Emerson

Emerson 1C31150G01 Ovation Pulse Accumulator Module

SKU 1C31150G01

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: Emerson
  • Product No.: 1C31150G01
  • Origin United States
  • Product Type: Pulse Accumulator Modules
  • Barcode: 8537101190
  • Payment: T/T, Western Union
  • Weight: 0.32 kg
  • Dimensions: 130 mm x 130 mm x 85 mm (H x W x D)
  • Shipping port: Xiamen
  • Warranty: 12 months

Tags

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

Emerson 1C31150G01 Ovation Pulse Accumulator Module

Quantity

Product Description

Description

The Emerson 1C31150G01 is an Ovation pulse accumulator personality module engineered to interface 5V high-speed, negative common pulse signals from field devices to the Ovation Controller. Functioning as a critical data acquisition node within the Ovation Distributed Control System (DCS), this plug-in component works in conjunction with a matching electronics module and a standard base unit. It provides a secure, low-impedance connection for field wiring while ensuring proper signal transfer to the control network. Designed for high-reliability industrial automation, the module features built-in fault tolerance and communicates directly on the I/O bus, ensuring precise pulse counting and signal integration for process monitoring.

Features

  • Supports 5V high-speed, negative common pulse signal acquisition.
  • Modular "plug-in" design allowing for quick installation into DIN rail-mounted base units.
  • Equipped with "hot swapping" capabilities to streamline maintenance without system shutdown.
  • Includes built-in Electronic ID (EID) that stores module style, group, serial number, and revision data.
  • Integrates standardized diagnostic LEDs for rapid visual status verification and troubleshooting.
  • Features a writeable surface label for clear point name identification.

Applications

  • High-speed pulse counting in industrial process control.
  • Data acquisition for continuous modulating and sequential control operations.
  • Field device integration within the Emerson Ovation Distributed Control System architecture.

Ordering Information

Part Number Description
1C31150G01 Ovation Pulse Accumulator Personality Module (5V high speed, negative common)

Technical Specifications

Parameter Specification
Manufacturer Emerson Process Management
System Compatibility Ovation Distributed Control System (DCS)
Module Type Pulse Accumulator Personality Module
Input Signal Level 5V DC
Signal Configuration High-speed, negative common
Mounting Base Unit (DIN rail mounted)
Surge Protection IEEE C37.90.1-1989 (ANSI C37.90.1-1989)

Installation Guidelines

  • Physical Separation: Maintain strict physical separation between noise-producing circuits (high-level power) and noise-sensitive signal circuits to minimize electrostatic and electromagnetic coupling.
  • Wiring Method: Use individually twisted and shielded pairs for all low-level signal connections to suppress electromagnetic interference and eliminate sensitive circuit loops.
  • Shield Grounding: Ground the signal shield at one end only, preferably at a single point near the signal source. If source grounding is not feasible, ground it at the Ovation Controller.
  • Shield Continuity: Run the shield unbroken from the field device directly to the shield terminal on the I/O base unit. Maintain shield continuity through any local junction boxes.
  • Mounting: Secure the associated base unit onto a standard DIN rail within the Ovation controller cabinet, ensuring low-impedance earth ground connections are properly terminated.

Compliance and Certifications

  • CE Mark (When installed in CE Mark certified cabinets, providing defined radiated and conducted RF immunity)
  • IEEE C37.90.1-1989 / ANSI C37.90.1-1989 (Surge Protection)
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
FAQ
What is the Emerson 1C31150G01 used for?
The Emerson 1C31150G01 is an Ovation pulse accumulator personality module used to acquire 5V high-speed, negative common pulse signals from field devices for the Ovation Distributed Control System.
Which system does the module belong to?
The module belongs to the Emerson Ovation Distributed Control System (DCS), where it interfaces field inputs directly to the Ovation Controller via the I/O bus.
What are the recommended wiring practices for this module?
For optimal noise rejection, it is highly recommended to use individually twisted and shielded cable pairs for all signal connections, with the shield grounded at a single point.
Does the module support hot swapping?
Yes. The Ovation I/O system features hot swapping capabilities, allowing engineers to replace the module without shutting down the controller or halting the process.
Does the module provide surge protection?
Yes. The module includes built-in surge protection that meets IEEE C37.90.1-1989 and ANSI C37.90.1-1989 standards.
Reviews

1C31150G01

Stock & lead time on request

Call
1 of 3

Emerson 1C31150G01 Ovation Pulse Accumulator Module

Only 3 item(s) left in stock
  • Manufacturer: Emerson

  • Product No.: 1C31150G01

  • Country of origin:United States

  • Product Type: Pulse Accumulator Modules

  • Barcode: 8537101190

  • Payment: T/T, Western Union

  • Weight: 320g

  • Dimensions: 130 mm x 130 mm x 85 mm (H x W x D)

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantity
View full details

Description

The Emerson 1C31150G01 is an Ovation pulse accumulator personality module engineered to interface 5V high-speed, negative common pulse signals from field devices to the Ovation Controller. Functioning as a critical data acquisition node within the Ovation Distributed Control System (DCS), this plug-in component works in conjunction with a matching electronics module and a standard base unit. It provides a secure, low-impedance connection for field wiring while ensuring proper signal transfer to the control network. Designed for high-reliability industrial automation, the module features built-in fault tolerance and communicates directly on the I/O bus, ensuring precise pulse counting and signal integration for process monitoring.

