1 of 1

Unité CPU EtherNet/IP CJ2M Omron CJ2M-CPU35

Unité CPU EtherNet/IP CJ2M Omron CJ2M-CPU35

Il ne reste que 3 article(s) en stock
  • Fabricant : Omron

  • N° de produit : CJ2M-CPU35

  • Pays d'origine :Japon

  • Type de produit : Modules CPU PLC

  • Paiement : Virement bancaire, Western Union

  • Poids : 1500g

  • Dimensions : 90 mm x 75 mm x 62 mm

  • Port d'expédition : Xiamen

  • Garantie : 12 mois

Quantité
Voir les détails complets

Description

Industrial control architectures and high-speed machine networks utilize the Omron CJ2M-CPU35 Central Processing Unit to achieve seamless, integrated communications and high-speed sequence processing. Engineered for the SYSMAC CJ Series platform, this unit features an onboard EtherNet/IP interface alongside a high-density processing engine, making it a reliable choice for distributed system monitoring, packaging lines, and coordinated machine automation. With support for flexible program step configurations and expansive I/O capacities, the CPU functions efficiently as the primary node within demanding manufacturing environments.

Features

  • Integrated Communications: Built-in EtherNet/IP port supports tag data links, message communications, and direct utility connections without auxiliary cards.
  • Expansive Logic Capacity: Accommodates up to 60K steps of program capacity and 160K words of data memory allocation.
  • Scalable I/O Footprint: Manages up to 2560 I/O points and controls up to 40 modules spread across 3 expansion racks.
  • High-Speed Instruction Set: Features an execution speed rating of 0.04 microseconds for basic LD instructions, ensuring highly responsive logic execution.
  • Onboard Diagnostic Interface: Built-in USB Type-B peripheral port provides high-speed connection for system programming, monitoring, and debugging.

Applications

  • Automated Packaging Equipment: Direct control of high-speed filling, sealing, and wrapping machinery.
  • Material Handling Systems: Coordination of intelligent conveyor systems, sorters, and transfer stations.
  • Water and Wastewater Treatment: Integration of telemetry, pumping systems, and sequence controls over EtherNet/IP networks.
  • Automotive Assembly Sub-stations: Execution of critical interlocking, quality verification, and device-level monitoring.

Technical Specifications

Parameter Specification Value
Manufacturer Omron
Model Number CJ2M-CPU35
Product Series CJ2M Series (Built-in EtherNet/IP)
Program Capacity 60K steps
Data Memory Capacity 160K words (DM: 32K words, EM: 32K words x 4 banks)
I/O Capacity 2560 points
Max Mountable Units 40 Units (maximum of 3 Expansion Racks)
LD Instruction Execution 0.04 microseconds
Current Consumption 0.7 A at 5 VDC
Onboard Interfaces EtherNet/IP (RJ45), USB 2.0 (Type-B)
Dimensions (H x W x D) 90 mm x 75 mm x 62 mm
Net Weight 0.19 kg
Shipping Weight (Calculated) 1.50 kg

Connections and Interfaces

Port / Interface Functional Assignment
EtherNet/IP Port (RJ45) Industrial Ethernet communications, Tag Data Links, CX-Programmer online access, and peer-to-peer data exchange.
Peripheral Port (USB) Direct USB 2.0 programming connection (Type-B) for controller commissioning and diagnostics.
Option Board Slot Accepts serial communication boards (RS-232C or RS-422A/485) for integration with legacy field devices.

Empirical Engineering Insights

Alternative Models & Compatibility

The CJ2M-CPU35 serves as an direct functional migration path from legacy CJ1G and CJ1M CPU modules. While it maintains physical backplane compatibility with standard CJ1W I/O modules, configurations utilizing older serial networks may require an added serial option board, as serial ports are optional on this processor model compared to predecessor units.

Application Pitfalls & Engineering Notes

When configuring extensive EtherNet/IP Tag Data Links, implement network switches supporting IGMP Snooping. Without active multicast management, the network ports of adjacent devices can become saturated with unnecessary multicast packets, resulting in increased communication jitter or cyclic execution timeouts inside the CPU.

Commissioning & Wiring Tips

Always use category 5e or higher shielded twisted-pair (STP) cables with double-shielding for the built-in EtherNet/IP interface. To prevent electrical noise ingress from surrounding variable frequency drives, verify that the RJ45 shielding ground is continuous with the control panel DIN rail ground point.

