Bently Nevada

Bently Nevada 330104-00-07-50-02-00 3300 XL 8 mm Proximity Probe

SKU 330104-00-07-50-02-00

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Bently Nevada

  • Product No.: 330104-00-07-50-02-00

  • Country of origin:United States

  • Product Type: 3300 XL 8 mm Proximity Probe

  • Barcode: 8537101190

  • Payment: T/T, Western Union

  • Weight: 570g

  • Dimensions: 70 mm x 10 mm x 10 mm (H x W x D)

  • Shipping port: Xiamen

  • Warranty: 12 months

Description

330104-00-07-50-02-00: This 3300 XL 8 mm proximity probe features an M10 x 1 metric threaded case with integrated stainless steel armor, Option 00 fully threaded (0 mm unthreaded length), Option 07 overall case length of 70 mm, Option 50 total cable length of 5.0 meters, and Option 02 miniature ClickLoc coaxial connector without connector protector.

This non-contact eddy-current transducer is used in machinery protection systems to monitor shaft vibration, axial position, and Keyphasor references on rotating machinery with fluid-film bearings. The stainless steel armor jacket surrounds the standard 75-ohm coaxial cable, preventing mechanical cuts, pinching, and abrasion in harsh operational environments. It integrates with standard 3300 XL 5-meter Proximitor systems and matches the physical and electrical compatibility profiles of standard industrial monitoring hardware.

Features

  • M10 x 1 Metric Case: Standard metric thread structure for clean retrofitting and direct mounting on European and metric machinery.
  • 0 mm Unthreaded Option: Fully threaded steel body design (Option 00) for maximum threading depth and rigid installation support.
  • 70 mm Threaded Case Length: Long thread depth (Option 07) suitable for through-wall or bracket mounting where exact probe positioning is required.
  • 5.0-Meter Total Cable Length: Built-in 5.0-meter cable (Option 50) designed to connect directly with 5-meter Proximitor sensors without requiring an intermediate extension cable.
  • ClickLoc Coaxial Connector: Gold-plated miniature male connector (Option 02) providing a secure physical connection with minimal signal attenuation.
  • Flexible Stainless Steel Armor: Protective AISI 302/304 SST spiral armoring over a standard FEP jacket shields the cable from physical abuse.

Applications

  • Radial shaft vibration measurements on turbines, compressors, and high-speed pumps
  • Axial thrust position monitoring for rotor positioning verification
  • Speed and Keyphasor timing reference measurements on rotating components
  • Industrial installations requiring physical cable armoring against structural contact

Ordering Information

Option Segment Code on This SKU Meaning / Technical Option
Orderable Part Number 330104-00-07-50-02-00 3300 XL 8 mm proximity probe, M10 x 1 thread, with protective stainless steel armor
A - Unthreaded Length Option 00 0 mm unthreaded length (fully threaded case)
B - Overall Case Length Option 07 70 mm overall case length
C - Total Length Option 50 5.0 meters (16.4 feet) total system length
D - Connector and Cable Option 02 Miniature coaxial ClickLoc connector, standard cable
E - Agency Approval Option 00 No hazardous area agency approvals required

Technical Specifications

Manufacturer Bently Nevada (Baker Hughes)
Part Number / Model 330104-00-07-50-02-00
Probe Tip Diameter 8.0 mm (0.31 in)
Thread Size M10 x 1
Unthreaded Length 0 mm
Case Length 70 mm
Cable Length 5.0 meters (16.4 feet)
Armoring Material Flexible AISI 302 or 304 SST with FEP outer jacket
Connector Type Miniature male coaxial ClickLoc connector
Probe Case Material AISI 303 or 304 stainless steel
Probe Tip Material Polyphenylene sulfide (PPS)
Nominal DC Resistance 8.73 ohms (typical from center conductor to outer conductor)
System Compatibility Pairs directly with 3300 XL 5-meter Proximitor sensor
Operating Temperature -52 degC to +177 degC (-62 degF to +350 degF)
Probe Pressure Seal Viton O-ring differential pressure seal
Cable Bend Radius 25.4 mm (1.0 in) minimum
Tensile Strength 330 N (75 lbf) maximum probe case to lead
Dimensions 70 mm x 10 mm x 10 mm (H x W x D)
Weight 0.57 kg

