1 of 1

NXRS1201 | Omron | Unité d'entrée cellule de charge

NXRS1201 | Omron | Unité d'entrée cellule de charge

Il ne reste que 3 article(s) en stock
  • Fabricant : Omron

  • N° de produit : NXRS1201

  • Pays d'origine :Japon

  • Type de produit : Unité d'entrée cellule de charge

  • Paiement : Virement bancaire, Western Union

  • Poids : 70g

  • Dimensions : 12 mm x 100 mm x 71 mm

  • Port d'expédition : Xiamen

  • Garantie : 12 mois

Quantité
Voir les détails complets

Description

Engineered for high-speed, high-accuracy weighing applications, the Omron NX-RS1201 operates as a high-performance weight and force measurement module within the Sysmac automation platform. This high-performance module interfaces directly with strain-gauge load cells, converting raw analog force signals into highly precise digital data. Designed for seamless integration into EtherCAT and EtherNet/IP networks via NX-series coupler units, the Omron NX-RS1201 features an ultra-fast conversion cycle of 125 microseconds and a 24-bit A/D converter. Its support for Synchronous I/O refreshing allows exact timing coordination with motion control processes, making it highly effective for dynamic checkweighers, filling systems, and tension control applications.

Key Features

  • Ultra-precise 24-bit analog-to-digital conversion resolution.
  • High-speed 125-microsecond conversion cycle for real-time force measurement.
  • Flexible I/O refreshing options including Synchronous, Free-Run, and Task Period Prioritized refreshing.
  • Built-in stable 5 VDC (+/- 10%) load cell excitation voltage output.
  • Space-saving 12 mm wide profile to minimize DIN rail footprint.
  • Vibration-resistant screwless push-in clamping terminal block (16 points) for rapid field installation.

Applications

  • High-speed industrial checkweighers and packaging machinery.
  • Continuous filling, dosing, and batching systems.
  • Web tension measurement and winding control in paper and film processing.
  • Material testing machines and press-fit force monitoring systems.

Technical Specifications

Specification Parameter Value / Rating
Manufacturer Omron
Model Number NX-RS1201
Product Type Load Cell Input Unit
Number of Points 1 Channel
A/D Converter Resolution 24 bits
Conversion Cycle 125 microseconds
Input Range -5.0 to 5.0 mV/V
Input Conversion Range -5.5 to 5.5 mV/V
Load Cell Excitation Voltage 5 VDC (+/- 10%), 60 mA maximum output current
Zero / Gain Adjustment Range -5.0 to 5.0 mV/V
Nonlinearity +/-0.01% of full scale
Zero Drift +/-0.1 microvolt per degC RTI (Refer to Input)
Gain Drift +/-10 ppm per degC
Warm-Up Period 30 minutes minimum
External Connection Terminals Screwless clamping terminal block (16 terminals)
Dimensions (W x H x D) 12 mm x 100 mm x 71 mm
Product Weight 0.07 kg
Shipping Weight (Calculated) 1.00 kg (including protective packaging)
Country of Origin Japan

Empirical Engineering Insights

Alternative Models & Compatibility

The NX-RS1201 is fully integrated into the Omron Sysmac platform via NX-series Bus Couplers. When replacing legacy analog input modules, ensure that the target Sysmac Studio project configuration is updated to support this unit's 24-bit output structure. Firmware compatibility must be verified with the controller unit: an NJ-series, NX-series, or NY-series controller requires firmware version 1.10 or higher for full Synchronous I/O operational modes.

Application Pitfalls & Engineering Notes

Because of its ultra-high resolution, the 24-bit A/D converter is highly sensitive to ambient temperature changes. For applications requiring precise measurements, the module requires a full 30-minute warm-up period to stabilize thermal drift coefficients. If the control panel is located near heat-generating equipment (such as variable frequency drives or large transformers), forced ventilation is highly recommended to maintain a steady ambient temperature and prevent drift.

Commissioning & Wiring Tips

To maintain maximum measurement integrity, avoid running the load cell signal cables in parallel with high-voltage AC power lines. Utilize double-shielded, twisted-pair cables for excitation and signal paths. The cable shield must be terminated at a single point—preferably at the functional ground terminal of the NX-series system—to prevent ground loops that introduce electrical noise to the microvolt-level inputs.

