BECKHOFF

BECKHOFF EP3162-0002 EtherCAT Box 2-Channel Analog Input Module

SKU EP3162-0002

Disponibile
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: BECKHOFF
  • Product No.: EP3162-0002
  • Origin Germany
  • Product Type: Analog Input Modules
  • Payment: T/T, Western Union
  • Weight: 0.165 kg
  • Shipping port: Xiamen
  • Warranty: 12 months

Tags

Quantità

Product Description

Description

Processing analog signals directly in harsh field environments is simplified with the EP3162-0002 EtherCAT Box. This IP67-rated decentralized module features two highly flexible, galvanically isolated analog inputs that are software-parameterizable for either voltage (-10/0 to +10 V) or current (-20/0/4 to +20 mA) signals on a per-channel basis. By executing analog-to-digital conversion directly at the sensor location, this module minimizes signal degradation over long wire runs, enabling clean 16-bit measurement resolution across distributed fieldbus networks.

The device features dual-channel isolation to eliminate ground loop issues, making it highly reliable in electrically noisy industrial applications. Connectivity is facilitated through robust, industry-standard M12 connectors for the sensor lines and M8 connectors for the EtherCAT fieldbus and power supply daisy-chaining. With integrated Distributed Clocks (DC) support, the module guarantees precise, synchronized data acquisition across large-scale industrial machinery.

Features

  • Two single-ended, individually parameterizable analog input channels.
  • Supports standard industrial signal ranges: -10 to +10 V, 0 to 10 V, -20 to +20 mA, 0 to 20 mA, and 4 to 20 mA.
  • Complete galvanic isolation between individual input channels for high signal integrity.
  • Fast analog-to-digital conversion time of approximately 100 microseconds per channel.
  • High-precision 16-bit digital resolution (including sign).
  • Distributed Clocks (DC) support for high-fidelity clock synchronization in time-critical tasks.
  • Rugged IP65/66/67 physical housing for direct mounting outside of control cabinets.

Applications

  • Decentralized process instrumentation and sensor monitoring in heavy industrial plants.
  • Hydraulics and pneumatic system pressure, flow, and temperature tracking.
  • Machine-mount data acquisition systems in automotive assembly and packaging lines.
  • Test bench environments requiring high-speed, synchronized analog measurements.

Technical Specifications

Manufacturer Beckhoff Automation
Part Number / Model EP3162-0002
Product Type EtherCAT Box (Analog Input)
Number of Inputs 2 single-ended (galvanically isolated channels)
Signal Type (Voltage) -10/0...+10 V (parameterizable per channel)
Signal Type (Current) -20/0/4...+20 mA (parameterizable per channel)
Resolution 16 bit (including sign)
Internal Resistance > 200 kOhm (voltage) | typ. 85 Ohm + diode voltage (current)
Measurement Error < ±0.3% (relative to full scale value)
Conversion Time ~ 100 microseconds
Input Filter Limit Frequency 5 kHz
Bus Interface Connection 2 x M8 socket, shielded, screw-type
Input Connection Method M12 x 1, 5-pin, A-coded
Nominal Supply Voltage 24 V DC (-15% / +20%)
Power Connection Feed: 1 x M8 male (4-pin); Downstream: 1 x M8 female (4-pin)
Current Consumption (Us) 120 mA
Sensor Supply Us derived from auxiliary voltage, electrically isolated
Electrical Isolation 500 V (fieldbus to signal), 300 V (signal to signal)
Protection Rating IP65, IP66, IP67 (conforms to EN 60529)
Operating Temperature -25 to +60 degC
Storage Temperature -40 to +85 degC
Weight approx. 165 g
Vibration / Shock Resistance Conforms to EN 60068-2-6 / EN 60068-2-27

Connections and Interfaces

M12 Pin Connection Signal Assignment
Pin 1 +24 V DC Sensor Supply (Us)
Pin 2 Analog Input + (Voltage / Current)
Pin 3 GND Sensor Supply (Us)
Pin 4 Analog Input -
Pin 5 Shield / Functional Earth

Installation Guidelines

  • Mounting: Screw the module directly onto flat machine surfaces using the integrated mounting holes. Ensure the mounting plane is grounded.
  • Shielding: Use fully shielded M12 sensor cables and shielded M8 EtherCAT cabling to preserve signal integrity and prevent electromagnetic interference (EMI).
  • Power Daisy Chaining: When utilizing the downstream M8 power output, verify that the total current draw of downstream modules does not exceed the maximum power bus capacity.
  • Sealing: Unused M12 and M8 ports must be sealed with appropriate IP67 protection caps to maintain environmental integrity.

