330102-05-30-50-02-05: 3300 XL 8 mm proximity probe, 3/8-24 UNF threaded body with stainless steel armor, Option 05 unthreaded length, Option 30 overall case length, Option 50 total system length, Option 02 miniature coaxial ClickLoc connector, and Option 05 hazardous area agency approvals.
This specific configuration includes a flexible stainless steel armor with an FEP outer jacket to protect the FEP-insulated coaxial cable from abrasion and physical damage in harsh operating environments. The 5.0 m total length of the probe is calibrated to function with a 5.0 m 3300 XL Proximitor sensor without the need for a separate extension cable, simplifying the measurement loop setup for specific machinery casings. The standard ClickLoc connector provides a secure coaxial connection without a connector protector.
| Option Segment | Code on This SKU | Meaning from Official Datasheet |
|---|---|---|
| Orderable Part Number | 330102-05-30-50-02-05 | 3300 XL 8 mm Proximity Probe, 3/8-24 UNF thread, with armor |
| A - Unthreaded Length | 05 | 0.5 in unthreaded length |
| B - Overall Case Length | 30 | 3.0 in overall case length |
| C - Total Length | 50 | 5.0 meters (16.4 feet) total length |
| D - Connector and Cable-Type | 02 | Miniature coaxial ClickLoc connector, standard cable |
| E - Agency Approval | 05 | CSA, ATEX, IECEx approvals |
| Parameter | Specification Value |
|---|---|
| Manufacturer | Bently Nevada |
| Part Number | 330102-05-30-50-02-05 |
| Product Family | 3300 XL 8 mm Proximity Transducer System |
| Thread Type | 3/8-24 UNF-2A |
| Armor Type | Flexible AISI 302 or 304 SST with FEP outer jacket |
| Unthreaded Length | 0.5 in (12.7 mm) |
| Case Length | 3.0 in (76.2 mm) |
| Total Length | 5.0 m (16.4 ft) |
| Connector Type | Miniature male coaxial ClickLoc connector |
| Cable Type | 75 Ohm triaxial, FEP insulated |
| Probe Tip Material | Polyphenylene sulfide (PPS) |
| Case Material | AISI 303 or 304 stainless steel (SST) |
| Tensile Strength | 330 N (75 lbf) probe case to probe lead |
| Weight | 0.65 kg |
| Dimensions | 11 mm x 11 mm x 5076 mm (H x W x D) |
| Operating Temperature (Probe) | -52 degC to +177 degC (-62 degF to +350 degF) |
| Operating Temperature (Cable) | -52 degC to +177 degC (-62 degF to +350 degF) |
| Target Material | AISI 4140 steel (standard calibration target) |
| Recommended Probe Case Torque | 22.6 N-m (200 in-lbf) maximum rated; 7.5 N-m (66 in-lbf) recommended first three threads |
| Agency | Certification and Standards |
|---|---|
| ATEX | II 1 G Ex ia IIC T5...T1 Ga II 1 D Ex ia IIIC T90 degC...T280 degC Dc II 3 G Ex nA IIC T5...T1 Gc II 3 G Ex ec IIC T5...T1 Gc |
| IECEx | Certified for hazardous zone environments matching ATEX classifications |
| CSA | Class I, Zone 0, AEx/Ex ia IIC T5...T1 Ga; Class I, Groups A, B, C, D; Class II, Groups E, F, G; Class III |
| CE Mark | Compliant with EMC Directive 2014/30/EU and RoHS Directive 2011/65/EU |
| SIL Rating | SIL 2 (HFT = 0), SIL 3 (HFT = 1) capability when used in safety instrumented systems |
Global Express Shipping
Returns & Warranty



330102-05-30-50-02-05: 3300 XL 8 mm proximity probe, 3/8-24 UNF threaded body with stainless steel armor, Option 05 unthreaded length, Option 30 overall case length, Option 50 total system length, Option 02 miniature coaxial ClickLoc connector, and Option 05 hazardous area agency approvals.
This specific configuration includes a flexible stainless steel armor with an FEP outer jacket to protect the FEP-insulated coaxial cable from abrasion and physical damage in harsh operating environments. The 5.0 m total length of the probe is calibrated to function with a 5.0 m 3300 XL Proximitor sensor without the need for a separate extension cable, simplifying the measurement loop setup for specific machinery casings. The standard ClickLoc connector provides a secure coaxial connection without a connector protector.
| Option Segment | Code on This SKU | Meaning from Official Datasheet |
|---|---|---|
| Orderable Part Number | 330102-05-30-50-02-05 | 3300 XL 8 mm Proximity Probe, 3/8-24 UNF thread, with armor |
| A - Unthreaded Length | 05 | 0.5 in unthreaded length |
| B - Overall Case Length | 30 | 3.0 in overall case length |
| C - Total Length | 50 | 5.0 meters (16.4 feet) total length |
| D - Connector and Cable-Type | 02 | Miniature coaxial ClickLoc connector, standard cable |
| E - Agency Approval | 05 | CSA, ATEX, IECEx approvals |
| Parameter | Specification Value |
|---|---|
| Manufacturer | Bently Nevada |
| Part Number | 330102-05-30-50-02-05 |
| Product Family | 3300 XL 8 mm Proximity Transducer System |
| Thread Type | 3/8-24 UNF-2A |
| Armor Type | Flexible AISI 302 or 304 SST with FEP outer jacket |
| Unthreaded Length | 0.5 in (12.7 mm) |
| Case Length | 3.0 in (76.2 mm) |
| Total Length | 5.0 m (16.4 ft) |
| Connector Type | Miniature male coaxial ClickLoc connector |
| Cable Type | 75 Ohm triaxial, FEP insulated |
| Probe Tip Material | Polyphenylene sulfide (PPS) |
| Case Material | AISI 303 or 304 stainless steel (SST) |
| Tensile Strength | 330 N (75 lbf) probe case to probe lead |
| Weight | 0.65 kg |
| Dimensions | 11 mm x 11 mm x 5076 mm (H x W x D) |
| Operating Temperature (Probe) | -52 degC to +177 degC (-62 degF to +350 degF) |
| Operating Temperature (Cable) | -52 degC to +177 degC (-62 degF to +350 degF) |
| Target Material | AISI 4140 steel (standard calibration target) |
| Recommended Probe Case Torque | 22.6 N-m (200 in-lbf) maximum rated; 7.5 N-m (66 in-lbf) recommended first three threads |
| Agency | Certification and Standards |
|---|---|
| ATEX | II 1 G Ex ia IIC T5...T1 Ga II 1 D Ex ia IIIC T90 degC...T280 degC Dc II 3 G Ex nA IIC T5...T1 Gc II 3 G Ex ec IIC T5...T1 Gc |
| IECEx | Certified for hazardous zone environments matching ATEX classifications |
| CSA | Class I, Zone 0, AEx/Ex ia IIC T5...T1 Ga; Class I, Groups A, B, C, D; Class II, Groups E, F, G; Class III |
| CE Mark | Compliant with EMC Directive 2014/30/EU and RoHS Directive 2011/65/EU |
| SIL Rating | SIL 2 (HFT = 0), SIL 3 (HFT = 1) capability when used in safety instrumented systems |