Installation Guidelines

CRITICAL SAFETY WARNING

Turn off all power supplies to the PLC rack and field devices before installing, removing, or wiring the module. Failure to de-energize equipment can result in electrical shock, equipment damage, or erratic system behavior.

1
Align the guide hooks on the side of the NX-RS1201 with the adjacent module or bus coupler, then slide the unit onto the DIN rail until it clicks securely into place.
2
Strip the load cell connection wires to the recommended length (typically 8 to 10 mm) and insert them directly into the push-in screwless clamp terminals. Ensure the Excitation (+/-) and Signal (+/-) polarities match your load cell specifications.
3
Connect the functional ground wire to the designated grounding terminal and apply power to the system. Allow the unit to warm up for 30 minutes before executing the zero-point and span calibration through Sysmac Studio.

What is the resolution of the A/D converter on the NX-RS1201?

The module is equipped with a high-performance 24-bit A/D converter, providing superior resolution for microvolt-level force and weight measurement.

How fast is the conversion cycle for this load cell module?

The unit features an ultra-fast conversion cycle of 125 microseconds, making it suitable for dynamic and high-speed weighing systems.

Does this module require a specific warm-up period before calibration?

Yes, to ensure accurate measurement and minimize thermal drift errors, a minimum warm-up period of 30 minutes is required after power-up.

What type of terminals are used for field connections?

It utilizes a 16-point screwless clamping terminal block, facilitating reliable, tool-free wiring that is highly resistant to industrial vibrations.

Expédition express mondiale

  • Livraison standard : 4 à 6 jours ouvrables via DHL, FedEx et UPS.
  • Expédition express : Expédition le jour même pour les commandes en stock passées avant 14h00 (GMT+8).
  • Couverture mondiale : Service dans plus de 150 pays, avec livraison rapide en Arabie Saoudite et aux Émirats arabes unis.

Retours et garantie

  • Garantie de 30 jours : Retours acceptés pour les produits en stock dans leur emballage d'origine scellé en usine.
  • Garantie de 12 mois : Chaque composant industriel est couvert par notre garantie technique professionnelle.

Les commandes sont traitées et livrées du lundi au vendredi (hors jours fériés).


Pour connaître l'éligibilité complète, les frais de restockage et les détails des retours internationaux, veuillez consulter notre site officiel Politique de remboursement et de retour .

TECHNICAL SPECIFICATIONS

Country of origin
Japon

Produits récemment consultés

Connaissances techniques

Actionneurs électriques conçus pour remplacer les systèmes à fluide : un guide pratique d'automatisation industrielle

Cet article explique comment les actionneurs électriques intégrés, tels que la série e-Actuator de SMC, transforment le contrôle du mouvement industriel en remplaçant les systèmes pneumatiques et...

Opérations mathématiques avec OpenPLC pour les applications d'automatisation industrielle

Cet article explique comment les systèmes PLC réalisent des opérations mathématiques de base telles que l'addition, la soustraction, la multiplication, la division, le modulo et l'exponentiation dans...

Logique booléenne avancée avec la programmation FBD PLC : applications industrielles pratiques au-delà de la logique de base

L'article explique plusieurs fonctions avancées de la logique booléenne utilisées en programmation d'automates programmables industriels (API) au-delà des opérations de base ET, OU et NON. Il aborde...

Logique booléenne en programmation PLC : comprendre les portes logiques FBD

La logique booléenne est la base de tout programme PLC. Des commandes machines simples aux systèmes d'automatisation industrielle complexes, les portes logiques déterminent comment les contrôleurs...

Guide approfondi sur les pare-feux industriels et la segmentation des réseaux OT

Les pare-feux industriels jouent un rôle crucial dans la cybersécurité OT, protégeant les réseaux PLC, DCS et SCADA grâce à la segmentation, au contrôle des entrées/sorties et à l’intégration IDS/IPS...

Guide des pinces robotiques : de la manipulation délicate à l'automatisation lourde

Les pinces robotiques modernes évoluent au-delà des mâchoires mécaniques traditionnelles. Des systèmes adhésifs inspirés des geckos aux pinces souples de qualité alimentaire, en passant par des...