General Electric

General Electric IS210MVRBH1A Mark VIe I/O Interface Board

SKU IS210MVRBH1A

In stock
  • 12-month warranty
  • Free returns within 30 days
  • Manufacturer: General Electric
  • Product No.: IS210MVRBH1A
  • Origin United States
  • Product Type: I/O Interface Board
  • Barcode: 8537101190
  • Payment: T/T, Western Union
  • Weight: 1.2 kg
  • Dimensions: 37.5 cm x 24.1 cm x 8.9 cm (W x H x D)
  • Shipping port: Xiamen
  • Warranty: 12 months

Tags

Quantity

Product Description

Description

The IS210MVRBH1A is an I/O interface board designed to function seamlessly within the Mark VIe control system. This printed circuit board (PCB) serves as a dedicated communication and connectivity hub, typically operating in conjunction with the PMVE input-output pack to process analog and digital signals. To maintain system reliability, the board features an integrated temperature sensor with an accuracy of 2 Celsius. If temperatures exceed predefined thresholds, the system automatically triggers a diagnostic alarm and logs the condition into the database (signal space) to support subsequent control actions or plant messages. Because each associated I/O pack communicates independently on the IONet, the IS210MVRBH1A supports individual pack replacement without interrupting other active I/O modules or requiring the removal of existing field wiring.

Features

  • Configured specifically for R/S/T ADIO (Analog/Digital Input/Output) device interfacing.
  • Facilitates real-time, bidirectional communication and data routing within the control network.
  • Provides full compatibility with the Mark VIe control system architecture.
  • Modular engineering allows for direct hot-swapping of connected I/O packs.
  • Utilizes the Unit Data Highway (UDH) protocol for high-speed inter-module data exchange.
  • Extends overall signal, sensor, and actuator capacity when combined with PMVE packs.
  • Supports fault-tolerant architectures through integrated network-wide alerting and data processing.

Applications

  • Gas turbine control systems
  • Steam turbine monitoring and regulation
  • Distributed Control Systems (DCS) in power generation
  • Industrial automation and process control plants

Technical Specifications

Parameter Value
Manufacturer General Electric
Part Number IS210MVRBH1A
Series Mark VIe
Product Type PCB (I/O Interface Board)
Dimensions 14.75 x 9.50 x 3.50 inches
Operating Temperature -30 to 65 Celsius
Temperature Sensor Accuracy 2 Celsius (3.6 Fahrenheit for connected packs)
Communication Protocol UDH (Unit Data Highway) / IONet
Country of Manufacture United States (USA)

Installation Guidelines

  • Ensure appropriate grounding and shielding practices are maintained at the terminal board to minimize EMI/RFI interference.
  • Avoid routing high-voltage field wiring parallel to low-voltage network cables within the enclosure.
  • Rely on free convection cooling by leaving adequate ventilation space around the board assembly.
  • Connected I/O packs can be plugged in or replaced without removing the underlying field wiring from the interface board.

Compliance and Certifications

  • May comply with safety instrumented system standards such as ISA S84 or IEC 61508 depending on total system configuration.
Shipping & Returns

Global Express Shipping

  • Standard Delivery: 4–6 business days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our technical warranty.
FAQ
How does the device handle temperature anomalies?
The board features an onboard temperature sensor accurate to 2 Celsius. If excessive heat is detected, a diagnostic alarm is triggered, and the logic is saved to the system database for proactive maintenance.
Can connected components be replaced while the system is online?
Yes. Each I/O pack communicates directly on IONet, allowing independent replacement without affecting other system I/O or removing field wiring.
What is the operating temperature range for the hardware?
The interface board and its associated processor/data acquisition components are rated to operate from -30 to 65 Celsius using standard convection cooling.
Reviews

IS210MVRBH1A

Stock & lead time on request

Call
1 of 3

General Electric IS210MVRBH1A Mark VIe I/O Interface Board

Only 2 item(s) left in stock
  • Manufacturer: General Electric

  • Product No.: IS210MVRBH1A

  • Country of origin:United States

  • Product Type: I/O Interface Board

  • Barcode: 8537101190

  • Payment: T/T, Western Union

  • Weight: 1200g

  • Dimensions: 37.5 cm x 24.1 cm x 8.9 cm (W x H x D)

  • Shipping port: Xiamen

  • Warranty: 12 months

Quantity
View full details

Description

The IS210MVRBH1A is an I/O interface board designed to function seamlessly within the Mark VIe control system. This printed circuit board (PCB) serves as a dedicated communication and connectivity hub, typically operating in conjunction with the PMVE input-output pack to process analog and digital signals. To maintain system reliability, the board features an integrated temperature sensor with an accuracy of 2 Celsius. If temperatures exceed predefined thresholds, the system automatically triggers a diagnostic alarm and logs the condition into the database (signal space) to support subsequent control actions or plant messages. Because each associated I/O pack communicates independently on the IONet, the IS210MVRBH1A supports individual pack replacement without interrupting other active I/O modules or requiring the removal of existing field wiring.

