Bently Nevada

Bently Nevada 330101-00-25-20-12-05 3300 XL 8 mm Proximity Probe

SKU 330101-00-25-20-12-05

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Bently Nevada

  • Product No.: 330101-00-25-20-12-05

  • Country of origin:United States

  • Product Type: 3300 XL 8 mm Proximity Probe

  • Barcode: 8537101190

  • Payment: T/T, Western Union

  • Weight: 140g

  • Dimensions: 45 mm x 95 mm x 95 mm (H x W x D)

  • Shipping port: Xiamen

  • Warranty: 12 months

Description

330101-00-25-20-12-05: 3300 XL 8 mm proximity probe with a 3/8-24 UNF thread, configured with a 0.0 in unthreaded length (Option 00), 2.5 in overall case length (Option 25), 2.0 m total length (Option 20), ClickLoc connector on FluidLoc cable (Option 12), and CSA/ATEX/IECEx agency approvals (Option 05).

Unlike standard configurations that feature the default Option 02 cable, this variant is manufactured with FluidLoc cable (Option 12) which prevents oil and other process fluids from migrating through the interior of the probe cable. Additionally, the lack of a stainless steel armor jacket maintains high flexibility in tight spaces, while the Option 05 certification package ensures compliance in hazardous locations.

Features

  • 8 mm tip diameter non-contact eddy-current displacement probe
  • Fully threaded 3/8-24 UNF stainless steel probe body with 2.5 in overall case length
  • FluidLoc cable option (Option 12) prevents fluid migration through the internal probe lead
  • 2.0-meter (6.6 feet) total probe length, compatible with 3300 XL extension cables and Proximitor sensors
  • ClickLoc coaxial connector provides direct connection without a connector protector
  • Option 05 hazardous area approval package certified by CSA, ATEX, and IECEx

Applications

Typical rotating machinery protection and condition monitoring scenarios including:

  • Steam and gas turbine shaft vibration and axial position measurement
  • Compressor rotor displacement and thrust position monitoring
  • Pump shaft radial vibration and rotational speed tracking
  • Critical industrial machinery monitoring requiring high-temperature, fluid-resistant proximity probes

Ordering Information

Option Code on This SKU Description
Orderable Part Number 330101-00-25-20-12-05 3300 XL 8 mm Proximity Probe, 3/8-24 UNF thread, without armor
A - Unthreaded Length Option 00 0.0 in unthreaded length (fully threaded)
B - Overall Case Length Option 25 2.5 in overall case length
C - Total Length Option 20 2.0 meters (6.6 feet) total probe length
D - Connector and Cable-Type Option 12 Miniature coaxial ClickLoc connector, FluidLoc cable
E - Agency Approval Option 05 CSA, ATEX, IECEx Approvals

Technical Specifications

Manufacturer Bently Nevada
Part Number / Model 330101-00-25-20-12-05
Product Family / System 3300 XL 8 mm Proximity Transducer System
Probe Diameter 8 mm
Measurement Type Displacement (proximity)
Operating Principle Eddy current
Thread Size 3/8-24 UNF-2A
Unthreaded Length 0.0 in
Case Length 2.5 in
Total Length 2.0 meters (6.6 feet)
Cable Type FluidLoc coaxial cable
Connector Type Miniature coaxial ClickLoc connector
Probe Tip Material Polyphenylene sulfide (PPS)
Probe Case Material AISI 303 or 304 stainless steel (SST)
Operating Temperature -52 degC to +177 degC
Sealing Pressure Designed to seal differential pressure between tip and case (Viton O-ring seal)
Minimum Cable Bend Radius 25.4 mm (1.0 in)
Tensile Strength (Maximum) 330 N (75 lbf) probe case to lead; 270 N (60 lbf) lead to connector
Recommended Case Torque 11.2 N-m (100 in-lbf)
Maximum Rated Case Torque 33.9 N-m (300 in-lbf)
Dimensions 45 mm x 95 mm x 95 mm (H x W x D)
Weight 0.14 kg

Installation Guidelines

  • Mount the probe using the recommended probe case torque of 11.2 N-m (100 in-lbf). Do not exceed the maximum rated torque of 33.9 N-m (300 in-lbf) to prevent casing damage.
  • Maintain a minimum bend radius of 25.4 mm (1.0 in) for the coaxial cable during routing.
  • Set the probe gap to the correct calibrated value (typically 1.27 mm or 50 mils) before securing the lock nut.
  • Route the FluidLoc cable with appropriate shielding and grounding procedures to minimize electrical noise interference in the monitoring chain.
  • Avoid thread engagement lengths exceeding 14.3 mm (0.563 in) per industry standards to prevent binding.

Compliance and Certifications

  • CSA, ATEX, IECEx Approvals (Option 05) for hazardous locations

FAQ

What does the Option 12 specify on the 330101-00-25-20-12-05 proximity probe?

Option 12 indicates that this probe features a miniature coaxial ClickLoc connector with a FluidLoc cable. The FluidLoc cable is designed to prevent oil, grease, or other process fluids from migrating through the internal structure of the cable to the connection point.

What is the length configuration for the 330101-00-25-20-12-05?

This specific probe has a fully threaded body with 0.0 inches of unthreaded length (Option 00), an overall case length of 2.5 inches (Option 25), and a total cable length of 2.0 meters (Option 20).

Does this probe require a separate extension cable to connect to a Proximitor sensor?

Yes. The total probe length is 2.0 meters, which must be paired with a compatible 3300 XL extension cable to achieve the required 5-meter or 9-meter total system length for the Proximitor sensor.

What certifications are included with Option 05?

Option 05 provides hazardous area approvals certified by CSA, ATEX, and IECEx, making the probe suitable for use in designated explosive environments when installed per the factory drawings.

View all FAQs →

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

Bently Nevada 330101-00-25-20-12-05 3300 XL 8 mm Proximity Probe

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 3
Only 8 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
United States

Technical knowledge

Replacing ABB DSQC 351: Controller and Network Checks

Checks to record before replacing ABB 3HNE 00006-1 DSQC 351: controller generation, X3/X5/X20/X21 wiring, DeviceNet settings, INTERBUS mapping, and LED states.

IC693CPU360 vs IC693CPU364: Ethernet and Power Budget

Compare the IC693CPU360 and IC693CPU364 by Ethernet interface, +5 VDC load, memory, rack limits, and replacement checks.

1756-OF4 Output Wrong? Check Mode, RTB, and Scaling First

A field-first diagnostic sequence for 1756-OF4 analog output problems: channel mode, removable terminal block, scaling, and controlled electrical checks.

1746-OA8 vs 1746-OA16: Output Count and Current Limits

A direct comparison of 1746-OA8 and 1746-OA16 output count, common grouping, backplane current and temperature-derated load limits.

Replacing a 1761-NET-DNI: Capture These Settings First

A field checklist for recording the 1761-NET-DNI hardware series, firmware, EDS file, DF1 settings, DeviceNet address and messaging configuration before replacement.

EL3062 vs EL3062-0030: The Input Range Changes

The EL3062 is a 0–10 V EtherCAT terminal. The EL3062-0030 is a 0–30 V variant. This checklist covers identification, scaling and commissioning.