Compliance and Certifications

  • CE
  • UL
Shipping &amp; Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
FAQ
Can the EP3162-0002 measure both voltage and current on different channels simultaneously?
Yes, each of the two analog input channels on the EP3162-0002 can be independently parameterized via TwinCAT software. One channel can be set for voltage measurements (e.g., -10 to +10 V) while the other handles current loops (e.g., 4 to 20 mA).
What is the level of electrical isolation provided between the two input channels?
The EP3162-0002 features galvanic isolation up to 300 V between the individual input channels, as well as 500 V isolation to the EtherCAT fieldbus, minimizing the risk of ground loops.
Does this module require a control cabinet for installation?
No, with its IP65/66/67-rated enclosure, the EP3162-0002 is designed for direct machine mounting in wet, dusty, or harsh environments without needing an electrical enclosure.
Reviews

EP3162-0002

Stock &amp; lead time on request

Call
1 su 1

BECKHOFF EP3162-0002 EtherCAT Box 2-Channel Analog Input Module

Only 10 item(s) left in stock
  • Manufacturer: BECKHOFF

  • Product No.: EP3162-0002

  • Country of origin:Germany

  • Product Type: Analog Input Modules

  • Payment: T/T, Western Union

  • Weight: 165g

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantità
Visualizza dettagli completi

Product Description

Description

Processing analog signals directly in harsh field environments is simplified with the EP3162-0002 EtherCAT Box. This IP67-rated decentralized module features two highly flexible, galvanically isolated analog inputs that are software-parameterizable for either voltage (-10/0 to +10 V) or current (-20/0/4 to +20 mA) signals on a per-channel basis. By executing analog-to-digital conversion directly at the sensor location, this module minimizes signal degradation over long wire runs, enabling clean 16-bit measurement resolution across distributed fieldbus networks.

The device features dual-channel isolation to eliminate ground loop issues, making it highly reliable in electrically noisy industrial applications. Connectivity is facilitated through robust, industry-standard M12 connectors for the sensor lines and M8 connectors for the EtherCAT fieldbus and power supply daisy-chaining. With integrated Distributed Clocks (DC) support, the module guarantees precise, synchronized data acquisition across large-scale industrial machinery.

Features

  • Two single-ended, individually parameterizable analog input channels.
  • Supports standard industrial signal ranges: -10 to +10 V, 0 to 10 V, -20 to +20 mA, 0 to 20 mA, and 4 to 20 mA.
  • Complete galvanic isolation between individual input channels for high signal integrity.
  • Fast analog-to-digital conversion time of approximately 100 microseconds per channel.
  • High-precision 16-bit digital resolution (including sign).
  • Distributed Clocks (DC) support for high-fidelity clock synchronization in time-critical tasks.
  • Rugged IP65/66/67 physical housing for direct mounting outside of control cabinets.

Applications

  • Decentralized process instrumentation and sensor monitoring in heavy industrial plants.
  • Hydraulics and pneumatic system pressure, flow, and temperature tracking.
  • Machine-mount data acquisition systems in automotive assembly and packaging lines.
  • Test bench environments requiring high-speed, synchronized analog measurements.

