisation industrielle

Cet article explique comment les actionneurs électriques intégrés, tels que la série e-Actuator de SMC, transforment le contrôle du mouvement industriel en remplaçant les systèmes pneumatiques et...

Opérations mathématiques avec OpenPLC pour les applications d'automatisation industrielle

Cet article explique comment les systèmes PLC réalisent des opérations mathématiques de base telles que l'addition, la soustraction, la multiplication, la division, le modulo et l'exponentiation dans...

Logique booléenne avancée avec la programmation FBD PLC : applications industrielles pratiques au-delà de la logique de base

L'article explique plusieurs fonctions avancées de la logique booléenne utilisées en programmation d'automates programmables industriels (API) au-delà des opérations de base ET, OU et NON. Il aborde...

Logique booléenne en programmation PLC : comprendre les portes logiques FBD

La logique booléenne est la base de tout programme PLC. Des commandes machines simples aux systèmes d'automatisation industrielle complexes, les portes logiques déterminent comment les contrôleurs...

Guide approfondi sur les pare-feux industriels et la segmentation des réseaux OT

Les pare-feux industriels jouent un rôle crucial dans la cybersécurité OT, protégeant les réseaux PLC, DCS et SCADA grâce à la segmentation, au contrôle des entrées/sorties et à l’intégration IDS/IPS...

Guide des pinces robotiques : de la manipulation délicate à l'automatisation lourde

Les pinces robotiques modernes évoluent au-delà des mâchoires mécaniques traditionnelles. Des systèmes adhésifs inspirés des geckos aux pinces souples de qualité alimentaire, en passant par des...