Implementing 3-Switch XOR Ladder Logic with Internal Bit
Implement a 3-SPST switch XOR light circuit in LogixPro or RSLogix 500 using an internal relay bit. Includes truth tables, boolean equations, and verified.
330180-90-00: 3300 XL Proximitor Sensor, configured for a 9.0-meter system length with standard panel-mount housing and no hazardous area agency approvals. This configuration conditions and drives the proximity probe signal in machinery protection networks, outputting a continuous analog DC voltage proportional to the dynamic gap distance between the probe tip and the target material.
Unlike the 1.0-meter or 5.0-meter variants, this 9.0-meter system version matches the combined impedance requirements of 3300 XL 8 mm proximity probes and extension cables calibrated to a total 9.0-meter physical length. The integrated base plate provides galvanic isolation without separate insulating hardware, minimizing installation footprint and simplifying direct mounting to equipment panels or junction enclosures.
Typical applications include shaft vibration, axial position, and speed measurements on rotating machinery such as steam turbines, gas compressors, industrial pumps, and electric motor bearings.
| Option Code | Value on This SKU | Description / Meaning |
|---|---|---|
| Orderable Part Number | 330180-90-00 | 3300 XL Proximitor Sensor |
| A - Total Length & Mounting Option | 90 | 9.0 meters (29.5 feet) system length, panel mount |
| B - Agency Approval Option | 00 | Not required |
| Parameter | Specification |
|---|---|
| Manufacturer | Bently Nevada |
| Part Number/Model | 330180-90-00 |
| Device Type | Proximitor Sensor |
| System Compatibility | 3300 XL 8 mm Proximity Transducer System (9.0 m configuration) |
| Input | Accepts one non-contacting 3300 XL 8 mm proximity probe and extension cable |
| Power Supply Requirements | -17.5 Vdc to -26 Vdc at 12 mA maximum consumption |
| Output Signal Range | -1 to -17 Vdc (proportional to gap distance) |
| Incremental Scale Factor (ISF) | 7.87 V/mm (200 mV/mil) plus/minus 6.5 percent average over 2.0 mm (80 mil) linear range |
| Linear Range | 0.25 mm to 2.3 mm (10 mils to 90 mils) |
| Output Resistance | 50 ohms |
| Operating Temperature Range | -52 degC to +100 degC (-62 degF to +212 degF) |
| Storage Temperature Range | -52 degC to +105 degC (-62 degF to +221 degF) |
| Housing Material | A308 Aluminum |
| Dimensions | 81.3 mm x 63.5 mm x 50.8 mm (H x W x D) |
| Weight | 0.246 kg |
Install the panel-mount base directly to a flat, electrically conductive surface using the integrated mounting plate. Use standard 3-conductor shielded triad field cable (18 AWG / 1.0 mm2 recommended) to connect the terminal strips to the monitoring rack system. Ensure that the total loop length of the probe and extension cable is exactly 9.0 meters to maintain calibration with the sensor. Connectors must be kept clean, dry, and protected using connector protectors or self-fusing tape when exposed to harsh environments.
Complies with European CE Mark requirements for electromagnetic compatibility and RF/EMI immunity without the need for auxiliary metal conduit or enclosures. Complies with FCC part 15 rules.
Global Express Shipping
Returns & Warranty



330180-90-00: 3300 XL Proximitor Sensor, configured for a 9.0-meter system length with standard panel-mount housing and no hazardous area agency approvals. This configuration conditions and drives the proximity probe signal in machinery protection networks, outputting a continuous analog DC voltage proportional to the dynamic gap distance between the probe tip and the target material.
Unlike the 1.0-meter or 5.0-meter variants, this 9.0-meter system version matches the combined impedance requirements of 3300 XL 8 mm proximity probes and extension cables calibrated to a total 9.0-meter physical length. The integrated base plate provides galvanic isolation without separate insulating hardware, minimizing installation footprint and simplifying direct mounting to equipment panels or junction enclosures.
Typical applications include shaft vibration, axial position, and speed measurements on rotating machinery such as steam turbines, gas compressors, industrial pumps, and electric motor bearings.
| Option Code | Value on This SKU | Description / Meaning |
|---|---|---|
| Orderable Part Number | 330180-90-00 | 3300 XL Proximitor Sensor |
| A - Total Length & Mounting Option | 90 | 9.0 meters (29.5 feet) system length, panel mount |
| B - Agency Approval Option | 00 | Not required |
| Parameter | Specification |
|---|---|
| Manufacturer | Bently Nevada |
| Part Number/Model | 330180-90-00 |
| Device Type | Proximitor Sensor |
| System Compatibility | 3300 XL 8 mm Proximity Transducer System (9.0 m configuration) |
| Input | Accepts one non-contacting 3300 XL 8 mm proximity probe and extension cable |
| Power Supply Requirements | -17.5 Vdc to -26 Vdc at 12 mA maximum consumption |
| Output Signal Range | -1 to -17 Vdc (proportional to gap distance) |
| Incremental Scale Factor (ISF) | 7.87 V/mm (200 mV/mil) plus/minus 6.5 percent average over 2.0 mm (80 mil) linear range |
| Linear Range | 0.25 mm to 2.3 mm (10 mils to 90 mils) |
| Output Resistance | 50 ohms |
| Operating Temperature Range | -52 degC to +100 degC (-62 degF to +212 degF) |
| Storage Temperature Range | -52 degC to +105 degC (-62 degF to +221 degF) |
| Housing Material | A308 Aluminum |
| Dimensions | 81.3 mm x 63.5 mm x 50.8 mm (H x W x D) |
| Weight | 0.246 kg |
Install the panel-mount base directly to a flat, electrically conductive surface using the integrated mounting plate. Use standard 3-conductor shielded triad field cable (18 AWG / 1.0 mm2 recommended) to connect the terminal strips to the monitoring rack system. Ensure that the total loop length of the probe and extension cable is exactly 9.0 meters to maintain calibration with the sensor. Connectors must be kept clean, dry, and protected using connector protectors or self-fusing tape when exposed to harsh environments.
Complies with European CE Mark requirements for electromagnetic compatibility and RF/EMI immunity without the need for auxiliary metal conduit or enclosures. Complies with FCC part 15 rules.
Global Express Shipping
Returns & Warranty
Orders are processed and delivered Monday-Friday (excluding public holidays).
For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .
| Country of origin |
United States
|