B&R

B&R 4XP0000.00-K43 X2X Link Operator Keypad Module

SKU 4XP0000.00-K43

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: B&R

  • Product No.: 4XP0000.00-K43

  • Country of origin:United States

  • Product Type: X2X keypad module 6 B&R illuminated ring keys

  • Payment: T/T, Western Union

  • Weight: 1000g

  • Shipping port: Xiamen

  • Warranty: 12 months

Technical Overview

The B&R 4XP0000.00-K43 (4XP0000.00-K43) is a ruggedized, field-level X2X Link keyboard interface module engineered for direct machine interaction and safety integration. Developed for high-visibility deployment in material handling conveyors, automotive stamping cells, and industrial food processing plants, this high-integrity HMI component provides immediate tactile control and emergency override capabilities to eliminate operator latency and prevent critical mechanical asset damage. The unit integrates 6 high-visibility, multi-colored B&R illuminated ring keys alongside a dedicated physical Emergency Stop button, housed within a robust metal frame with a clean white aluminum front foil overlay. Operating natively as an X2X Link slave node, this interface distributes real-time button actuation telemetry and localized LED states across distances up to 100 m between stations, ensuring immediate control availability on expansive factory floors.

Technical Configuration

The electrical architecture and ergonomic field layout of this keypad module focus on high-reliability control room feedback and physical durability:

  • Premium Tactile Switch Interfaces: Equipped with industrial Rafix 22FS+ series switch mechanisms featuring robust mechanical travel and highly predictable feedback profiles.

  • Variable Multicolored LED Arrays: The 6 round illuminated ring keys feature distinct, independent internal color matrices to reflect varied machine operating conditions:

    • 2 Rings: Full spectrum configuration (Red, Yellow, Green, White).

    • 3 Rings: Standard status configuration (Red, Yellow, Green).

    • 1 Ring: Special function configuration (Red, Yellow, Green, Blue).

  • Dual-Contact Emergency Safety: The integrated E-stop button features two independent, hardwired Normally Closed (NC) contacts operating on an isolated 24 VDC control loop for direct integration into safety relays.

  • Severe Environment Protection: The front face is sealed with a naturally anodized aluminum frame and polyester foil overlay, securing NEMA 250 Type 4X and IP65 protection against dust, chemical mist, and high-pressure hose water.

Technical Specifications

Parameter Specification
Model 4XP0000.00-K43
Brand B&R
Origin Austria
Bus Interface Type X2X Link Slave Node
Physical Interfaces 8-pin Male Multipoint Connector
Maximum Station Distance 100 m
Tactile Key Components 6x B&R Illuminated Ring Keys / 1x E-stop
Switch Core Hardware Rafix 22FS+ (1.30.273.511/0300)
E-Stop Contact Block 2x Normally Closed (NC) Contacts
Nominal Supply Voltage 24 VDC (+/- 25%, Galvanically Isolated)
Maximum Inrush Current 20 A for less than 1 ms
Continuous Power Consumption 240 mA
Enclosure Rating (Front / Back) IP65 / IP20 (NEMA Type 4X Front)
Operating Temperature Range 0 to 50 deg C
Maximum Operating Altitude 3000 m
Dimensions (W x H x D) 170 mm x 80 mm x 32 mm
Weight 430 g

Industrial Application FAQs

  • How should the 20 A inrush current profile impact the upstream power distribution design?

    The internal power supply circuit of the 4XP0000.00-K43 pulls a brief, intense inrush current spike up to 20 A for less than 1 ms during a cold boot power-up sequence. Upstream 24 VDC switch-mode power supplies (SMPS) or electronic circuit protectors must feature adequate overload capacity or appropriate tripping characteristics to handle this transient spike without dropping the voltage rail.

  • Can the 6 illuminated ring keys be driven directly by the user application program?

    Yes. The multi-colored LEDs embedded within the Rafix 22FS+ ring keys are completely mapped to the digital output process image of the B&R master controller via the X2X Link bus. Field engineers can write application logic in B&R Automation Studio to dynamically change key colors (e.g., green for ready, flashing yellow for warning, red for fault) based on automated process steps.

  • Is the X2X Link communication line inside this module electrically isolated?

    No. The module does not feature internal galvanic isolation for the X2X Link data lines. Ensure that the entire network share a common reference potential. When routing the 100 m bus lines across different factory zones, use shielded cables and proper ground bonding plates to counteract electromagnetic interference and ground potential differentials.


Field Engineering and Installation Directives

SAFETY LOOP COMPLIANCE: The physical Emergency Stop switch must be tested for mechanical operation and contact continuity weekly. The dual Normally Closed (NC) safety contacts must be routed directly to an approved safety evaluation relay or safety PLC, completely independent of the standard X2X Link data bus processing loop.

Panel Cutout and Gasket Seating Guide

Prepare a precise rectangular panel cutout according to the 170 mm x 80 mm dimensions. Before inserting the unit, inspect the flat neoprene sealing gasket around the inner display front for proper alignment and ensure it is entirely free of particulate debris. Insert the keypad assembly from the front of the console plate and tighten the rear retention clamps progressively to compress the gasket evenly. This step is critical to maintain the NEMA Type 4X and IP65 wash-down seal and prevent liquid entry into the internal electronics.

Multipoint Bus Wiring and Grounding

Terminate the incoming field connection via the integrated 8-pin male multipoint connector. Ensure the cable shield braid from the X2X Link network is stripped correctly and clamped firmly to the metal enclosure frame or the local cabinet functional ground (FE) rail. Keep the 24 VDC power and X2X communication signals separated from high-amperage AC contactor lines and variable frequency drive (VFD) motor output conductors inside the enclosure wire ducts to maximize signal fidelity.

 

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 1
Only 10 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Silver
Country of origin
United States

Technical knowledge

Derivative Action in PID Control Without Noise Problems

Learn what derivative action contributes to a PID loop, why it can amplify measurement noise and setpoint changes, and how filtering, sampling, and staged tests make D tuning safer.

Designing Industrial Networks That Stay Troubleshootable

A practical guide to segmenting, documenting, and testing industrial Ethernet networks so plant teams can isolate faults quickly, control change, and expand without creating fragile dependencies.

Commissioning IO-Link From Master Ports to IODD Data

Commission IO-Link systematically from master addressing and port modes through IODD selection, PLC byte mapping, parameter backups, device validation, and failure-injection tests.

PowerFlex Dynamic Braking Resistor Design and Testing

A practical PowerFlex braking guide covering regenerative energy, resistor resistance and duty cycle, thermal protection, model-specific parameters, and measured commissioning tests.

Engineering Industrial Joystick Controls for Safe Motion

An industrial joystick is only the first element in a safe motion command chain. This guide covers sensing choices, wiring, signal validation, PLC logic, restart behavior, and commissioning for...

Seeing PID Behavior Before Tuning the Loop