Connections and Interfaces

Component Interface Type Signal/Function
Probe Tip 8.0 mm Eddy-Current Interface Non-contact gap and vibration field generation
Coaxial Cable 75 Ohm Triaxial/Coaxial FEP Signal transmission to Proximitor Sensor
Coaxial Connector Miniature Male Coaxial ClickLoc Interlocks with 5-meter Proximitor sensor or matching extension cable

Installation Guidelines

  • Torque Limits: Recommended installation mounting torque is 7.5 N-m (66 in-lbf). Do not exceed the maximum rated torque of 22.6 N-m (200 in-lbf).
  • Cable Protection: Do not bend the armored cable beyond the minimum allowable bend radius of 25.4 mm (1.0 in) to prevent damage to the inner triaxial conductors.
  • Connector Care: Ensure the ClickLoc miniature connector remains clean, free of oil or moisture, and dry during the routing process. Engage the connector lock securely by hand.
  • Thread Engagement: Ensure proper alignment with internal threads. A maximum thread engagement length of 15 mm is recommended to prevent binding.

Compliance and Certifications

  • CE compliant
  • RoHS compliant
  • API Standard 670 fully compliant when integrated within a matching 3300 XL 8 mm system

FAQ

What does the 330104-00-07-50-02-00 model code specify?

This model code specifies a Bently Nevada 3300 XL 8 mm metric probe with an M10 x 1 threaded body and stainless steel armor. It has 0 mm of unthreaded length, a 70 mm case length, 5.0 meters of total cable length, a standard miniature ClickLoc coaxial connector, and does not require hazardous area approvals.

Can I use this 5.0-meter probe with a 9-meter Proximitor sensor?

No. The 5.0-meter probe is designed specifically for use with a 5.0-meter Proximitor sensor only. Standard 3300 XL systems are matched to 5-meter or 9-meter overall electrical lengths.

What is the purpose of the armor on this proximity probe?

The stainless steel armor protects the coaxial cable from physical damage, such as pinching, crushing, or abrasion in demanding machinery environments.

What is the maximum torque for mounting this probe?

The maximum rated mounting torque for standard M10 x 1 metric forward-mounted probes is 22.6 N-m (200 in-lbf), with a recommended mounting torque of 7.5 N-m (66 in-lbf).

View all FAQs →

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

Bently Nevada 330104-00-07-50-02-00 3300 XL 8 mm Proximity Probe

Quantity
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
Reviews
1 of 3
Only 7 item(s) left in stock
Quantity
View full details

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Country of origin
United States

Technical knowledge

Replacing ABB DSQC 351: Controller and Network Checks

Checks to record before replacing ABB 3HNE 00006-1 DSQC 351: controller generation, X3/X5/X20/X21 wiring, DeviceNet settings, INTERBUS mapping, and LED states.

IC693CPU360 vs IC693CPU364: Ethernet and Power Budget

Compare the IC693CPU360 and IC693CPU364 by Ethernet interface, +5 VDC load, memory, rack limits, and replacement checks.

1756-OF4 Output Wrong? Check Mode, RTB, and Scaling First

A field-first diagnostic sequence for 1756-OF4 analog output problems: channel mode, removable terminal block, scaling, and controlled electrical checks.

1746-OA8 vs 1746-OA16: Output Count and Current Limits

A direct comparison of 1746-OA8 and 1746-OA16 output count, common grouping, backplane current and temperature-derated load limits.

Replacing a 1761-NET-DNI: Capture These Settings First

A field checklist for recording the 1761-NET-DNI hardware series, firmware, EDS file, DF1 settings, DeviceNet address and messaging configuration before replacement.

EL3062 vs EL3062-0030: The Input Range Changes

The EL3062 is a 0–10 V EtherCAT terminal. The EL3062-0030 is a 0–30 V variant. This checklist covers identification, scaling and commissioning.