Installation Guidelines

CRITICAL WARNING:

Isolate and lock out all upstream electrical power supplies prior to inserting, removing, or wiring the CPU module. Performing operations on an active backplane can cause terminal damage to the backplane connectors, corrupt internal program memory, or result in unpredictable physical machinery movements.

1
Mount the CPU module securely onto the backplane, ensuring it clicks firmly into the adjacent CJ1W power supply unit.
2
Engage the yellow slide locks located at the top and bottom of the CJ2M module to lock the structural assembly together.
3
Connect the shielded Ethernet cable to the built-in RJ45 port and verify that the cable shield is grounded correctly at the switch side.
4
Energize the power supply, establish connection using CX-Programmer via the USB interface, and configure the IP address parameters.
Loading product navigation…

Can I download programs to the CJ2M-CPU35 using standard USB cables?

Yes, this controller features an onboard USB Type-B peripheral port that allows direct connection, program download, and live diagnostics using CX-Programmer without needing a special communication card.

Does this CPU model support serial communication cards?

Yes, while it does not have onboard DB9 serial ports, it features an option board slot that accommodates CJ2M-MD21 or serial communication boards such as RS-232C or RS-422A/485 options.

How do I configure the built-in EtherNet/IP address?

The IP address is configured using the Network Configurator or CX-Programmer. You write the configuration to the unit's system settings over either the USB interface or an established Ethernet route.

What is the limitation of the data memory allocation on this unit?

It provides 160K words of data memory divided into a fixed DM bank of 32K words and four EM banks of 32K words each (EM bank 0 through 3).

Expédition express mondiale

  • Livraison standard : 4 à 6 jours ouvrables via DHL, FedEx et UPS.
  • Expédition express : Expédition le jour même pour les commandes en stock passées avant 14h00 (GMT+8).
  • Couverture mondiale : Service dans plus de 150 pays, avec livraison rapide en Arabie Saoudite et aux Émirats arabes unis.

Retours et garantie

  • Garantie de 30 jours : Retours acceptés pour les produits en stock dans leur emballage d'origine scellé en usine.
  • Garantie de 12 mois : Chaque composant industriel est couvert par notre garantie technique professionnelle.

Les commandes sont traitées et livrées du lundi au vendredi (hors jours fériés).


Pour connaître l'éligibilité complète, les frais de restockage et les détails des retours internationaux, veuillez consulter notre site officiel Politique de remboursement et de retour .

TECHNICAL SPECIFICATIONS

Country of origin
Japon

Produits récemment consultés

Connaissances techniques

Actionneurs électriques conçus pour remplacer les fluides : tutoriel pratique

This article explains how integrated electric actuators, such as SMC’s e-Actuator series, are transforming industrial motion control by replacing traditional pneumatic and hydraulic systems. It...

Opérations mathématiques avec OpenPLC pour les applications d'automatisation industrielle

Cet article explique comment les systèmes PLC réalisent des opérations mathématiques de base telles que l'addition, la soustraction, la multiplication, la division, le modulo et l'exponentiation dans...

Logique booléenne avancée avec la programmation FBD PLC : applications industrielles pratiques au-delà de la logique de base

L'article explique plusieurs fonctions avancées de la logique booléenne utilisées en programmation d'automates programmables industriels (API) au-delà des opérations de base ET, OU et NON. Il aborde...

Logique booléenne en programmation PLC : comprendre les portes logiques FBD

La logique booléenne est la base de tout programme PLC. Des commandes machines simples aux systèmes d'automatisation industrielle complexes, les portes logiques déterminent comment les contrôleurs...

Guide approfondi sur les pare-feux industriels et la segmentation des réseaux OT

Les pare-feux industriels jouent un rôle crucial dans la cybersécurité OT, protégeant les réseaux PLC, DCS et SCADA grâce à la segmentation, au contrôle des entrées/sorties et à l’intégration IDS/IPS...

Guide des pinces robotiques : de la manipulation délicate à l'automatisation lourde

Les pinces robotiques modernes évoluent au-delà des mâchoires mécaniques traditionnelles. Des systèmes adhésifs inspirés des geckos aux pinces souples de qualité alimentaire, en passant par des...