Features

  • Supports 5V high-speed, negative common pulse signal acquisition.
  • Modular "plug-in" design allowing for quick installation into DIN rail-mounted base units.
  • Equipped with "hot swapping" capabilities to streamline maintenance without system shutdown.
  • Includes built-in Electronic ID (EID) that stores module style, group, serial number, and revision data.
  • Integrates standardized diagnostic LEDs for rapid visual status verification and troubleshooting.
  • Features a writeable surface label for clear point name identification.

Applications

  • High-speed pulse counting in industrial process control.
  • Data acquisition for continuous modulating and sequential control operations.
  • Field device integration within the Emerson Ovation Distributed Control System architecture.

Ordering Information

Part Number Description
1C31150G01 Ovation Pulse Accumulator Personality Module (5V high speed, negative common)

Technical Specifications

Parameter Specification
Manufacturer Emerson Process Management
System Compatibility Ovation Distributed Control System (DCS)
Module Type Pulse Accumulator Personality Module
Input Signal Level 5V DC
Signal Configuration High-speed, negative common
Mounting Base Unit (DIN rail mounted)
Surge Protection IEEE C37.90.1-1989 (ANSI C37.90.1-1989)

Installation Guidelines

  • Physical Separation: Maintain strict physical separation between noise-producing circuits (high-level power) and noise-sensitive signal circuits to minimize electrostatic and electromagnetic coupling.
  • Wiring Method: Use individually twisted and shielded pairs for all low-level signal connections to suppress electromagnetic interference and eliminate sensitive circuit loops.
  • Shield Grounding: Ground the signal shield at one end only, preferably at a single point near the signal source. If source grounding is not feasible, ground it at the Ovation Controller.
  • Shield Continuity: Run the shield unbroken from the field device directly to the shield terminal on the I/O base unit. Maintain shield continuity through any local junction boxes.
  • Mounting: Secure the associated base unit onto a standard DIN rail within the Ovation controller cabinet, ensuring low-impedance earth ground connections are properly terminated.

Compliance and Certifications

  • CE Mark (When installed in CE Mark certified cabinets, providing defined radiated and conducted RF immunity)
  • IEEE C37.90.1-1989 / ANSI C37.90.1-1989 (Surge Protection)

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

Emerson 1C31150G01 Ovation Pulse Accumulator Module

What is the Emerson 1C31150G01 used for?

The Emerson 1C31150G01 is an Ovation pulse accumulator personality module used to acquire 5V high-speed, negative common pulse signals from field devices for the Ovation Distributed Control System.

Which system does the module belong to?

The module belongs to the Emerson Ovation Distributed Control System (DCS), where it interfaces field inputs directly to the Ovation Controller via the I/O bus.

What are the recommended wiring practices for this module?

For optimal noise rejection, it is highly recommended to use individually twisted and shielded cable pairs for all signal connections, with the shield grounded at a single point.

Does the module support hot swapping?

Yes. The Ovation I/O system features hot swapping capabilities, allowing engineers to replace the module without shutting down the controller or halting the process.

Does the module provide surge protection?

Yes. The module includes built-in surge protection that meets IEEE C37.90.1-1989 and ANSI C37.90.1-1989 standards.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Greyish White
Country of origin
United States
Power source
DC Power

Recently Viewed Products

Technical knowledge

Implementing 3-Switch XOR Ladder Logic with Internal Bit

Implement a 3-SPST switch XOR light circuit in LogixPro or RSLogix 500 using an internal relay bit. Includes truth tables, boolean equations, and verified.

Building a Modbus RTU Network with CompactLogix and DeltaV

Integrate Allen-Bradley CompactLogix, Caterpillar ATS, and generators into DeltaV DCS over Modbus RTU. Covers ProSoft MVI69-MCM, Miille DIN266 gateways.

ONS Instruction Not Energizing OTE in Studio 5000 Ladder Logic

ONS instruction fires but the OTE coil never latches in Studio 5000 because the one-shot is only true for one scan. Use OTL/OTU or seal-in logic instead.

Kinetix 5500 EtherNet/IP Network Switch Requirements and Topology

Configure Allen-Bradley Kinetix 5500 servo drives on EtherNet/IP. Covers CIP Sync, IEEE 1588 V2 timing, Stratix selection, DLR topology, and HMI.

Moving Average Filtering in DCS and PLC Analog Control

A moving-average filter is the sliding-window smoother most instrument engineers drop into DCS and PLC analog paths. Here is how the window works, how N and sample time set lag, and when a...

GE Mark VI Function Blocks for Gas Turbine Control Logic

On Frame 5–9 gas turbines, GE Mark VI and Mark VIe run control as function-block application software. This article maps process, protection, and sequencing functions—and what Toolbox ST access...