Technical Specifications

Manufacturer Beckhoff Automation
Part Number / Model EP3162-0002
Product Type EtherCAT Box (Analog Input)
Number of Inputs 2 single-ended (galvanically isolated channels)
Signal Type (Voltage) -10/0...+10 V (parameterizable per channel)
Signal Type (Current) -20/0/4...+20 mA (parameterizable per channel)
Resolution 16 bit (including sign)
Internal Resistance > 200 kOhm (voltage) | typ. 85 Ohm + diode voltage (current)
Measurement Error < ±0.3% (relative to full scale value)
Conversion Time ~ 100 microseconds
Input Filter Limit Frequency 5 kHz
Bus Interface Connection 2 x M8 socket, shielded, screw-type
Input Connection Method M12 x 1, 5-pin, A-coded
Nominal Supply Voltage 24 V DC (-15% / +20%)
Power Connection Feed: 1 x M8 male (4-pin); Downstream: 1 x M8 female (4-pin)
Current Consumption (Us) 120 mA
Sensor Supply Us derived from auxiliary voltage, electrically isolated
Electrical Isolation 500 V (fieldbus to signal), 300 V (signal to signal)
Protection Rating IP65, IP66, IP67 (conforms to EN 60529)
Operating Temperature -25 to +60 degC
Storage Temperature -40 to +85 degC
Weight approx. 165 g
Vibration / Shock Resistance Conforms to EN 60068-2-6 / EN 60068-2-27

Connections and Interfaces

M12 Pin Connection Signal Assignment
Pin 1 +24 V DC Sensor Supply (Us)
Pin 2 Analog Input + (Voltage / Current)
Pin 3 GND Sensor Supply (Us)
Pin 4 Analog Input -
Pin 5 Shield / Functional Earth

Installation Guidelines

  • Mounting: Screw the module directly onto flat machine surfaces using the integrated mounting holes. Ensure the mounting plane is grounded.
  • Shielding: Use fully shielded M12 sensor cables and shielded M8 EtherCAT cabling to preserve signal integrity and prevent electromagnetic interference (EMI).
  • Power Daisy Chaining: When utilizing the downstream M8 power output, verify that the total current draw of downstream modules does not exceed the maximum power bus capacity.
  • Sealing: Unused M12 and M8 ports must be sealed with appropriate IP67 protection caps to maintain environmental integrity.

Compliance and Certifications

  • CE
  • UL

Can the EP3162-0002 measure both voltage and current on different channels simultaneously?

Yes, each of the two analog input channels on the EP3162-0002 can be independently parameterized via TwinCAT software. One channel can be set for voltage measurements (e.g., -10 to +10 V) while the other handles current loops (e.g., 4 to 20 mA).

What is the level of electrical isolation provided between the two input channels?

The EP3162-0002 features galvanic isolation up to 300 V between the individual input channels, as well as 500 V isolation to the EtherCAT fieldbus, minimizing the risk of ground loops.

Does this module require a control cabinet for installation?

No, with its IP65/66/67-rated enclosure, the EP3162-0002 is designed for direct machine mounting in wet, dusty, or harsh environments without needing an electrical enclosure.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
Germany

Technical knowledge

1756-L73 Firmware Upgrade Guide: v19 vs v21/v31 Decision

Replacing a 1756-L73 does not automatically mean upgrading its firmware. This guide compares v19.013, v21.011 and v31.011, focusing on project compatibility, HMI communications, legacy networks and...

Implementing 3-Switch XOR Ladder Logic with Internal Bit

Implement a 3-SPST switch XOR light circuit in LogixPro or RSLogix 500 using an internal relay bit. Includes truth tables, boolean equations, and verified.

Building a Modbus RTU Network with CompactLogix and DeltaV

Integrate Allen-Bradley CompactLogix, Caterpillar ATS, and generators into DeltaV DCS over Modbus RTU. Covers ProSoft MVI69-MCM, Miille DIN266 gateways.

ONS Instruction Not Energizing OTE in Studio 5000 Ladder Logic

ONS instruction fires but the OTE coil never latches in Studio 5000 because the one-shot is only true for one scan. Use OTL/OTU or seal-in logic instead.

Kinetix 5500 EtherNet/IP Network Switch Requirements and Topology

Configure Allen-Bradley Kinetix 5500 servo drives on EtherNet/IP. Covers CIP Sync, IEEE 1588 V2 timing, Stratix selection, DLR topology, and HMI.

Moving Average Filtering in DCS and PLC Analog Control

A moving-average filter is the sliding-window smoother most instrument engineers drop into DCS and PLC analog paths. Here is how the window works, how N and sample time set lag, and when a...