Features

  • Configured specifically for R/S/T ADIO (Analog/Digital Input/Output) device interfacing.
  • Facilitates real-time, bidirectional communication and data routing within the control network.
  • Provides full compatibility with the Mark VIe control system architecture.
  • Modular engineering allows for direct hot-swapping of connected I/O packs.
  • Utilizes the Unit Data Highway (UDH) protocol for high-speed inter-module data exchange.
  • Extends overall signal, sensor, and actuator capacity when combined with PMVE packs.
  • Supports fault-tolerant architectures through integrated network-wide alerting and data processing.

Applications

  • Gas turbine control systems
  • Steam turbine monitoring and regulation
  • Distributed Control Systems (DCS) in power generation
  • Industrial automation and process control plants

Technical Specifications

Parameter Value
Manufacturer General Electric
Part Number IS210MVRBH1A
Series Mark VIe
Product Type PCB (I/O Interface Board)
Dimensions 14.75 x 9.50 x 3.50 inches
Operating Temperature -30 to 65 Celsius
Temperature Sensor Accuracy 2 Celsius (3.6 Fahrenheit for connected packs)
Communication Protocol UDH (Unit Data Highway) / IONet
Country of Manufacture United States (USA)

Installation Guidelines

  • Ensure appropriate grounding and shielding practices are maintained at the terminal board to minimize EMI/RFI interference.
  • Avoid routing high-voltage field wiring parallel to low-voltage network cables within the enclosure.
  • Rely on free convection cooling by leaving adequate ventilation space around the board assembly.
  • Connected I/O packs can be plugged in or replaced without removing the underlying field wiring from the interface board.

Compliance and Certifications

  • May comply with safety instrumented system standards such as ISA S84 or IEC 61508 depending on total system configuration.

How does the device handle temperature anomalies?

The board features an onboard temperature sensor accurate to 2 Celsius. If excessive heat is detected, a diagnostic alarm is triggered, and the logic is saved to the system database for proactive maintenance.

Can connected components be replaced while the system is online?

Yes. Each I/O pack communicates directly on IONet, allowing independent replacement without affecting other system I/O or removing field wiring.

What is the operating temperature range for the hardware?

The interface board and its associated processor/data acquisition components are rated to operate from -30 to 65 Celsius using standard convection cooling.

Global Express Shipping

  • Standard Delivery: 4-6 Business Days via DHL, FedEx, and UPS.
  • Express Dispatch: Same-day dispatch for in-stock orders placed before 2:00 PM (GMT+8).
  • Worldwide Coverage: Serving over 150 countries, including rapid delivery to Saudi Arabia and UAE.

Returns & Warranty

  • 30-Day Guarantee: Returns accepted for in-stock products in original, factory-sealed packaging.
  • 12-Month Warranty: Every industrial component is backed by our professional technical warranty.

Orders are processed and delivered Monday-Friday (excluding public holidays).


For full eligibility, restocking fees, and international return details, please view our official Refund & Return Policy .

TECHNICAL SPECIFICATIONS

Color pattern
Green
Country of origin
United States

Recently Viewed Products

Technical knowledge

Implementing 3-Switch XOR Ladder Logic with Internal Bit

Implement a 3-SPST switch XOR light circuit in LogixPro or RSLogix 500 using an internal relay bit. Includes truth tables, boolean equations, and verified.

Building a Modbus RTU Network with CompactLogix and DeltaV

Integrate Allen-Bradley CompactLogix, Caterpillar ATS, and generators into DeltaV DCS over Modbus RTU. Covers ProSoft MVI69-MCM, Miille DIN266 gateways.

ONS Instruction Not Energizing OTE in Studio 5000 Ladder Logic

ONS instruction fires but the OTE coil never latches in Studio 5000 because the one-shot is only true for one scan. Use OTL/OTU or seal-in logic instead.

Kinetix 5500 EtherNet/IP Network Switch Requirements and Topology

Configure Allen-Bradley Kinetix 5500 servo drives on EtherNet/IP. Covers CIP Sync, IEEE 1588 V2 timing, Stratix selection, DLR topology, and HMI.